Apple Performa Display.Plus Service Manual

Page 1
K
Service Source
Apple Performa Display/
Plus
Page 2
K
Service Source
Specifications
Apple Performa Display/Plus
Page 3
Specifications Characteristics - 1

Characteristics

Picture Tube

Screen Resolution

Scan Rates

Active Area

Input Signals

M37118X 14-in. diagonal shadow mask (11.9-in. viewable image)
640 x 480
Horizontal scan rate: 35.0 kHz Vertical refresh rate: 66.7 Hz
9.5 in. by 7 in. (240 mm by 180 mm)
RGB linear, all colors Composite sync TTL level
Page 4
Specifications Controls - 2

Controls

User Controls Front Panel

Power switch Brightness control Contrast control
Page 5
Specifications Physical and Electrical - 3

Physical and Electrical

Power Supply

EHT

Size

W arm-Up Time

Voltage: 120 VAC ± 10% Frequency: 60 Hz Power: 85 W
24 kV
Height: 13.75 in. (350 mm) Width: 13.75 in. (350 mm) Depth: 14.25 in. (360 mm)
30 minutes required to meet all specifications
Page 6
K
Service Source

Troubleshooting

Apple Performa Display/Plus
Page 7
Troubleshooting General - 2

General

The Symptom Charts included in this chapter will help you diagnose specific symptoms related to your product. Because cures are listed on the charts in the order of most likely solution, try the first cure first. Verify whether or not the product continues to exhibit the symptom. If the symptom persists, try the next cure. (Note: If you have replaced a module, reinstall the original module before you proceed to the next cure.)
If you are not sure what the problem is, or if the Symptom Charts do not resolve the problem, refer to the Flowchart for the product family.
For additional assistance, contact Apple Technical Support.
Page 8
Troubleshooting Symptom Charts/Geometry - 3

Symptom Charts

Geometry

Raster too short, tall, narrow, or wide
Raster not centered Replace monitor.
No raster Replace monitor.
Abnormal or distorted raster
Replace monitor.
1 Verify that distortion is not due to environmental conditions.
Move unit away from electrical equipment and shut off
fluorescent lights. 2 Adjust brightness and contrast. 3 Replace monitor.
Page 9
Troubleshooting Symptom Charts/Synchronization - 4

Synchronization

Picture breaks into diagonal lines
Picture rolls horizontally or vertically
Single vertical or horizontal line appears on black raster
Replace monitor.
Replace monitor.
Replace monitor.
Page 10
Troubleshooting Symptom Charts/Video - 5

Video

Predominant color tint
Picture too dark or too bright
Cannot adjust brightness or contrast
Replace monitor.
Replace monitor.
Replace monitor.
Page 11
Troubleshooting Symptom Charts/Miscellaneous - 6

Miscellaneous

Out of focus Replace monitor.
Out of convergence Replace monitor.
Picture jitters or flashes
Black spots appear on screen (burnt phosphors)
1 Verify that distortion is not due to environmental conditions.
Move unit away from electrical equipment and shut off
fluorescent lights. 2 Check that all ground cables are secure. 3 Replace monitor.
Replace monitor.
Loading...