Air Purifiers
Installation Instructions
WARNING
1. High voltage may cause serious injury from electrical shock. Disconnect power to the furnace/air handler before starting installation.
2. Sharp edges may cause injury from cuts. Use care when cutting and handling sheet metal.
CAUTION
1. To prevent component failure, do not install the air purifier on the warm air supply or in an area where the temperature may exceed 140°F.
This may include areas above heat exchangers in downflow furnaces or above exhaust flues in lowboy furnace cold air returns.
2. Installation must be done by a qualified heating and air conditioning professional. Read instructions thoroughly before beginning installation.
3. Do not install air purifier downstream of a UV light. UV lamps will cause degradation of the filtering media.
SPECIFICATIONS
MODEL 1110 1210, 2210, 2216, 3210 1310, 2310, 3310 1410, 2410, 2416, 3410 1910
Replacement Filter
Maximum Equipment Weight
Air Purifier Operating Environment Temperature: 0°F–140°F, Humidity: 0–90% non-condensing
Model 110 or 113
with SelfSeal™
Cabinet will support
250 lb. static load
Model 210, 213, 213CBN
or 216 with SelfSeal™
Model 310 or 313
with SelfSeal™
Cabinet will support 400 lb. static load
Model 410, 413, 413CBN
or 416 with SelfSeal™
Model 910 or 913
with SelfSeal™
DIMENSIONS
B
WITHOUT DOOR
C
A
D
E
WITH DOOR
F
G H
90-1333
TABLE 1 – DIMENSIONS (INCHES)
Model A B C D E F G H
1110 15-7/16 20-1/16 17-3/8 6-3/4 22-1/16 17-3/8 15-7/16 17-3/4
1210, 2210, 2216, 3210 19-3/4 25-3/8 21-3/16 6 -3/4 27-3/8 21-3/16 19-3/4 22-1/16
1310, 2310, 3310 18-1/16 20-1/16 15-7/8 6-3 /4 22-1/16 15-7/8 18-1/16 20-3/8
1410, 2410, 2416, 3410 15-7/16 28-1/16 23-7/8 6 -3/4 30-1/16 23-7/8 15-7/16 17-3/4
1910 22-3/4 20-1/16 15-7/8 6-3/4 22-1/16 15-7/8 22 -3/4 25-1/16
English 1
INSTALL THE AIR PURIFIER CABINET
LOCATING THE AIR PURIFIER
1. Leave sufficient space in front of the air purifier for the
removal of the filter (see FIGURE 1).
2. DO NOT INSTALL DOWNSTREAM OF A UV LIGHT.
UV lamps will cause degradation of the filtering media.
3. FIGURES 2-4 show typical applications.
FIGURE 1 – FILTER CLEARANCE
FIGURE 2 – HORIZONTAL INSTALLATION
AIRFLOW
90-1319
30° MAX
AIRFLOW
SEE DIMENSION E
FIGURE 4 – UPFLOW INSTALLATION
90-1374
30° MAX
FIGURE 3 – HIGHBOY PLATFORM INSTALLATION
AIRFLOW
AIRFLOW
90-2099
PLENUM BOX
90-131890-2100
2 English
AIRFLOW
AIRFLOW
30° MAX
45° MAX
AIRFLOW
PLENUM
BOX
90-132090-210190-1320
INSTALLATION
1. Disconnect power to the furnace or air handler at
the electrical service panel.
WARNING
120 Volts may cause serious injury from electrical
shock. Disconnect power to the furnace/air
handler before starting installation. Leave power
disconnected until installation is completed.
2. Remove the air purifier door from the outer
housing and pull out the filter (see FIGURE 5).
3. If replacing an existing filter, remove the filter and
thoroughly clean the blower compartment.
4. Use screws (field supplied) to mount the outer
housing to the furnace/air handler. There is no
inlet or outlet side on the outer housing (the outer
housing can be mounted on the left or right side
of the furnace/air handler).
NOTE FOR UPFLOW INSTALLATIONS: Provide
support under the outer housing to ensure the quality
of the seals (see FIGURE 6).
FIGURE 6
90-1374
FIGURE 7
5. Mount the return ductwork to the outer housing.
6. Seal all connections using mastic, foil tape or
silicone based caulk.
7. Install the filter (see FIGURE 7).
8. Install the door.
9. Reconnect power to the furnace or air handler at
the electrical service panel.
FIGURE 5
EXPAND
CLEAN FILTER.
INSTALL FILTER WITH AIR FLOW POINTING
TOWARD FURNACE OR AIR HANDLER.
90-2345
ALIGN FILTER IN TOP AND BOTTOM RAILS
AND SLIDE INTO PLACE. REINSTALL DOOR.
90-2344
90-2346
English 3
AprilairePartners.com
P.O. Box 1467
Madison, WI 53701-1467
800.334.6011 F: 608.257.4357
Printed in USA
©2018 Aprilaire – Division of Research Products Corporation
10011245 B2701359C 1.18
4 English