Asber AUTR-27 Installation Manual

0 (0)

TABLES REFRIGERATORS AND FREEZERS

Manual for installation, use, and maintenance

TABLES SERVICE MANUAL / Rev. JUN. 2015

Contents

1

RECEIVING AND INSPECTING THE EQUIPMENT....................................................................................

3

2

SPECIFICATIONS ....................................................................................................................................

4

3

DIMENSIONS .........................................................................................................................................

6

4

INSTALLATION.....................................................................................................................................

10

 

4.1

UNCRATING....................................................................................................................................

10

 

4.2

LOCATION ......................................................................................................................................

10

 

4.3

DATA PLATE....................................................................................................................................

11

 

4.4

INSTALLATION OF CASTORS OR OPTIONAL LEGS...........................................................................

11

 

4.5

LEVELING........................................................................................................................................

12

 

4.6

ELECTRICAL CONNECTIONS............................................................................................................

12

 

4.7

SHELVING INSTALLATION...............................................................................................................

13

5

OPERATION .........................................................................................................................................

13

 

5.1

ANALOG THERMOSTAT..................................................................................................................

14

 

5.2

ELECTRONIC CONTROL...................................................................................................................

15

 

5.3

OTHER FUNCTIONS ........................................................................................................................

17

6

MAINTENANCE....................................................................................................................................

18

 

6.1

GASKET...........................................................................................................................................

19

 

6.2

DOORS/HINGES..............................................................................................................................

19

 

6.3

DRAIN.............................................................................................................................................

19

7

TROUBLE SHOOTING...........................................................................................................................

21

8

WIRING DIAGRAMS.............................................................................................................................

22

Limited Warranty......................................................................................................................................

27

Page2

TABLES SERVICE MANUAL / Rev. JUN. 2015

1 RECEIVING AND INSPECTING THE EQUIPMENT

Up on receiving your new Asber Refrigerator, check the package and the machine for any damages that may have occurred during transportation. Visually inspect the exterior of the package. I f damaged, open and inspect the contents with the carrier. Any damage should be noted and reported on the delivering carrier’s receipt.

In the event that the exterior is not damaged, yet up on opening, there is concealed damage to the equipment notify, the carrier immediately. Notification should be made verbally as well as in written form. Request an inspection by the shipping company of the damaged equipment. Retain all crating material until inspection has been made. Contact the dealer through which you purchased the unit.

Check the compressor compartment housing and visually inspect the refrigeration package. Be sure lines are secure and base is still intact.

A NOTE FROM OUR QUALITY CONTROL MANAGER

CONGRATULATIONS ON YOUR NEW PURCHASE. WE WOULD LIKE TO WELCOME YOU TO THE ASBER TEAM. THE UNIT IN FRONT OF YOU IS A GREAT PIECE OF EQUIPMENT THAT WILL BECOME ONE OF YOUR MOST RELAIBLE TOOLS IN YOUR DAILY OPERATIONS FOR YEARS TO COME!

PRIOR TO SHIPPING YOUR UNIT, OUR TRAINED SERVICE TECHNICIANS TESTED YOUR UNIT FOR A PERIOD OF 12 HOURS. THIS PERFORMANCE TEST WAS RECORDED AND A COPY OF THE RESULTS IS INCLUDED WITH THIS SERVICE MANUAL. DURING THIS TEST, OUR HIGHLY QUALIFIED PERSONNEL INSPECTED YOUR MACHINE FOR LEAKS, LOSE COMPONENTS, AND IMPROPER NOISE LEVELS. WE ALSO TESTED THE COOLING PERFORMANCE IN AN EFFORT TO GIVE YOU THE BEST AND MOST RELAIBLE UNIT POSSIBLE.

Page3

TABLES SERVICE MANUAL / Rev. JUN. 2015

2

SPECIFICATIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capac.

Top

#of

 

BTU'S/

Temperature Operation

Pressure in

Super-

 

Ref.

Ship

Model

 

 

 

Ref. amt.

(Cu.Ft.)

Pans

Shvls

 

Hr

Set Point

Cut in

Suction Line*

Heat**

Type

Weight

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUTR-27

6.1

-

2

 

1449

5°C/41°F

4°C A 6°C

10-16PSIG

7°C/13°F

8.5oz

R-134a

204

 

(37°F A 43 °F)

 

 

 

 

 

 

 

 

 

 

 

 

AUTR-48

11.8

-

4

 

1666

5°C/41°F

-4°C A 1°C

10-16PSIG

7°C/13°F

9.9oz

R-134a

289

 

(25°F A 36°F)

 

 

 

 

 

 

 

 

 

 

 

 

AUTR-60

15

-

4

 

2104

5°C/41°F

-4°C A 1°C

10-16PSIG

7°C/13°F

10.6oz

R-134a

343

 

(25°F A 36°F)

 

 

 

 

 

 

 

 

 

 

 

 

AUTR-72

18.2

-

6

 

2104

5°C/41°F

-4°C A 1°C

10-16PSIG

7°C/13°F

10.6oz

R-134a

413

 

(25°F A 36°F)

 

 

 

 

 

 

 

 

 

 

 

 

AUTF-27

6.1

-

2

 

2493

-20°C/-4°F

-22°C A -20°C

14-16PSIG

4°C/7°F

9.5 oz

R-404A

204

 

(-8°F A-4°F)

 

 

 

 

 

 

 

 

 

 

 

 

AUTF-48

11.8

-

4

 

2493

-20°C/-8°F

-17°C A -16°C

14-16PSIG

4°C/7°F

19.4oz

R-404A

289

 

(2°F A 4 °F)

 

 

 

 

 

 

 

 

 

 

 

 

AUTF-60

15

-

4

 

2493

-20°C/-8°F

-17°C A -16°C

14-16PSIG

4°C/7°F

19.4oz

R-404A

343

 

(2°F A 4 °F)

 

 

 

 

 

 

 

 

 

 

 

 

APTS-27-8

-

8

1

 

1449

5°C/41°F

-4°C A 1°C

10-16PSIG

7°C/13°F

8.5oz

R-134a

214

 

(25°F A 36°F)

 

 

 

 

 

 

 

 

 

 

 

 

APTS-48-12

-

12

2

 

1666

5°C/41°F

-4°C A 1°C

10-16PSIG

7°C/13°F

9.8oz

R-134a

305

 

(25°F A 36°F)

 

 

 

 

 

 

 

 

 

 

 

 

APTS-60-16

-

16

2

 

2104

-2°C/28°F

5°C/41°F

10-16PSIG

7°C/13°F

10.6oz

R-134a

370

 

 

 

 

 

 

 

 

 

 

 

 

 

APTS-72-18

-

18

3

 

2104

-2°C/28°F

5°C/41°F

10-16PSIG

7°C/13°F

10.6oz

R-134a

455

 

 

 

 

 

 

 

 

 

 

 

 

 

APTM-27-12

-

12

1

 

1449

-2°C/28°F

5°C/41°F

10-16PSIG

7°C/13°F

8.5oz

R-134a

255

 

 

 

 

 

 

 

 

 

 

 

 

 

APTM-48-18

-

18

2

 

1666

-2°C/28°F

5°C/41°F

10-16PSIG

7°C/13°F

9.8oz

R-134a

327

 

 

 

 

 

 

 

 

 

 

 

 

 

APTM-60-24

-

24

2

 

2104

-2°C/28°F

5°C/41°F

10-16PSIG

7°C/13°F

10.6oz

R-134a

380

 

 

 

 

 

 

 

 

 

 

 

 

 

APTM-72-30

-

30

3

 

2104

-2°C/28°F

5°C/41°F

10-16PSIG

7°C/13°F

10.6oz

R-134a

465

APTP-46

13.9

6

2

 

1666

5°C/41°F

-4°C A 1°C

10-16PSIG

7°C/13°F

10.6oz

R-134a

318

 

(25°F A 36°F)

 

 

 

 

 

 

 

 

 

 

 

 

APTP -67

23.6

9

4

 

2104

5°C/41°F

-4°C A 1°C

10-16PSIG

7°C/13°F

10.6oz

R-134a

490

 

(25°F A 36°F)

 

 

 

 

 

 

 

 

 

 

 

 

ACBR-53

18.6

9

4

 

2104

-2°C/28°F

5°C/41°F

12 PSIG

7°C/13°F

10.2oz

R-134a

490

ACBR-73

6.1

-

2

 

2493

-2°C/28°F

5°C/41°F

12 PSIG

7°C/13°F

10.2oz

R-134a

204

 

 

 

 

 

 

 

 

 

 

 

 

 

ACBR-88

15

-

4

 

2104

-2°C/28°F

5°C/41°F

12 PSIG

7°C/13°F

10.2oz

R-134a

343

 

 

 

 

 

 

 

 

 

 

 

 

 

Note:

* The pressure in the suction line is recommended at 32°C / 90°F maximum of ambient temperature.

**Superheat measured in the outlet of the evaporator at 32°C / 90°F

Page4

TABLES SERVICE MANUAL / Rev. JUN. 2015

UNDERCOUNTERS, WORKTOPS AND FOOD PREP TABLES REFRIGERATORS AND FREEZERS, ELECTRICAL SPECS

 

 

 

Amp.

NEMA

Breaker

Wire gauge recommended for 2% voltage drop in supply circuits **

Models

HP1

Voltage

Max.

PLUG.

Size.*

40 ft ***

60 ft

80 ft

100 ft

120 ft

140 ft

AUTR-27

1/6

115

2.7

5-15P

10 amp

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

12 AWG

1/4

220

2.1

2P+TT

10 amp

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

 

AUTR-48

1/4

115

5.4

5-15P

10 amp

14 AWG

14 AWG

14 AWG

12 AWG

12 AWG

10 AWG

220

2.8

2P+TT

10 amp

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

12 AWG

 

 

AUTR-60

1/3

115

6.7

5-15P

10 amp

14 AWG

14 AWG

12 AWG

12 AWG

10AWG

10 AWG

3/8

220

3.5

2P+TT

10 amp

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

 

AUTR-72

1/3

115

6.2

5-15P

10 amp

14 AWG

14 AWG

12 AWG

12 AWG

10AWG

10 AWG

3/8

220

3.2

2P+TT

10 amp

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

 

AUTF-27

3/4

115

8.2

5-15P

15 amp

14 AWG

12 AWG

12 AWG

10 AWG

10AWG

8 AWG

220

4.2

2P+TT

10 amp

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

12 AWG

 

 

AUTF-48

3/4

115

8.5

5-15P

15 amp

14 AWG

12 AWG

12 AWG

10 AWG

10AWG

8 AWG

220

4.2

2P+TT

10 amp

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

12 AWG

 

 

AUTF-60

3/4

115

8.5

5-15P

15 amp

14 AWG

12 AWG

12 AWG

10 AWG

10AWG

8 AWG

 

 

220

4.2

2P+TT

10 amp

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

12 AWG

APTS-27-8

1/6

115

2.7

5-15P

10 amp

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

12 AWG

1/4

220

2.1

2P+TT

10 amp

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

 

APTS-48-12

1/4

115

5.4

5-15P

10 amp

14 AWG

14 AWG

14 AWG

12 AWG

12 AWG

10 AWG

220

2.8

2P+TT

10 amp

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

12 AWG

 

 

APTS-60-16

1/3

115

6.7

5-15P

10 amp

14 AWG

14 AWG

12 AWG

12 AWG

10AWG

10 AWG

3/8

220

3.5

2P+TT

10 amp

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

 

APST-72-18

1/3

115

6.2

5-15P

10 amp

14 AWG

14 AWG

12 AWG

12 AWG

10AWG

10 AWG

3/8

220

3.2

2P+TT

10 amp

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

 

APTM-27-12

1/6

115

2.7

5-15P

10 amp

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

12 AWG

1/4

220

2.1

2P+TT

10 amp

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

 

APTM-48-18

1/4

115

5.4

5-15P

10 amp

14 AWG

14 AWG

14 AWG

12 AWG

12 AWG

10 AWG

220

2.8

2P+TT

10 amp

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

12 AWG

 

 

APTM-60-24

1/3

115

6.7

5-15P

10 amp

14 AWG

14 AWG

12 AWG

12 AWG

10AWG

10 AWG

3/8

220

3.5

2P+TT

10 amp

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

 

APTM-72-30

1/3

115

6.2

5-15P

10 amp

14 AWG

14 AWG

12 AWG

12 AWG

10AWG

10 AWG

3/8

 

 

 

 

 

 

 

 

 

 

 

220

3.2

2P+TT

10 amp

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

 

 

APTP-46

1/4

115

5.4

5-15P

10 amp

14 AWG

14 AWG

14 AWG

12 AWG

12 AWG

10 AWG

220

2.8

2P+TT

10 amp

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

12 AWG

 

 

APTP-67

1/3

115

6.7

5-15P

10 amp

14 AWG

14 AWG

12 AWG

12 AWG

10AWG

10 AWG

 

 

 

 

 

 

 

 

 

 

 

 

220

3.5

2P+TT

10 amp

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

ACBR-53

1/6

115

2.3

5-15P

10 amp

14 AWG

14 AWG

12 AWG

12 AWG

10AWG

10 AWG

 

 

 

 

 

 

 

 

 

 

 

 

ACBR73

1/4

115

5.5

5-15P

10 amp

14 AWG

14 AWG

12 AWG

12 AWG

10AWG

10 AWG

ACBR-88

1/4

115

5.5

5-15P

10 amp

14 AWG

14 AWG

12 AWG

12 AWG

10AWG

10 AWG

 

 

 

 

 

 

 

 

 

 

 

 

Note:

*Breaker sizes are recommended by the manufacturer to protect the equipment by overload; this breaker only must be dedicated for the equipment.

** If the equipment is installed faraway of the circuit breaker, these are the wire gauge recommend to connect the appliance; if the distance is higher that the chart values, please contact an electrician.

***Distance in feet from the breaker or the power supply to the appliance.

Page5

TABLES SERVICE MANUAL / Rev. JUN. 2015

3 DIMENSIONS

APTS 27

APTS 48

Page6

Asber AUTR-27 Installation Manual

TABLES SERVICE MANUAL / Rev. JUN. 2015

APTS 60

APTS 72

Page7

TABLES SERVICE MANUAL / Rev. JUN. 2015

APTM 27

APTM 48

Page8

TABLES SERVICE MANUAL / Rev. JUN. 2015

APTM 60

APTM 72

Page9

Loading...
+ 19 hidden pages