Arcam Delta 250 User Manual

ARCAM
DELTA 250 CD TRANSPORT
DELTA 270 CD PLAYER
HANDBOOK
TECHNICAL SPECIFICATIONS
Delta 270
Convetiion System
Dynamic range
Harmonic distortion (OdB)
Frequency response (i 0.2dB)
Output level (OdB)
Output impedance
Minimum recommended load
Supplied accessories
Delta 2501 270
Digtal outputs
Power consumption
Size W/D/H mm.
Wei^c
Hybrid 18 bit DAC Upper bit range multi-bit Lower bit rangé single-bit
lOSdB
103dB
0.005%
IHz - 20kHz
2.3V RMS
22ohm3
IKohm
remote control handset
(inc batteries)
mains lead
iEC 958 standard, SPDIF format
30VA
430x275x95
4.4kg nett.
5.6kg packed
Supplied accessories
E&OE.
AudioQuest video X digital cable Remote control handset
(inc batteries) mains lead
INSTALLATION
©
Check that your mains supply voltage agrees with the voltage setting indicated on the rear panel of the unit, if your mains supply voltage is different, consult your Arcam dealer.
MAINS SAFETY
This product is normally supplied \vith a moulded mains plug already fitted to the lead. If for any reason the plug needs to be removed, it must be disposed of immediately and securely, as it is a potential shock hazard when inserted into a mains socket. If the plug is removed then the remaining lead must be rewired as follows:
The blue wire must be connected to the terminal which is coloured blue or marked with the letter N. The brown wire must be connected to
the terminal which is coloured brown or marked with the letter L.
The green and yellow wire must be
connected to the temiinal which is coloured green and yellow, or marked with the letter E or the safety earth symbol.
When replacing the fuse in the supplied
moulded mains plug, the integral fuse
holder/cover must always be refitted.
Warning;
This apparatus must be
earthed.
• For optimum sonic performance, the analogue power supply of the CD player is kept powered up all the time the unit is connected to the mains supply. The firont panel power switch powers down all other circuitry leaving the analogue sections in "standby".
This means that even chough the power switch is off, it may be possible to hear a slight residual hum emanating from the mains transformer inside the CD player. This is perfecdy normal. Tithe unit is to be left unused for an extended period, we recommend that it is disconnected fi-om the maans supply by switching it off at the wall socket.
DELTA 270 ONLY DIGITAL AND AUDIO CONNECTIONS
DIGITAL OUTPUTS - For use with a separate digital to analogue converter
(DAC) or digital recorder. Connect to the unit’s digital input using a suitable digital cable. Both outputs are identical and can be connected simultaneously if necessary.
© AUDIO OUTPUT - Connect to your
amplifier's CD or AUX input using a
suitable interconnect cable. Insert the red phono plugs into the sockets labelled 'R,' and the other plugs into the sockets bbelled ’L'.
MAINS SUPPLY CONNECTIONS
Insert the EEC line socket of the mains lead fully into the power inlet socket on the rear panel. Connect the other end to your mains supply.
Loading...
+ 6 hidden pages