You have chosen not only one of the first cassette decks designed to use
the single chip Dolby S Noise Reduction (NR) system, but a cassette deck
that seriously livals CD for sound quality. Arcam is currently the only British
manufacturer with a cassette deck for the domestic market that is both
designed and built in the UK.
the rest of the Delta range, but any good quality system requiring a first rate
recording and replay capability. The inclusion of Dolby S type NR now gives
you superb sound quality with pre-recorded Dolby S type NR tapes, or wth
tapes recorded yourself that have been encoded with Dolby S type NR. The
Delta 100 is also fitted vnth Dolby B and C type NR, so ensuring complete
compatitMlity with ail your existing tapes. Dolby S type NR has also been
designed so that tapes encoded with Dolby S type NR will play on decks
fitted with Dolby B type NR. Any tape recorded at home on your Delta 100
can be played back on a personal stereo, portable deck. In the car, etc., and
give excellent results.
checked and tested to ensure trouble free performance. Please read these
Instructions fully before operating your Delta 100 and retain them for future
reference. This will ensure that you get the best results from your cassette
deck. Remember that your dealeris there to help youl He has extensive
knowle^e of all Arcam products and considerable experience of their use
in a variety of systems.
not hesitate to contact us directly at the factory.
following vo!tages;110V, 120V, 220V or 240V (100V units can be supplied
to special order). Please check that your local mains supply voltage agrees
with the voltage setting indicated on the back panel of the unit. If it does not.
please contact your dealeror distributor for details of how to proceed
further. A detachable mains lead Is supplied with the Delta 100.
Thank you tor buying the Arcam Delta 100 cassette deck.
The Delta 100 has been designed to complement not only
Each Arcam Delta 100 cassette deck has been thoroughly
If, however, he is unable to answer your query, please do
INSTALLING AND USING YOUR DELTA 100
Mains supply
The Delta 100 may be supplied to work on any of the
the following code:
plugs fitted as standard. If the colour-coded mains lead does not correspond
with the cobured markings identifying the terminals in your mains plug,
please proceed as follows:
connected to the terminal in the plug which is coloured green, or marked
with the safety earth symbol or the letter E'. The wire which is colour-coded
blue must be connected to the terminal cobured black or marked 'N'. The
wire which is colour-coded brown must be connected to the terminal
cobured red or marked 'L'.
inlet to the Delta 100 uses a standard lEC chassis mounting plug. The lEC
line socket on your mains lead, and the lEC plug on the Delta 100 are a
tight fit. Before using the unit, please ensure that the mains lead is pushed
firmly home. Under no circumstances should the cover be removed unless
the mains supply has been disconnected at the wall socket.
that it may be repacked correctly if it ever becomes necessary to ship the
unit or return it for service.
packed and returned to the dealer from whom it was purchased. It is
essential to include a covering letter giving your name and address, and a
brief but thorough explanation of the fault.
connectors. The phono sockets for left and right channels are marked
accordingly. Your interconnect cables should be marked left and right or
coburct^ed, usually red for right channel and black for left. Before
connecting your Delta 100, please ensure that all components are switched
off.
The cores of this lead are colour coded in accordance with
Green & yellow Earth
Blue Neutral
Brown Uve
Note: Export units for certain markets have moulded mains
The wire which is colour-coded green and yellow must be
FUSES
If the mains plug is fused, fit a 3 amp fuse. The AC supply
Notice: 1. Please retain the carton and all packaging so
2. If servicing is required, the equipment should be properly
CONNECTIONS
Both audio inputs andoutputs are via RCA phono
Arcam Delta 100 cassette deck handbook
the right hand meter the 10kHz tone. For a flat frequency response these
levels must be equal. Because it is impractical to read levels of -20dB
accurately on the normal meter scales, a precise 20dB of gain is applied to
the meter circuits in the calibration mode. In addition an offset is applied to
the meter circuit in this mode so that the level change represented by each
meter segment around the OdB martt is reduced to approximately 0.5dB.
Using the BIAS and CALIBRATE controls it is then easy to match the replay
levels of the two tones to within 0.25dB. This will ensure an overall
record/replay response flat to well within +/- ldB over the range 40Hz to
15kHz for any tape close to the lEC standard.
CHECK LIST
check the following before suspecting a fault;
If you have any difficulty operating your cassette deck,
IF THE TAPE DOES NOT RUN:
Check fhe cassette compartment is closed correctly.
Check fhe tape is not too tightly wound.
IF THE TAPE STOPS BEFORE REACHING THE END
DURING REWIND AND / OR FAST FORWARD:
Check fhe MEMORY function is switched off.
Check fhe tape is not too tightly wound.
NO OUTPUT DURING RECORDING OR PLAYBACK:
Check CAL TONE is switched off.
Check MONITOR is set to the correct position.
Check the record level or output level is set correctly.
Check all connections have been made correctly.
DULL HIGH FREQUENCIES - UNNATURAL SOUND:
Check fhe heads and transport mechanism for deposits of
oxide or dust. Clean if necessary.
Wrong bias setting for tape in use. Use the calibration
procedure to correct Ihis.
Demagnetize the deck if it has been in use for approx. 50
hours or more since the last demagnetization.
Check the correct Dolby NR system has been selected.
UNEVEN SOUND ■ DROP OUTS ■ EXCESSIVE WOW
AND FLUTTER:
Check the heads and transport mechanism for deposits of
oxide or tape binder. Clean if necessary with isopropyl
alcohol.
Check the quality of the tape. Avoid using very old or poor
quality tapes.
TECHNICAL SPECIFICATION
Number of motors
Number of heads
Tape speed
Wow and flutter
Fast forward/rewind time
Frequency response, 70 nsec
Distortion at 400 Hz
Signal to noise ratios, 70 psec
0.04% wrms, +/- 0.07% w peak
approx. 90 secs. (C60)
20Hz-20kHz +/- 3 dB
<1% ref- Dolby level (200 nWb/m)
66 dB. NR off
88 dB, Dolby SNR on
>40 dB at 1 kHz
300 Hz +10 kHz, at -20 dB
ref- Dolby level
100 mV (at OdB)
10 k Ohm
1 V (atOdB)
150 Ohm
105 kHz
20 VA
240/220/120/110 VAC
100V to special order
430 Wx124Hx340 D mm.
8 kg ine. packing
2 years
Arcam Delta 100 cassette deck handbook
GUARANTEE FOR OVERSEAS SALES
guaranteed by the distributor for that country only. For further details, please
contact your distributor.
these tests was made before despatch from the factory. Both the
workmanship and the performance of this equipment are (except as set out
below) guaranteed against defects for a period of two years from the date of
purchase, provided that it was originally purchased from an authorised UK
dealer under a consumer sale agreement. (The words "consumer sale’ shall
be construed in accordance with Section 15 of the Supply of Qo^s [Implied
Terms] Act 1973).
arising from accident, misuse, abuse, wear and tear, neglect or through
unauthorised adjustment and/or repair. Neither can they accept
responsibility for loss or damage occuring during transit to or from the
person claiming under this guarantee. Please note that heads, capstans,
pinch rollers and mechanical parts subject to wear and tear are not covered
by the guarantee.
transferable to subsequent purchasers, but the liability of the manufacturer
is limited to the cost of repair or replacement (at the discretion of the
manufaciu rer) of the defective parts. Under no circumstances does this
extend to consequential loss or damage.
and returned to the dealer from whom it was purchased. If this is not
possible, please contact the factory. If the original packaging Is not
available, replacement cartons and packing may be purchased from the
manufacturer. If this unit needs to be returned to the factory, please send rt
via a reputable carrier. This equipment should NOT be sent by post.
UNLESS YOU HAVE BEEN SPECIFICALLY REQUESTED TO DO SO.
DO NOT UNDER ANY CIRCUMSTANCES ATTEMPT TO DISASSEMBLE
THIS EQUIPMENT BEFORE DESPATCHING IT.
Equipment purchased outside the UK is generally
GUARANTEE FOR UK SALES
This equipment has been fully tested, and a full record of
The manufacturer can accept no responsibility for defects
This guarantee covers both parts and labour, and is
CLAIMS UNDER THIS GUARANTEE
This equipment should be packed in its original packaging,
DO NOT CONSIGN THIS EQUIPMENT TO ARCAM
requirements, please contact the manufacturer at the following address:
and a brief but thorough description of the fault.
put on test and found to comply with the published spedtication, the
manufacturer reserves the right to charge a reasonable fee for testing and
returning the unit.
regarding the use of this, or any other Arcam item. Please send your
enquiry to the above address, enclosing a stamped addressed envelope.
Please state (if applicable) the serial number of your unit, the dealer from
whom it was purchased, and the date of purchase.
licence from Dolby Laboratories Licensing Corporation. "Dolby" and the
double D symbol are trademarks of Dolby Laboratories Licensing