Arri ARRIFLEX 435 Quick Start Guide

435 Quick Guide
9/97
Customer Support/Safety Specifications ...........................2
Camera Left & Front........................................................3
Camera Right & Back .....................................................4
1. Quick Specs.................................................5
2. Status Indicators..........................................6
3. Loading the ARRIMAG 120 (400’)................7
4. Threading ...................................................9
5. Power On, Camera RUN, Inching...............11
6. Changing Fps ............................................12
7. Changing Shutter Angle.............................13
8. Timecode Sensitivity Table .........................15
Customer Support/Safety Specifications
Customer Support
If you have a question or problem, please contact one of our offices at the following addresses. In the case of inquiries or when ordering parts, please refer to the camera model and serial number.
Arriflex Corporation, East Coast
617 Route 303, Blauvelt, NY 10913-1109 Voice phone: 914-353-1400 FAX: 914-425-1250 Email: Arriflex@arri.com Website: http://www.arri.com
Arriflex Corporation, West Coast
600 North Victory Blvd., Burbank, CA 91502-1639 Voice phone: 818-841-7070 FAX: 818-848-4028
435 and 435ES
The ARRIFLEX 435 is available in two different models: the 435ES is equipped with an electronic shutter and a FEM (Functional Expansion Module). The standard 435 has a manually adjustable shutter and no FEM. Please note that the FEM is needed for the new 24 V accessories (including the CCU, RCU and ESU), for the LCC (Laptop Camera Controller) and for Timecode use.
About This Quick Guide
If you are viewing the Adobe Acrobat version of this Quick Guide, best viewing and printing results can be achieved through the use of the Acrobat Reader version 3.0 or later. The Acrobat Reader can be downloaded for free from the Adobe web site at http://www.adobe.com.
Safety Specifications
• The RS, ACC and CCU receptacles output the same voltage as is supplied to the BAT receptacle. If the BAT receptacle input voltage is above 32 V, the voltage output of the RS, ACC and CCU receptacles will be limited to 32 V/2 amp. Ensure that all accessories are suited to the supplied voltage.
• When transporting the camera, make sure that the sliding door securing the field lens is all the way down.
• When using the RCU, always reset the shutter angle to the desired value before disconnecting the RCU.
• In order to ensure optimal performance, it is essential that you acquaint yourself with this Quick Guide and that you follow the operating instructions described herein. We strongly recommend that you also acquaint yourself with the full 435 instruction manual.
• Assembly and initial operation should only be carried out after carefully reading the instructions and familiarizing yourself with the equipment and the assembly procedures.
• Repairs should be carried out only by authorized service centers. Use only original ARRI accessories and replacement parts.
• Never run the camera without a lens or a protective cap in the lens mount receptacle.
• Never place your hand in the lens cavity or the inside of the camera while the camera is running!
• Never open the movement or gate locking mechanism while the camera is running!
• When manually adjusting the mirror shutter, turn the camera off and remove the power cable. Accidentally running the camera while manually adjusting the mirror shutter can cause great damage.
• Clean optical surfaces only with an optical brush or a clean optical cloth. In cases of solid dirt, moisten an optical cloth with pure alcohol or a brand-name lens cleaner.
• Do not use solvents when cleaning the film path.
• Do not remove any screws which are secured with paint.

Camera Left & Front

Eyepiece focus adjustment
Eyecup
Eyepiece lock
Arriglow brightness adjustment
Camera door lock
Run indicator light
MODE button
SEL button
SET button
Image rotation knob
Image rotation release
Sliding door securing field lens
Friction adjustment
Viewfinder
Viewfinder extension lock
Ground glass
PL mount
LCD display
PROG button
Locking slider
Run button
Electronic inching/PHASE button
400 foot magazine
Magazine door lock
Door lock safety button
NORM - PS/CCU switch

Camera Right & Back

Video assist port
Grip system
Magazine opening cover
Viewfinder swivel release Tape hookContrast filter lever
Bubble level
Grip system
Two 3/8-16 mounting holes underneath camera
RS receptacle
(remote RUN & 24 V dc)
24 V accessory overload light
Tensioning plate
Tensioning plate
Mechanical footage counter
BAT receptacle (power input)
Main power on/off switch
12 V accessory
overload light
11 pin (12 V) accessory
receptacle
CCU receptacle
(camera control unit)
ACC receptacle
(accessories)
Compartment for 9 V timecode battery
Functional expansion module (FEM)
Functional expansion
module (FEM)
Magazine release latch

1. Quick Specs

Arriflex 435 Quick Guide, 9/97, Page 5
Fps range: ARRIMAG magazines: 1.000 to 150.00 fps, forward and reverse
35-3/2C magazines: 1.000 to 130.00 fps forward; reverse only with 35-3/2C 400’ (120m) magazines. 35-3 shoulder magazines cannot be used.
Mirror shutter: 435ES: 11.2° to 180.0°, electronically adjustable in 0.1° increments
435: 11.2° to 180.0°, manually adjustable to: 11.2°, 22.5°, 30°,
45°, 60°, 75°, 90°, 105°, 120°, 135°, 144°, 172.8° and 180°
Power: BAT: Up to 130 fps: 24 V dc in, above 130 fps: > 24 V dc in
(Use 26 V (min. 7Ah) batteries to cover the whole fps range) Pin #1 is negative, pin #2 is positive
Acceptable voltage range: 20.6 to 35 V dc RS: Pin #1 is GND, pin #2 is +24V dc out, pin #3 is /E-Run ACC Pin #4 is GND, pin #3 is +24 V dc out CCU: Pin #4 is GND, pin #3 is +24 V dc out 11-Pin: Pin #9 is GND, pin #11 is +12.6 V dc out Power output: All 24 V dc outputs total: max. 3 amp continuous, 5 amp peak
All 12 V dc outputs total: max. 3 amp continuous, 5 amp peak Fuses: All 435 fuses are self-resetting thermal fuses. If blown, the
respective overload light will illuminate. To reset fuse, disconnect
all accessories and wait for one minute.
Movement: Two three-pin pull-down film transport claws and two registration pins Flange focal distance: 51.98 - 51.97 mm Temperature range: -4° Fahrenheit to +122° Fahrenheit (-20°Celsius to +50°Celsius) Contrast Filter: Selectable ND 0.6 Electronic Accessories: IVS Integrated Video System
CCD-2FR Video Assist system RCU-1 Remote Control Unit LCC 1.3 Laptop Camera Controller CCU-1 Camera Control Unit LCS Lens Control System ICU-1 Iris Control Unit (for speed/iris ramps) RS-4 Remote On/Off Switch ESU-1 External Synchronization Unit
Other Accessories: 400’ magazine (ARRIMAG 120), 400’ Steadicam magazine (ARRIMAG
120S), 1000’ magazine (ARRIMAG 300E), a wide variety of zoom and prime lenses, viewfinder extenders, anamorphic viewfinder, heated eyecup, exchangeable ground glasses and Arriglow masks, various matte box systems, various follow focus systems, right side on/off button, right side handgrip, hand held shoulder supports, Steadicam support bracket, lens light, accessory connector splitter boxes, timecode exposure module, batteries, power supply, geared head, Varicon contrast control, obie light