Models 1213 & 1413
Upgrade Kit for Media Air Cleaners
Installation Instructions
WARNING
Sharp edges may cause injury from
cuts. Use caution when handling
sheet metal.
APPLICATION
Fits all Model 2400 air cleaners and
Model 2200 air cleaners produced after 1985
(see illustrations at right).
CAUTION
1. Read instructions thoroughly before beginning installation.
2. Do not install the upgrade kit in a location where the media will be
in direct exposure to UV light. UV lights will cause degradation of the
fi ltering media.
CONTENTS OF PACKAGE
NOTE: Door liner is in the bottom of
the box – do not discard.
MODEL 2400
OLD STYLE
MODEL 2400
NEW STYLE
STYROFOAM
DOOR LINER (QTY 1)
MODEL 2200
OLD STYLE
FILTER MEDIA (QTY 1)
FRAME BASE (QTY 2)
FRAME SUPPORT (QTY 4)
MODEL 2200
NEW STYLE
90-1377
DOOR LABEL (QTY 1)
IN STA LL ATI ON
INSTRUCTIONS (QTY 1)
90-1378
INSTALLATION
1. IMPORTANT: Turn the thermostat mode to OFF and fan to AUTO.
2. Snap frame supports into frame base as shown – eight (8) places. Make sure the support slides in and hits the center
rail of the frame base.
90-1385
3. Remove the door from the air cleaner.
4. Remove and discard the inner housing assembly.
90-1379
Inner housing
assembly
90-1380
2