Model 1510/2516 Air Cleaner
Installation Instructions
WARNING
1. High voltage may cause serious injury from electrical shock. Disconnect power to the furnace/air handler before starting installation.
2. Sharp edges may cause injury from cuts. Use care when cutting and handling sheet metal.
CAUTION
1. To prevent component failure, do not install the air cleaner on the warm air supply or in an area where the temperature may exceed 140°F.
This may include areas above heat exchangers in downflow furnaces or above exhaust flues in lowboy furnace cold air returns.
2. Installation must be done by a qualified heating and air conditioning professional. Read instructions thoroughly before beginning installation.
3. Do not install air cleaner downstream of a UV light. UV lamps will cause degradation of the filtering media.
SPECIFICATIONS
MODEL 1510 2516
Airflow Capacity up to 3000 CFM maximum up to 2680 CFM maximum
Replacement Filter Model 510, 513 or 516 with SelfSeal™
Maximum Equipment Weight Cabinet will support 400 lb. static load
Air Cleaner Operating Environment Temperature: 0°F–140°F. Humidity: 0–90% non-condensing.
DIMENSIONS
B
WITHOUT DOOR
C
A
D
E
WITH DOOR
F
G H
90-1333
TABLE 1 – DIMENSIONS (INCHES)
Model A B C D E F G H
1510 & 2516 28-3/4 28-1/16 23-7/8 6-3/4 30-1/16 23-7/8 28-3/4 31
English 1
INSTALL THE AIR CLEANER CABINET
LOCATING THE AIR CLEANER
1. Leave sufficient space in front of the air cleaner for the removal of the filter (see FIGURE 1).
2. DO NOT INSTALL DOWNSTREAM OF A UV LIGHT. UV lamps will cause degradation of the filtering media.
3. FIGURE 1 shows typical application of the air cleaner mounted to a horizontal system.
4. FIGURE 2 shows the air cleaner mounted to the side of a geothermal heat pump.
FIGURE 1 FIGURE 2
45° MAX
AIR FLOW
29"
10-10998 90-1769
2 English
INSTALLATION
1. Disconnect power to the furnace or air handler at
the electrical service panel.
WARNING
120 Volts may cause serious injury from electrical
shock. Disconnect power to the furnace/air
handler before starting installation. Leave power
disconnected until installation is completed.
2. Remove the air cleaner door from the outer
housing and pull out the filter (see FIGURE 3).
3. If replacing an existing filter, remove the filter and
thoroughly clean the blower compartment.
4. Use screws (field supplied) to mount the outer
housing to the furnace/air handler. There is no
inlet or outlet side on the outer housing (the outer
housing can be mounted on the left or right side
of the furnace/air handler).
5. Mount the return ductwork to the outer housing.
FIGURE 3
90-2345
FIGURE 4
6. Seal all connections using mastic, foil tape or
silicone based caulk.
7. Install the filter (see FIGURE 4).
8. Install the door.
9. Reconnect power to the furnace or air handler at
the electrical service panel.
EXPAND
CLEAN FILTER.
INSTALL FILTER WITH AIR FLOW POINTING
TOWARD FURNACE OR AIR HANDLER.
ALIGN FILTER IN TOP AND BOTTOM RAILS
AND SLIDE INTO PLACE. REINSTALL DOOR.
90-2344
90-2346
English 3
AprilairePartners.com
P.O. Box 1467
Madison, WI 53701-1467
800.334.6011 F: 608.257.4357
Printed in USA
©2020 Aprilaire – Division of Research Products Corporation
10012856 B2701481B 1.20