Ashly CA-1.54, CA-504, CA-502, CA-1.52, CA-1.04 User Manual

...
CA SERIES
CA-502
CA-504
CA-1.02
CA-1.04
CA-1.52
2- and 4-channel
Operating Manual
Power Amplifier
1
CA Amplifier • Operating Manual
CA Amplifier • Operating Manual
Important Safety Instructions •
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. To reduce the risk of fire or
electric shock, do not expose this apparatus to rain or moisture.
6. Do not use this apparatus near
water.
7. Clean only with dry cloth.
8. Do not block any ventilation
openings. Install in accordance with the manufacturer’s instructions.
9. Do not install near any heat
sources such as radiators, heat registers, stoves, or other apparatus.
10. Do not defeat the safety
purpose of the polarized or groundingtype plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
11. Protect the power cord
from being walked on or pinched particularly at plugs,
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance instructions in the literature accompanying the device.
convenience receptacles, and the point where they exit from the apparatus.
12. Only use attachments/
accessories specified by the manufacturer.
13. Use only with the cart, stand,
tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/ apparatus combination to avoid injury from tip-over.
14. Unplug this apparatus during
lightning storms or when unused for long periods of time.
15. Refer all servicing to qualified
service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
Consignes de sécurité à lire attentivement
n’accepte pas la fiche, consulter
Le symbole de la flèche dans un triangle équilateral symbolisant la foudre est prévu pour sensibiliser l’utilisateur à la présence de tension de voltage non isolée à l’intérieur de l’appareil. Elle pourrait constituer un danger de risque de décharge élec­trique pour les utilisateurs. Le point d’excl mation dans le triangle équilatérale alerte l’utilisateur de la présence de consignes qu’il doit d’abord consulter avant d’utiliser l’appareil.
1. Lisez ces instructions.
2. Conservez ces instructions.
3. Observez les avertissements.
4. Suivez ces instructions.
5. Pour réduire le risque de feu
ou la décharge électrique, ne pas exposer cet appareil pour pleuvoir ou l’humidité.
6. Ne pas utiliser l’appareil près de
l’eau.
7. Le nettoyer à l’aide d’un tissus
sec.
8. Ne pas bloquer les ouvertures
de ventilation, installer selon les consignes du fabricant.
9. Eloigner des sources de chaleur
tel: radiateurs, fourneaux ou autres appareils qui produisent de la chaleur.
10. Ne pas modifier ou amputer
le système de la mise à terre. Une prise avec mise à terre comprend deux lames dont une plus large ainsi qu’une mise à terre: ne pas la couper ou la modifier. Si la prise murale
WARNING: THIS APPARATUS MUST BE GROUNDED (EARTHED)
un électricien pour qu’il remplace la prise désuète.
11. Protéger le cordon de secteur
contre tous bris ou pincement qui pourraient l’endommager, soit à la fiche murale ou à l’appareil.
12. N’employer que les accessoires
recommandés par le fabricant.
13. N’utiliser qu’avec les systèmes
de fixation,chariots, trépied ou autres, approuvés par le fabricant ou vendus avec l’appareil.
14. Débrancher l’appareil lors des
orages électriques ou si inutilisé pendant une longue période de temps.
15. Un entretient effectué par un
centre de service accrédité est exigé si l’appareil a été endommagé de quelque façon: si il a été exposé à la pluie,, l’humidité ou s’il ne fonctionne pas normalement ou qu’il a été échappé.
2
2
CA Amplifier • Operating Manual
FCC Compliance
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
■ This device may not cause harmful
interference
■ This device must accept any
interference received, including interference that may cause undesired operation
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in both a commercial and residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Unpacking
As a part of our system of quality control, every Ashly product is carefully inspected before leaving the factory to ensure flawless appearance.
After unpacking, please inspect for any physical damage. Save the shipping carton and all packing materials, as they were carefully designed to reduce to a minimum the possibility of transportation damage should the unit again require packing and shipping. In the event that damage has occurred, immediately notify your dealer so that a written claim to cover the damages can be initiated.
The right to any claim against a public carrier can be forfeited if the carrier is not notified promptly and if the shipping carton and packing materials are not available for inspection by the carrier. Save all packing materials until the claim has been settled.
About Ashly
Ashly Audio was founded in 1974 by a group of recording engineers, concert sound professionals, and electronics designers. The first products were elaborate custom consoles for friends and associates, but business quickly spread to new clients and the business grew.
The philosophy we established from the very beginning holds true today: to offer only the highest quality audio tools at an affordable cost to the professional user − ensuring reliability and long life. Years later, Ashly remains committed to these principles.
Ashly’s exclusive five-year, worry-free warranty remains one of the most generous policies available on any commercial- grade product. The warranty covers every product with the Ashly brand name, and is offered at no extra cost to you.
Please read this entire manual to fully understand the features and capabilities of this product.
■ Reorient or relocate the receiving
antenna.
■ Increase the separation between the
equipment and receiver.
■ Connect the equipment into an outlet on
a circuit different from that to which the receiver is connected.
■ Consult the dealer or an experienced
radio/TV technician for help.
3
CA Amplifier • Operating Manual
Table of Contents
1 Introduction .................. 4
2 Requirements ................4
2.1 AC mains ....................... 4
2.2 Input wiring .................... 5
2.3 Speaker wire ...................5
2.4 Remote control wire ....... 5
2.5 Mechanical .................... 5
2.6 Cooling .......................... 6
3 Amplifier Protection ....... 6
4 Front Panel Features ......7
4.1 Air vents ......................... 7
4.2 Channel LED indicators .. 7
4.3 Protect LED .................... 7
4.4 Disable LED .................... 7
4.5 Channel attenuators ...... 7
4.6 Bridge LED ...................... 7
4.7 Power switch/LED .......... 7
4.8 Model number ................ 7
4.9 Mounting holes .............. 7
5 Rear Panel Features .......8
5.1 Standby connector ........ 8
5.2a Standby polarity ............ 8
5.2b Front panel disable ........ 8
5.3a DIP switch (HPF) .............8
5.3b DIP switch (limiter) ..........8
5.3c DIP switch (gain) .............8
5.4 Euroblock input jack ........8
5.5 Remote DC level control ..8
5.6 Bridge mode switch .........8
5.7 Combo input jacks ...........9
5.8 Speaker outputs ..............9
5.9 AC mains .........................9
6 Troubleshooting ............9
7 Specifications ....... 10-11
8 Warranty .................... 12
1 Introduction
Thank you for your purchase of this Ashly CA power amplifier. This product uses state of the art, light weight, high power, high efficiency switching technology developed through years of design and testing. CA amplifiers are available in three power levels, designed to meet the most demanding live sound and fixed installation sound systems in stadiums, arenas, performance venues, worship spaces and convention centers.
1.2 Features
Two or four channel models
500W, 1,000W, or 1,500W per channel
models
Active power factor correction (PFC)
Low impedance output (to 2 Ohm)
Direct 70V or 100V output
Extremely efficient and lightweight
Neutrik® Combo XLR - 1/4" jack and
Euroblock input connectors
Euroblock speaker output connectors
Front panel soft-power switch, defeatable
Front panel level controls, fully off = mute,
defeatable
Front panel LEDs for clip/mute, signal,
current, temperature, bridge mode, protect, and front panel disable
80Hz 2nd order hi-pass filter per channel
(on/off)
Clip limiter per channel (on/off)
Input gain settings per channel: 26dB,
32dB, 38dB, or 1.4V
Remote DC level control per channel
Remote standby contact closure, with
polarity setting
Universal 100-240VAC operation, 50-60Hz,
detachable AC connector
Continuously variable cooling fan(s)
Protection: Inrush current limitation, over-
temperature, output short-circuit/over­power, output DC, mains fuse
Safety/Compliance: cTUVus, CE, FCC Class
B, RoHS
Ashly five year warranty
2 Requirements
Before connecting to AC mains power, make sure that the mechanical installation, cooling requirements, wiring, and controls are all set to the configuration needed for your application. Failure to do so could result in damage to the unit or to other components in the system.
2.1 AC Mains
This amplifier will auto-detect AC mains voltage from 100 to 240VAC, 50-60Hz. For nominal 120VAC mains, the allowed operating range is 70-135VAC, with 85VAC required for start-up. For nominal 240VAC operation the range is 140-270VAC. Use only the provided AC cord to connect to AC mains.
All CA models have a fixed, non-defeatable warm-up delay of two seconds to protect against excessive in-rush current when first
4
Loading...
+ 8 hidden pages