%RH (± 5%) based on Control Knob Setting and Indoor Temperatur e
I. PRINCIPLE OF OPERATION
The purpose of the Aprilaire® Dehumidifier is to keep humidity in the house at
acceptable limits to reduce the unwanted effects of high humidity. The
dehumidifier measures the condition of the house air to decide when to run.
II. OPERATING INSTRUCTIONS
There are three adjustable settings: the dryness setting, the air cycle period
and the air cycle time within that period. The dehumidifier can be set from “1” or
“LESS DRY” to “7” or “MORE DRY” based on desired comfort level. Most
installations should be initially set to the “3” or “NORMAL” setting; however this
can be adjusted to your individual needs.
1. ADJUSTING THE DEHUMIDIFIER SET POINT
Use the main control knob (Figure 1) on
the outside of the unit to s et the
dehumidifier dryness setting. Start with a
“NORMAL” setting for most installation s.
Moving the knob clockwise to “MORE
DRY” will make conditions drier. Moving
the knob toward “LESS DRY”
higher moisture levels.
Based on the thermostat set point, use the
following table to determine the control
knob setting to reach the desired RH value. The dehumidifier will work to achieve
these values.
allows for
IV. MAINTENANCE
AIR FILTER
Under normal circumstances, the filter in the dehumidifier should be cleaned or
replaced once a year. A clea n filter is ne cessary to prev ent d amag e to the
dehumidifier and allow it to function at full capacity. To remove the filter, first
unplug or disconnect power to the dehumidifier, then remove the air filter via the
access panel on the side of the dehumidifier. To clean, flush with warm water and
detergent solution. After a clean or new filter is reinstalled, replace the access
panel and reconnect power to the dehumidifier. The replacement filter for the
dehumidifier is Model 4510 and is available from your installing contractor or from
most other HVAC contractors in your area.
DRAIN
The drain trap or outlet should be checked and cleaned of debris annually.
Flush it with water under pressure to ensure opening is clear.
4 64% 54% 45% 39%
7 - “MORE DRY” 40% 34% 28% 24%
temperature of 75°F with a
dehumidifier control knob sett i ng
of 3 - NORMAL, the dehumidifier
will work to achieve an RH value
of 53%.
1. %RH values are ±5% and are to be
used as a GUIDE ONLY for initial setup.
2. Indoor Temperature is measured at
the inlet to the Model 1700.
V. LIMITED WARRANTY
Your Research Products Corporation Aprilaire
(5) years from date of installation to be free from defects in materials or workmanship.
Research Products Corporation’s exclusive obligation under this warranty shall be to supply,
without charge, a replacement for any component which is found to be defective within such
five (5) year period and which is returned not later than thirty (30) days after said five (5)
year period by you to either your original supplier or to Research Products Corporation,
Madison, Wisconsin 53701, together with the model number and installation date of the
dehumidifier.
THIS WARRANTY SHALL NOT OBLIGATE RESEARCH PRODUCTS CORPORATION
FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN WORKMANSHIP
OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN
THE DEHUMIDIFIER ITSELF.
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID FIVE YEAR PERIOD.
RESEARCH PRODUCTS CORPORATION’S LIABI LITY FOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES, OTHER THAN DAMAGES FOR PERSONAL INJURIES,
RESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED WARRANTIES OR
THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED. THIS LIMITED
WARRANTY IS VOID IF DEFECT(S) RESULT FROM FAILURE TO HAVE T HIS UNIT
INSTALLED BY A QUALIFIED HEATING AND AIR CONDITIONING CONTRACTOR. IF
THE LIMITED WARRANTY IS VOID DUE TO FAILURE TO USE A QUALIFIED
CONTRACTOR, ALL DISCLAIMERS OF IMPLIE D WARRANTIES SHALL BE EFFEC TIVE
UPON INSTALLATION.
Some states do not allow limitations on how long an implied warranty lasts or the exclusion
or limitation of incidental or consequential damages so the above exclusion or limitations
may not apply to you.
This warranty gives you specific legal rights and you may also have other rights which vary
from state to state.
WARRANTY REGISTRATION
If you do not have on-line access, please mail a postcard with your name,
address, phone number, product purchased and date of purchase to:
Your Warranty Registration information will not be sold or shared outside of
this company.
10006239 11.06
® Dehumidifier is expressly warranted for five
Please… Take a few minutes to visit us on-line at
www.aprilaire.com
to register your Aprilaire product.
Research Products Corporation
P.O. BOX 1467
Madison, WI 53701
Thank you!
B2203432BFree Standing
Dehumidifier
Model 1700FS Dehu m idifier
Owner’s Manual
Includes Safety & Operating Instructions
and Warranty Informati on
120 volts may cause serious
injury from electric shock.
Disconnect electrical power
before servicing.
READ AND SAVE THESE INSTRUCTIONS
Sudden operation may cause
personal injury or property
damage. Unplug the
dehumidifier before serv icing.