APC UTS6H, BU154A, UTS10BI, UTS6 User Manual

Operation Manual
Universal Transfer Switch
UTS6
UTS6H
UTS6BI
UTS10BI
UTS10BI
Introduction
bu154a
About this product
The APC® by Schnei d er El ec tr i c Universal Transfer Switch (UTS) is a fully automatic transfer switch for use in optional standby syst ems in homes or s mall bus ines ses. This unit prov ide s safe, conveni ent powe r for up to ten circuit s in th e home or office. Power is derived from one or two independe nt bac kup sources. Backup sourc es being a generator , an uninterruptible power supply (UPS), a solar inverter, or another alternative energy source.
When connected to home appliances, computers, or entertainment equipment the backup power sources provide power during uti lity powe r out ages. Whe n a UPS is us ed in t he conf igura tion, connec ted eq uipmen t (load) , c an be pro tected fro m utility br ownouts, sags, surges, and power outages. The UPS provides continuous power from the internal batter y until utility power ret urns to safe levels or the batter y is fully discharged .
The models supported by thi s manual vary in appearance and have some variation in function.
Individual model f unctionality will be addressed in this manual.
UTS10BI
Protect your investment
Fill out the Warranty Registration Card found in th e documentation package, or register your purchas e online at www.apc.com:
• This will guarantee that the owner receive all of the information and special offers qualified for as the owner of this product.
• This will confirm the owners right to maximum protection under the Warranty terms and conditions.
• This will confirm yourself as the owner of the product in the event of fire, theft or los s.
1 Operation Manual Universal Transfer Sw it ch UTS6 UTS6H UTS6BI UTS10BI
Safety and Regulatory Information - save this information
Read the Operation Manual before operating the UTS. Read, understand, and follow the Safety Precautions in this manual.
Safety Precautions
• Adhere to all national and local electrical codes when installing, configuring and operating the UTS.
Installation of the UTS must be performed by a qualified electrician.
• Prior to installing the UTS have a qualified electrician check that the wiring in the home or office meets all local and national electrical cod es.
• This unit must be conne cte d to a properly grounded utility power source.
• Do not install or operate this unit near a source of water or in an environment where the rel ative humidity could exceed 95% (non-condensing).
• DO NOT operate a generator inside a building. Operating a generator inside a building ca n cau se death by asphyxiation.
• DO NOT allow the tot al lo ad conne cte d to the UTS to exceed the limits list ed in the Specifications sectio n of the Site Preparation and Ins tallation Guide.
• There are no user serv iceable components in this unit. Removing the cover from this unit by unqualified persons can prese nt a shock hazard and may void the warranty.
• Periodically i n spect all po w er cords to en sure:
– secure co n n ect i on s – proper routing to ensure cords are not pinched, frayed, or stepped on
• If the UTS is damaged, disconnect the main circuit breaker and contact APC at www.apc.com.
Warning: Stop using the unit immediately i f any of the following conditions arise.
•Conduit or receptacles have been damaged
•Objects have fallen into the unit
•Liquid has spilled into the unit
•The unit has been exposed to rain
•The unit has been dropped or damaged in any way
•The unit does not operate properly
Contact APC at www.apc.com, to arrange service for the unit.
Operation Manual Universal Transfer Switch UTS6 UTS6H UTS6BI UTS10BI2
UTS Configurable Features
Feature Description
Uninterruptible Power Supply
Adaptive Load Management (ALM)
Load Transfer
Time Management & Load Shedding
Voltage Sensitivity
Security Mode also refer red t o a s vacation mode
• provides UPS backup for uninterrupted operation
• provides backup power until the generator comes on line Provides automatic shut off (referred to as load shedding), of se lect circuits during blackout
conditions
• prevents power surg es and ove rload conditions from st alling a generator, or tripping circuits
• increases generator ef ficiency by 20% or more during prolonge d power outages
• automatically reconnects loads once the overload conditions have been corrected Provides automatic transfer of select loads between a generator and a UPS
• minimizing power interruptions due to overload conditions
• maximizing power availability Time management feature sets maximum and minimum times for ALM to run
Refer to the Configuration and Setup section in this manual for detailed functionality Settings determine how the UTS reacts to momentary power fluctuations
MEDIUM - factory default LOW - useful when frequent, small power fluctuations DO NOT require UTS intervention HIGH - recommended ONLY for loads that are very sensitive to small, brief power
fluctuations When security mode is set to ON, the UTS automatically cycles power to circuits at a rate of
two hours on and two hours off Recommended for use on strategic light circuits during vacations
Bypass Mode
Liquid Crystal Display (LCD)
Automatic Start/Stop Operation
During bypass mode operation all circuits utilize utility power ONLY
• Backup power sources are not utilized regardless of the quality or condition of utility power
• Overload protection re mains available during bypa ss mode operation
• During initia l setup and configura tion the LCD displays the particula r se tting or value t hat is to be entered or changed
• During regular operation the LCD is used with various LED indica tors and push buttons providing UTS status messages, warnings
• During regular operat ion the LCD is used with various LED indicators and push buttons to perform required actions
Semiautomat ic operation: The UTS automatically switches to generator power once the generator has been co nnec ted and turned on.
Fully automatic, compatib l e, r emote cont r ol l ed , au t o s t op/start ge n e ra to r s r eq u ir e :
• APC UTS Generator Hardwiring Interface Kit
• APC UTS Automatic Remote Start/Stop Kit
For ordering details contact APC through the Web site, www.apc.com.
3 Operation Manual Universal Transfer Sw it ch UTS6 UTS6H UTS6BI UTS10BI
UTS Controls and Indicators
The UTS controls and ind icators are located on the front of the UTS.
bu163a
Control or In dicator Descript i on
LCD • Displays two lines with 20 characters per line
• Displays UTS status, warnings, general info rmation
• Displays the value or setting that is being entered or changed during configuration and setup
System Status button Cycles the UTS through the default or select ed s ystem status optionsSystem Set up button Used to configure the UTS sys tem optionsCircuit Status butto n Cycles the UTS through the circuits displaying the status of each on the LCDCircuit Setup button Used to configure the UTS individual circui t optionsDown/Up arrow buttons Used to scroll through steps for configuration and to scroll between status and
informational displays
Source LEDs
Utility Generator UPS
• Solid green LED illum ination indicates that the power source is ON and is functioning normally
• No LED illumination indicates that the power source is OFF or is outside specif i ed limits
• A flashing gre en LED indicates that a fault condition exists f o r that power source, and should be correc ted
Circuit LEDs The number of circuit LEDs varies dependent on the model of UTS
• Red LED illumination indicates that the UTS circuit is receiving power from one of the power sources
• No illumination indicates that circuit is receiving no power
• A flashing red LED indic ates that a fault condition exists and sho uld be corrected
Operation Manual Universal Transfer Switch UTS6 UTS6H UTS6BI UTS10BI4
UTS circuit LED configurations
120 V
1 3 5
120 V
240 V
1 3 5
120 V
240 V
1 3 5 7
9
bu164a
UTS6/UTS6H
Circuit
2 4 6
120 V circuits ONLY
Together , circuits 5 and 6 form a dedicated
UTS6BI
Circuit
240 V circuit. DO NOT use these circuits as individual 120 V circuits.
UTS Power Connectors
The power connectors are located on the front of the UTS.
UTS10BI
UTS10BI
Circuit
2 4 6
2 4 6 8
10
Together, circuits 9 and 10 form a dedicated 240 V circuit. DO NOT use these circuits as individual 120 V circuits.
• Generator inlet is hardwired. Conn ection must be in a remote, out door location. Refer to the
Connect UTS to Backup Power Sources section in the Site Preparation and Installation
Generator Inle t
Guide.
• Refer to the Site Prepa r ation and Install ation Guide for specifica tions concerning th e generator power cable.
UPS Inlet IEC 320 connector for UPS power cable.
• NEMA 5-15, 120 V convenience outlet for connecting a UPS or another selected load.
• Convenience outlet utilizes utility power or generator powe r.
Convenience Out l et
• If any circuits are to be configured as uninterruptible, a UPS must be used as the Backup2 power source. The UPS input cord should plug into the convenience outlet to all ow the UPS battery to charge while operating on generator power.
5 Operation Manual Universal Transfer Sw it ch UTS6 UTS6H UTS6BI UTS10BI