TABLES REFRIGERATORS AND FREEZERS
Manual for installation, use, and maintenance
TABLES SERVICE MANUAL / Rev. JUN. 2015
Contents
1 |
RECEIVING AND INSPECTING THE EQUIPMENT.................................................................................... |
3 |
|
2 |
SPECIFICATIONS .................................................................................................................................... |
4 |
|
3 |
DIMENSIONS ......................................................................................................................................... |
6 |
|
4 |
INSTALLATION..................................................................................................................................... |
10 |
|
|
4.1 |
UNCRATING.................................................................................................................................... |
10 |
|
4.2 |
LOCATION ...................................................................................................................................... |
10 |
|
4.3 |
DATA PLATE.................................................................................................................................... |
11 |
|
4.4 |
INSTALLATION OF CASTORS OR OPTIONAL LEGS........................................................................... |
11 |
|
4.5 |
LEVELING........................................................................................................................................ |
12 |
|
4.6 |
ELECTRICAL CONNECTIONS............................................................................................................ |
12 |
|
4.7 |
SHELVING INSTALLATION............................................................................................................... |
13 |
5 |
OPERATION ......................................................................................................................................... |
13 |
|
|
5.1 |
ANALOG THERMOSTAT.................................................................................................................. |
14 |
|
5.2 |
ELECTRONIC CONTROL................................................................................................................... |
15 |
|
5.3 |
OTHER FUNCTIONS ........................................................................................................................ |
17 |
6 |
MAINTENANCE.................................................................................................................................... |
18 |
|
|
6.1 |
GASKET........................................................................................................................................... |
19 |
|
6.2 |
DOORS/HINGES.............................................................................................................................. |
19 |
|
6.3 |
DRAIN............................................................................................................................................. |
19 |
7 |
TROUBLE SHOOTING........................................................................................................................... |
21 |
|
8 |
WIRING DIAGRAMS............................................................................................................................. |
22 |
|
Limited Warranty...................................................................................................................................... |
27 |
Page2
TABLES SERVICE MANUAL / Rev. JUN. 2015
1 RECEIVING AND INSPECTING THE EQUIPMENT
Up on receiving your new Asber Refrigerator, check the package and the machine for any damages that may have occurred during transportation. Visually inspect the exterior of the package. I f damaged, open and inspect the contents with the carrier. Any damage should be noted and reported on the delivering carrier’s receipt.
In the event that the exterior is not damaged, yet up on opening, there is concealed damage to the equipment notify, the carrier immediately. Notification should be made verbally as well as in written form. Request an inspection by the shipping company of the damaged equipment. Retain all crating material until inspection has been made. Contact the dealer through which you purchased the unit.
Check the compressor compartment housing and visually inspect the refrigeration package. Be sure lines are secure and base is still intact.
A NOTE FROM OUR QUALITY CONTROL MANAGER
CONGRATULATIONS ON YOUR NEW PURCHASE. WE WOULD LIKE TO WELCOME YOU TO THE ASBER TEAM. THE UNIT IN FRONT OF YOU IS A GREAT PIECE OF EQUIPMENT THAT WILL BECOME ONE OF YOUR MOST RELAIBLE TOOLS IN YOUR DAILY OPERATIONS FOR YEARS TO COME!
PRIOR TO SHIPPING YOUR UNIT, OUR TRAINED SERVICE TECHNICIANS TESTED YOUR UNIT FOR A PERIOD OF 12 HOURS. THIS PERFORMANCE TEST WAS RECORDED AND A COPY OF THE RESULTS IS INCLUDED WITH THIS SERVICE MANUAL. DURING THIS TEST, OUR HIGHLY QUALIFIED PERSONNEL INSPECTED YOUR MACHINE FOR LEAKS, LOSE COMPONENTS, AND IMPROPER NOISE LEVELS. WE ALSO TESTED THE COOLING PERFORMANCE IN AN EFFORT TO GIVE YOU THE BEST AND MOST RELAIBLE UNIT POSSIBLE.
Page3
TABLES SERVICE MANUAL / Rev. JUN. 2015
2 |
SPECIFICATIONS |
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Capac. |
Top |
#of |
|
BTU'S/ |
Temperature Operation |
Pressure in |
Super- |
|
Ref. |
Ship |
|
Model |
|
|
|
Ref. amt. |
||||||||
(Cu.Ft.) |
Pans |
Shvls |
|
Hr |
Set Point |
Cut in |
Suction Line* |
Heat** |
Type |
Weight |
||
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
AUTR-27 |
6.1 |
- |
2 |
|
1449 |
5°C/41°F |
4°C A 6°C |
10-16PSIG |
7°C/13°F |
8.5oz |
R-134a |
204 |
|
(37°F A 43 °F) |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
AUTR-48 |
11.8 |
- |
4 |
|
1666 |
5°C/41°F |
-4°C A 1°C |
10-16PSIG |
7°C/13°F |
9.9oz |
R-134a |
289 |
|
(25°F A 36°F) |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
AUTR-60 |
15 |
- |
4 |
|
2104 |
5°C/41°F |
-4°C A 1°C |
10-16PSIG |
7°C/13°F |
10.6oz |
R-134a |
343 |
|
(25°F A 36°F) |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
AUTR-72 |
18.2 |
- |
6 |
|
2104 |
5°C/41°F |
-4°C A 1°C |
10-16PSIG |
7°C/13°F |
10.6oz |
R-134a |
413 |
|
(25°F A 36°F) |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
AUTF-27 |
6.1 |
- |
2 |
|
2493 |
-20°C/-4°F |
-22°C A -20°C |
14-16PSIG |
4°C/7°F |
9.5 oz |
R-404A |
204 |
|
(-8°F A-4°F) |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
AUTF-48 |
11.8 |
- |
4 |
|
2493 |
-20°C/-8°F |
-17°C A -16°C |
14-16PSIG |
4°C/7°F |
19.4oz |
R-404A |
289 |
|
(2°F A 4 °F) |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
AUTF-60 |
15 |
- |
4 |
|
2493 |
-20°C/-8°F |
-17°C A -16°C |
14-16PSIG |
4°C/7°F |
19.4oz |
R-404A |
343 |
|
(2°F A 4 °F) |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
APTS-27-8 |
- |
8 |
1 |
|
1449 |
5°C/41°F |
-4°C A 1°C |
10-16PSIG |
7°C/13°F |
8.5oz |
R-134a |
214 |
|
(25°F A 36°F) |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
APTS-48-12 |
- |
12 |
2 |
|
1666 |
5°C/41°F |
-4°C A 1°C |
10-16PSIG |
7°C/13°F |
9.8oz |
R-134a |
305 |
|
(25°F A 36°F) |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
APTS-60-16 |
- |
16 |
2 |
|
2104 |
-2°C/28°F |
5°C/41°F |
10-16PSIG |
7°C/13°F |
10.6oz |
R-134a |
370 |
|
|
|
|
|
|
|
|
|
|
|
|
|
APTS-72-18 |
- |
18 |
3 |
|
2104 |
-2°C/28°F |
5°C/41°F |
10-16PSIG |
7°C/13°F |
10.6oz |
R-134a |
455 |
|
|
|
|
|
|
|
|
|
|
|
|
|
APTM-27-12 |
- |
12 |
1 |
|
1449 |
-2°C/28°F |
5°C/41°F |
10-16PSIG |
7°C/13°F |
8.5oz |
R-134a |
255 |
|
|
|
|
|
|
|
|
|
|
|
|
|
APTM-48-18 |
- |
18 |
2 |
|
1666 |
-2°C/28°F |
5°C/41°F |
10-16PSIG |
7°C/13°F |
9.8oz |
R-134a |
327 |
|
|
|
|
|
|
|
|
|
|
|
|
|
APTM-60-24 |
- |
24 |
2 |
|
2104 |
-2°C/28°F |
5°C/41°F |
10-16PSIG |
7°C/13°F |
10.6oz |
R-134a |
380 |
|
|
|
|
|
|
|
|
|
|
|
|
|
APTM-72-30 |
- |
30 |
3 |
|
2104 |
-2°C/28°F |
5°C/41°F |
10-16PSIG |
7°C/13°F |
10.6oz |
R-134a |
465 |
APTP-46 |
13.9 |
6 |
2 |
|
1666 |
5°C/41°F |
-4°C A 1°C |
10-16PSIG |
7°C/13°F |
10.6oz |
R-134a |
318 |
|
(25°F A 36°F) |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
APTP -67 |
23.6 |
9 |
4 |
|
2104 |
5°C/41°F |
-4°C A 1°C |
10-16PSIG |
7°C/13°F |
10.6oz |
R-134a |
490 |
|
(25°F A 36°F) |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
ACBR-53 |
18.6 |
9 |
4 |
|
2104 |
-2°C/28°F |
5°C/41°F |
12 PSIG |
7°C/13°F |
10.2oz |
R-134a |
490 |
ACBR-73 |
6.1 |
- |
2 |
|
2493 |
-2°C/28°F |
5°C/41°F |
12 PSIG |
7°C/13°F |
10.2oz |
R-134a |
204 |
|
|
|
|
|
|
|
|
|
|
|
|
|
ACBR-88 |
15 |
- |
4 |
|
2104 |
-2°C/28°F |
5°C/41°F |
12 PSIG |
7°C/13°F |
10.2oz |
R-134a |
343 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Note:
* The pressure in the suction line is recommended at 32°C / 90°F maximum of ambient temperature.
**Superheat measured in the outlet of the evaporator at 32°C / 90°F
Page4
TABLES SERVICE MANUAL / Rev. JUN. 2015
UNDERCOUNTERS, WORKTOPS AND FOOD PREP TABLES REFRIGERATORS AND FREEZERS, ELECTRICAL SPECS
|
|
|
Amp. |
NEMA |
Breaker |
Wire gauge recommended for 2% voltage drop in supply circuits ** |
||||||
Models |
HP1 |
Voltage |
Max. |
PLUG. |
Size.* |
40 ft *** |
60 ft |
80 ft |
100 ft |
120 ft |
140 ft |
|
AUTR-27 |
1/6 |
115 |
2.7 |
5-15P |
10 amp |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
12 AWG |
|
1/4 |
220 |
2.1 |
2P+TT |
10 amp |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
||
|
||||||||||||
AUTR-48 |
1/4 |
115 |
5.4 |
5-15P |
10 amp |
14 AWG |
14 AWG |
14 AWG |
12 AWG |
12 AWG |
10 AWG |
|
220 |
2.8 |
2P+TT |
10 amp |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
12 AWG |
|||
|
|
|||||||||||
AUTR-60 |
1/3 |
115 |
6.7 |
5-15P |
10 amp |
14 AWG |
14 AWG |
12 AWG |
12 AWG |
10AWG |
10 AWG |
|
3/8 |
220 |
3.5 |
2P+TT |
10 amp |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
||
|
||||||||||||
AUTR-72 |
1/3 |
115 |
6.2 |
5-15P |
10 amp |
14 AWG |
14 AWG |
12 AWG |
12 AWG |
10AWG |
10 AWG |
|
3/8 |
220 |
3.2 |
2P+TT |
10 amp |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
||
|
||||||||||||
AUTF-27 |
3/4 |
115 |
8.2 |
5-15P |
15 amp |
14 AWG |
12 AWG |
12 AWG |
10 AWG |
10AWG |
8 AWG |
|
220 |
4.2 |
2P+TT |
10 amp |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
12 AWG |
|||
|
|
|||||||||||
AUTF-48 |
3/4 |
115 |
8.5 |
5-15P |
15 amp |
14 AWG |
12 AWG |
12 AWG |
10 AWG |
10AWG |
8 AWG |
|
220 |
4.2 |
2P+TT |
10 amp |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
12 AWG |
|||
|
|
|||||||||||
AUTF-60 |
3/4 |
115 |
8.5 |
5-15P |
15 amp |
14 AWG |
12 AWG |
12 AWG |
10 AWG |
10AWG |
8 AWG |
|
|
|
220 |
4.2 |
2P+TT |
10 amp |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
12 AWG |
|
APTS-27-8 |
1/6 |
115 |
2.7 |
5-15P |
10 amp |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
12 AWG |
|
1/4 |
220 |
2.1 |
2P+TT |
10 amp |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
||
|
||||||||||||
APTS-48-12 |
1/4 |
115 |
5.4 |
5-15P |
10 amp |
14 AWG |
14 AWG |
14 AWG |
12 AWG |
12 AWG |
10 AWG |
|
220 |
2.8 |
2P+TT |
10 amp |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
12 AWG |
|||
|
|
|||||||||||
APTS-60-16 |
1/3 |
115 |
6.7 |
5-15P |
10 amp |
14 AWG |
14 AWG |
12 AWG |
12 AWG |
10AWG |
10 AWG |
|
3/8 |
220 |
3.5 |
2P+TT |
10 amp |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
||
|
||||||||||||
APST-72-18 |
1/3 |
115 |
6.2 |
5-15P |
10 amp |
14 AWG |
14 AWG |
12 AWG |
12 AWG |
10AWG |
10 AWG |
|
3/8 |
220 |
3.2 |
2P+TT |
10 amp |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
||
|
||||||||||||
APTM-27-12 |
1/6 |
115 |
2.7 |
5-15P |
10 amp |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
12 AWG |
|
1/4 |
220 |
2.1 |
2P+TT |
10 amp |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
||
|
||||||||||||
APTM-48-18 |
1/4 |
115 |
5.4 |
5-15P |
10 amp |
14 AWG |
14 AWG |
14 AWG |
12 AWG |
12 AWG |
10 AWG |
|
220 |
2.8 |
2P+TT |
10 amp |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
12 AWG |
|||
|
|
|||||||||||
APTM-60-24 |
1/3 |
115 |
6.7 |
5-15P |
10 amp |
14 AWG |
14 AWG |
12 AWG |
12 AWG |
10AWG |
10 AWG |
|
3/8 |
220 |
3.5 |
2P+TT |
10 amp |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
||
|
||||||||||||
APTM-72-30 |
1/3 |
115 |
6.2 |
5-15P |
10 amp |
14 AWG |
14 AWG |
12 AWG |
12 AWG |
10AWG |
10 AWG |
|
3/8 |
|
|
|
|
|
|
|
|
|
|
||
|
220 |
3.2 |
2P+TT |
10 amp |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
||
|
|
|||||||||||
APTP-46 |
1/4 |
115 |
5.4 |
5-15P |
10 amp |
14 AWG |
14 AWG |
14 AWG |
12 AWG |
12 AWG |
10 AWG |
|
220 |
2.8 |
2P+TT |
10 amp |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
12 AWG |
|||
|
|
|||||||||||
APTP-67 |
1/3 |
115 |
6.7 |
5-15P |
10 amp |
14 AWG |
14 AWG |
12 AWG |
12 AWG |
10AWG |
10 AWG |
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
220 |
3.5 |
2P+TT |
10 amp |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
14 AWG |
|
ACBR-53 |
1/6 |
115 |
2.3 |
5-15P |
10 amp |
14 AWG |
14 AWG |
12 AWG |
12 AWG |
10AWG |
10 AWG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ACBR73 |
1/4 |
115 |
5.5 |
5-15P |
10 amp |
14 AWG |
14 AWG |
12 AWG |
12 AWG |
10AWG |
10 AWG |
|
ACBR-88 |
1/4 |
115 |
5.5 |
5-15P |
10 amp |
14 AWG |
14 AWG |
12 AWG |
12 AWG |
10AWG |
10 AWG |
|
|
|
|
|
|
|
|
|
|
|
|
|
Note:
*Breaker sizes are recommended by the manufacturer to protect the equipment by overload; this breaker only must be dedicated for the equipment.
** If the equipment is installed faraway of the circuit breaker, these are the wire gauge recommend to connect the appliance; if the distance is higher that the chart values, please contact an electrician.
***Distance in feet from the breaker or the power supply to the appliance.
Page5
TABLES SERVICE MANUAL / Rev. JUN. 2015
3 DIMENSIONS
APTS 27
APTS 48
Page6
TABLES SERVICE MANUAL / Rev. JUN. 2015
APTS 60
APTS 72
Page7
TABLES SERVICE MANUAL / Rev. JUN. 2015
APTM 27
APTM 48
Page8
TABLES SERVICE MANUAL / Rev. JUN. 2015
APTM 60
APTM 72
Page9