Congratulations on purchasing your new product from Home Appliances.
To register your Parts and Labour Warranty, some conditions apply, please refer to your warranty card for more details
and contact our Customer Care team on:
1800 444 357
Our Customer Care Centre is there to ensure you get the most out of your appliance. Should you want to learn more
about your product and how to use it to its best potential or tips on cleaning, please feel free to call us on the above
number.
It is important that you read through the following instruction manual thoroughly to become familiar with the installation
and operation of this appliance and ensure optimum performance.
We also carry a complete range of spare parts for all Home Appliance products. For all your spare parts enquiries
please contact our team at Pronto Parts on
1300 306 973
Again, thank you for choosing an appliance brought to you by Home Appliances and we look forward to being of
service to you.
Kind regards,
The Management
Home Appliances
Page 3
Built-in Stainless Steel Gas
Maintenance and troubleshooting----------------- 11
2
This manual explains the proper installation and use of your appliance, please read it
carefully before using even if you are familiar with the product. The manual should be kept
in a safe place for future reference. In case of failure, only the Authorized Technical
Service may repair this hob. Otherwise the guarantee will be null and void.
Cooktop
Warning
! Do not heat an empty pan on the appliance.
Children’s Safety
! The cooking zones will become hot when you
cook. Therefore, always keep small children
away from the appliance.
! The appliance is not intended for use by
young children or infirm persons without
supervision.
! Young children should be supervised to
ensure that they do not play with the
appliance.
Safety During Use
! There is the risk of burns from the appliance if
Safety instructions-------------------------------------- 3
Product description------------------------------------- 4
Installation------------------------------------------------ 6
Start using your appliance---------------------------- 9
General Safety
!
The appliance may only be installed and connected
by licensed gasfitters / authorized persons.
! Built-in appliances may only be used after they have
built in to suitable built-in units and work surfaces
that meet local authority standards.
! Repairs to the appliance must only be carried out by
trained registered authorized service persons /
engineers.
! The technical and identification data for the hob is
located on the reference data plate fixed to the
underside of the appliance.
! This reference data plate must be consulted before
making the electrical connections.
! The electrical connections must be made by
specialist installers to the legal and regulatory,
requirements in each country.
! If the cable is damaged in any way it must be
replaced by the manufacturer or after sale service
or by authorized technical staff, to avoid hazard.
Correct Use
! People (including children) who, because of their
physical, sensory or mental capabilities or their
inexperience or ignorance are not able to use the
device safely, should not use this device without
supervision or instruction by a responsible person.
! This appliance should be used only for normal
domestic cooking and frying of food.
! The appliance must not be used as a work surface
or as a storage surface.
! Additions or modifications to the appliance are not
permitted.
! Do not place or store flammable liquids, highly
inflammable materials or fusible objects (e.g. plastic
film, plastic, aluminum) on or near the appliance.
Page 4
3
Safety Instructions
4
26.0MJ/h
Safety When Installation
! DO NOT USE OR STORE FLAMMABLE
MATERIALS IN THE APPLIANCE STORAGE
DRAWER OR NEAR THIS APPLIANCE.
! DO NOT SPRAY AEROSOLS IN THE VICINITY
OF THIS APPLIANCE WHILE IT IS IN
OPERATION.
! WHERE THIS APPLIANCE IS INSTALLED IN
MARINE CRAFT OR CARAVANS, IT SHALL
NOT BE USED AS A SPACE HEATER.
! This hotplate must be installed in accordance
with:
AS 5601 - Gas Installations (for Australia) –
current edition
NZS 5261 – Code of Practice for the Installation
of Gas Burning Appliances and Equipment (for
New Zealand) This standard may not be now
current!!
Local gas fitting regulations
AS/NZS 3000 – Electrical Installations (Wiring
Rules)
Building codes
Any other relevant statutory regulations.
! Check the gas type label on the underside of the
hotplate, adjacent to the gas connection to
ensure it corresponds to the installation gas
supply. If in doubt contact the supply authority.
Disposing Of The Device
When disposing of the device, do not bring it to regular municipal waste containers. Instead, bring
it to electrical and electronic waste recycling and reuse center. A relevant label has been put on the
device, its instructions manual, or the package. The device has been manufactured of recyclable
material. By bringing old device to recycling collection center, you show that you care about nature.
Ask your local environmental care authority for information on location of such facilities.
! The power supply cord (supplied) must not touch
against any hot surfaces and must be placed so
that its temperature does not exceed 75 degrees
at any point along its length.
! After connecting to gas, check for leaks using
soapy solution, never a naked flame.
! Where a flexible hose assembly is used, ensure
it is approved to AS/NZS 1869, Class B 10mm
diameter and no more than 1.0metre in length.
Any hose assembly used must be restrained
from accidental contact with the flue outlet of an
under bench oven.
How To Avoid Damage To The Appliance
! Do not use the cooking zones with empty
cookware or without cookware.
! The ventilation gap of 5mm between the worktop
and front of the unit underneath it must not be
covered.
! DO NOT MODIFY THIS APPLIANCE.
Safety When Cleaning
! For cleaning, the appliance must be switched off
and cooled down.
! For safety reasons, the cleaning of the appliance
with steam jet or high pressure cleaning
equipment is not permitted.
Product Description
Burner
GHS604A-G2CI
Pan support
Panel
knobs
No. Model Burner* FSD Pan
supports
1 GHS604A-G2CI 1W+2SR+1A With 2 types for
option
2 GHS604B-G2CI 1R+2SR+1A With 2 types for
option
3 GH614AS-G2CI 1W+2SR+1A With 2 types for
option
4 GH614BS-G2CI 1R+2SR+1A With 2 types for
option
*Note:
For burner: W=Triple Ring Wok burner, R=Rapid burner, SR=Semi-Rapid burner, A=Auxiliary
burner
Knob
position
Front LPG:
Front LPG:
Right LPG:
Right LPG:
Total gas
consuption
30.5MJ/h
NG:
29.5MJ/h
27.5MJ/h
30.5MJ/h
NG:
29.5MJ/h
27.5MJ/h
NG:
26.0MJ/h
Over
view
NG:
Page 5
5
Accessory
6
TO BE INSTALLED ONLY BY AN AUTHORIZED
PERSON.
Name
User Manual 1
Sealing tape 1 roll
Additional
labels
Installation
clip
Screws
ST4.2x24
LPG Injectors
( for reference only, physical unit maybe different)
You have additional rating label in accessory bag, suggest
attach it onto a surface where it can be read e.g. inside
surface of adjacent cupboard
Picture
Quantity
1 set
4 sets
4 pcs
4 pcs
Installation
Before Installation:
! Before cutting into any bench tops, ensure the minimum clearances to walls, adjacent surfaces and
overhead surfaces required by the relevant gas appliance installation code (see above) will comply.
Dimensions are specified in millimeters (mm)
Overhead cupboards and range hood = 650 mm.
Side and rear clearance = 200 mm to any burner edge.
Overhead exhaust/ceiling fan = 750 mm
Horizontal surfaces adjacent the hob = less than or equal to the hob height.
Ensure there is sufficient clearance to fit the regulator and/or flexible hose connection with the hotplate in
the installed position.
When you have installed the hob, make sure that
! The GPO(general purpose outlet) must always be in an accessible position.
! The supply connection point, test point and natural gas regulator adjustment screw (for Natural gas
installation) are accessible for testing and/or adjustment with the hotplate in the installed position.
Elbow
&Washers
Natural gas
regulator
Technical Specifications
Model
GHS604A-G2CI
GHS604B-G2CI
Product
Dimensions
(h x w x d) mm
120x580x500 563 x 483 12.5Kgs 220-240V/50Hz 0.5W
120x580x500 563 x 483 12.5Kgs 220-240V/50Hz 0.5W
Cut-out
Size
( w x d)mm
App’x net
weight
1 Elbow, 3 washers
1
Electrical
Connection
GH614AS-G2CI 120x580x500 563 x 483 12.5Kgs 220-240V/50Hz 0.5W
1. Cupboard Cutting
Rated
Input
Power
GH614BS-G2CI
120x580x500 563 x 483 12.5Kgs 220-240V/50Hz 0.5W
Page 6
7
2. Place Burner Box
8
Apply the adhesive sealing tape to the underside lip of the burner box. Shown at G opposite.
Place burner box into cutout hole and fit clamping brackets to clamp the hotplate to the bench.
After having installed the hotplate, the GPO must always be in an accessible position.
3. Fit Burners And Trivet.
Replace burners and ensure they are correctly repositioned over the ignitor (S) and thermocouple (T). The ignitor
(S) must be clean for trouble free sparking. Test burner ignition and burner flame for correct operation, If burner
is placed correctly it will not rotate on its supports
..
The Triple Ring (Wok) burner (diagrams below) does not fit over the igniter or thermocouple but must be placed
on its supports. Make sure trivet is fitted onto its locator on burners and can’t rotate after assembled.
3. Electrical Connection
Install a 10 amp general purpose outlet (GPO) in accordance with relevant electrical standards and/or codes of
practice applicable.
The power supply cord (supplied) must not touch against any hot surfaces and must be placed so that its
temperature does not exceed 75� at any point along its length.
Wiring diagram
4. Gas Connection
Install in accordance with relevant gas standards and/or codes of practice applicable.
Connect the elbow fitting to the appliance gas manifold connection, and check that seals between the elbow and
manifold connection are in place and in good condition.
! For Natural gas: connect the natural gas appliance regulator (pictured opposite) with integral test point using
approved gas thread tape or compound to the elbow fitting.
! For Universal LPG: change the natural gas regulator to LPG set by adjusts the
spring to make sure the outlet pressure be set at 2.75kPa.
Ensure the supply connection point, test point and natural gas regulator adjustment
screw (for Natural gas installation) are accessible for testing and/or adjustment with the
hotplate in the installed position.
Where a flexible hose assembly is used, ensure it is approved to
AS/NZS 1869, Class B. Any hose assembly used must be restrained
from accidental contact with the flue outlet of an under bench oven.
This hose assembly shall be suitable for connection to a fixed
consumer piping outlet located as follows:
Hotplates at a point 800 mm to 850 mm above the floor and in the
region outside the width of the appliance to a distance of 250 mm.
After connecting to gas, check for leaks using soapy solution, never a
naked flame.
Inlet connection region for flexible hose
Fit the duplicate data plate (supplied in separate bag) on a surface adjacent to the hotplate, for example, the
inside of the cupboard door so it is clearly visible for any service technician.
SETTING THE GAS PRESSURE:
Fit a manometer with a 6 mm rubber hose to the test point on the regulator (for natural gas).
Light Triple Ring and Auxiliary burner on and adjust test point pressure to 1.00 kPa. Turn the two burners off and
on again and recheck the pressure is same as set previously or adjust as required.
TEST FOR CORRECT OPERATION:
After installation and adjusting burner pressure using test point, each burner ignition and operation must be
tested individually and with all burners operating. This testing must be done by the installer before leaving.
Page 7
9
ADJUSTING THE BURNER MINIMUM FLAME HEIGHT:
by a qualified person. Once the nozzles have
by a qualified person. Once the nozzles have
10
NOTE: This adjustment can only be performed by the installer or an authorised service personnel.
The minimum burner flame is factory adjusted for the gas type stated on the gas type label adjacent to the gas
connection and should not require adjustment. Adjustment may be required if the hotplate has been converted
from Natural gas to Universal LPG or vice versa.
GAS CONVERSION INSTRUCTIONS:
The manufacturers servicing instructions detail how authorised personnel may convert the hotplate from Natural
gas to Universal LPG or from Universal LPG to Natural gas. Contact the manufacturer or agent as required.
ADJUSTED FOR NATURAL GAS 1.0kPa
NOZZLES
DIAMETER
WOK 1.70 13.0 WOK 0.98 13.0
Rapid 1.40 9.5 Rapid 0.90 10.0
SEMI RAPID 1.10 6.0 SEMI RAPID 0.77 6.75
AUXILIARY 0.90 4.5 AUXILIARY 0.55 4.0
Replacement of the nozzles must be performed
been replaced this label must to be affixed to the
name plate of the appliances.
Natural Gas regulator is to be fitted and adjusted
mm
Gas consumption,
MJ/h
Replacement of the nozzles must be performed
been replaced this label must to be affixed to the
name plate of the appliances.
ADJUSTED FOR ULPG 2.75KPa
NOZZLES
DIAMETER
Change the NG regulator to LPG by a qualified
mm
person.
Gas consumption,
MJ/h
Start Using Your Appliance
GHS604A-G2CI, GHS604B-G2CI
Description Explanation
These show which zone is under control.
Zone indicators
Flame power
The hotplates are fitted with mains powered electronic spark ignitors, so must be connected to mains power
supply (i.e. nominal 220~240 V ac) to operate. If power is not available, the hotplate will still work but the burners
will have to be lit with a match or similar.
Depressing the gas control knob of any burner will activate the spark ignition for all burners. To light the burner,
turn the gas control knob to the High Flame setting of the burner to be lit, while at the same time depressing the
gas control knob to activate the spark ignition.
Once the burner is alight continue to depress the gas control knob for 5 – 10 seconds to allow the flame
safeguard to activate. If when you release the gas control knob, the burner flame goes out the flame safeguard
has not heated up enough so repeat the ignition procedure after waiting 1 minute for gas to disperse. If problems
with burner lighting persist, refer to the TROUBLESHOOTING section of these instructions.
If power is not available, light a match or similar, then turn the gas control knob for the burner to be lit, to the
High Flame setting. Once again if problems with burner lighting persist, refer to the TROUBLESHOOTING
section of these instructions.
Flame power of the zones, is the lowest and
is the highest.
GH614AS-G2CI, GH614BS-G2CI
When burner lights, adjust desired flame height. On finishing, turn control knob to off position marked with a
black DOT.
BURNER AND UTENSIL CHOICE
The maximum utensil (pan) diameters in millimeters
(mm) for each burner are:
1. For Natural Gas hotplates
Auxiliary (small) and Semi-Rapid (medium) =
195 mm
Rapid (large) = 230 mm
Triple ring (wok) = 270 mm
2. For Universal LPG hotplates
Auxiliary (small), Semi-Rapid (medium) and
Rapid (large) = 195 mm
Triple ring (wok) = 230 mm
The minimum utensil (pan) diameters in millimeters
(mm) for each burner are:
Auxiliary (small) = 80 mm
and Semi-Rapid (medium) = 140 mm
Rapid (large) and Triple ring (wok) = 195 mm
For best efficiency and to ensure utensil handle does
not overheat, place the utensil centrally on the burner
and adjust the flame height so all the flame remains
under the utensil.
Page 8
11
Maintenance & Troubleshooting
12
Burner not lighting when
Burner goes out when
Uneven flame pattern or
Small flame on High
Refer to operating instructions utensil
Flame too high on High
Refer to operating instructions utensil
Cleaning and maintenance should be carried out with
the appliance cold especially when cleaning the
enameled parts. Avoid leaving alkaline or acid
substances(lemon juice, vinegar etc.) on the surfaces.
STAINLESS STEEL
The stainless steel hob of the hotplate must be
cleaned regularly (e.g. weekly) to ensure long
life expectancy of the hotplate.
Ensure hotplate has cooled. Wash down with warm
soapy water and rinse with clean water.
Dry with a clean soft cloth. A specialized stainless
steel cleaning fluid may be used.
NOTE: Ensure that wiping is done along with the
grain of the stainless steel to prevent any unsightly
crisscross scratching patterns from appearing.
TRIVETS (UTENSIL SUPPORTS)
Enameled parts must only be washed with a sponge
and soapy water or with non-abrasive products. Rinse
with clean water. Dry with a clean soft cloth.
BURNERS
Remove trivets from
hob. Ensure burners
are cool. Remove the
burners enameled
cap (C) and aluminum
burner crown (F).
Wash down with
warm soapy water
and rinse with clean
water. Dry with a
clean soft cloth.
Note: S: Ignition pin T: Thermocouple
Use a cotton bud, tooth brush, or some other item to
clean out any incrustations or dirt from the four holes
marked(H)
The spark gas is 4-6mm.
Replace burners and ensure they are correctly
repositioned over the igniter (S) and thermocouple (T).
The igniter (S) must be clean for trouble free sparking.
Test burner ignition and burner flame for correct
operation.
The Triple Ring (Wok) burner (diagrams below) does
not fit over the igniter or thermocouple but must be
placed on its supports. If burner is placed correctly it
will not rotate on its supports.
The surface of hob, Ignition Pin(S), Thermocouple
(T) and burners need to be cleaned after each time
they are used with warm soapy water, rinsed and
then dried well to keep them in good condition.
Never clean when the top and components are still
warm. Do not use metal or abrasive pads, abrasive
powders or corrosive spray products. Never leave
vinegar, coffee, milk, salty water, lemon or tomato
juice for any length of time on the surfaces.
• To replace gas and electrical components, that
are lodged inside the hob, it is enough to
remove the work top unscrewing the fixing
screws of the burners
• Replace the seal each time you change a tap in
order to guarantee a perfect tightness between
body and rail.
TROUBLESHOOTING
Servicing of the hotplates must only be done by an authorised service representative (see back of this booklet) and the
hotplate must not be modified. Power must be disconnected before any servicing or maintenance is conducted.
DO NOT MODIFY THIS APPLIANCE.
It is recommended the hotplate serviced by an authorized person at least every 2 years. This service is not covered by
warranty.
Abnormal conditions include:
! Excessively yellow or sooting flame type.
! Flame lifting off the burner ports.
! Flame lighting back into the burner (normally associated with a popping sound).
! Objectionable odour of the flames combustion products.
Should a faulty condition develop in the hotplate that is not described above, refer to the following table first for
possible causes and remedies prior to contacting an authorised service representative. Servicing beyond the remedies
listed shall only be undertaken by an authorised service representative.