APC Smart-UPS SC SRC1KI, Smart-UPS SC SRC2KI APC Smart-UPS SC SRC2KI.pdf

Page 1

User Manual Smart-UPS™ On-Line SRC1KI, SRC2KI, SRC1KI-AR, SRC2KI-AR

Important Safety Information

Read the instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service or maintain it. The following special messages may appear throughout this document or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure.
The addition of this symbol to a Danger or Warning product safety label indicates that an electrical hazard exists that will result in personal injury if the instructions are not followed.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
DANGER
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
NOTICE is used to address practices not related to physical injury.
Page 2

Safety and General Information

Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage.
• This UPS is for indoor use only.
• Do not operate this UPS in direct sunlight, in contact with fluids, or where there is excessive dust or high humidity.
• Do not operate the UPS near open windows or doors.
• Be sure the air vents on the UPS are not blocked. Allow adequate space for proper ventilation. Note: Allow a minimum of 20 cm clearance on all four sides of the UPS.
• Environmental factors impact battery life. Elevated ambient temperatures, poor quality utility power, and frequent discharges will shorten battery life. Follow the battery manufacturer recommendations.
Electrical safety
• Connection to the branch circuit (mains) must be performed by a qualified electrician.
• The protective earth conductor for the UPS carries the leakage current from the load devices (computer equipment). An insulated ground conductor is to be installed as part of the branch circuit that supplies the UPS. The conductor must have the same size and insulation material as the grounded and ungrounded branch circuit supply conductors. The conductor will be green and with or without a yellow stripe.
• The grounding conductor is to be grounded to earth at the service equipment, or if supplied by a separately derived system, at the supply transformer or motor generator set.
• Ensure that a recommended utility circuit breaker is installed at the UPS input.
SRC1KI/SRC1KI-AR SRC2KI/SRC2KI-AR
8 A 13 A
Smart-UPS On-Line SRC1KI/2KI, SRC1KI-AR/2KI-AR2
Page 3
Battery safety
• Do not dispose of batteries in a fire. The batteries may explode.
• Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes, and may be toxic.
• Schneider Electric uses Maintenance-Free sealed Lead Acid batteries. Under normal use and handling, there is no contact with the internal components of the battery. Over charging, over heating or other misuse of batteries can result in a discharge of battery electrolyte. Released electrolyte is toxic and may be harmful to the skin and eyes.
• CAUTION: Before installing or replacing the batteries, remove jewelry such as wristwatches and rings. High short circuit current through conductive materials could cause severe burns.
• CAUTION: Do not dispose of batteries in a fire. The batteries may explode.
• CAUTION: Do not open or mutilate batteries. Released material is harmful to the skin and eyes and may be toxic.

Radio Frequency Warning

This product has been tested and found to be category C2 device. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment is likely to cause radio interference with some communication devices like TV, mobiles, audio equipments, radio receivers, etc. Generally this issue can be corrected by moving the equipment a little away from the UPS, however sometimes additional measures may have to be taken at user's expense.

Product Description

The APC by Schneider Electric Smart-UPS™ is a high performance uninterruptible power supply (UPS). The UPS helps to protect the connected electronic equipment from utility power blackouts, brownouts, sags, surges, small utility power fluctuations and large disturbances. The UPS also provides battery backup power for connected equipment until utility power returns to normal levels or the batteries are discharged.
This user manual is available on the APC by Schneider Electric Web site, www.apc.com.
Smart-UPS On-Line SRC1KI/2KI, SRC1KI-AR/2KI-AR
3
Page 4

Package Contents

Read the Safety Guide before installing the UPS.
The packaging is recyclable; save it for reuse or dispose of it properly.
• UPS • Literature kit containing: – Product documentation – Safety information
All Models SRC1KI / SRC2KI SRC1KI-AR / SRC2KI-AR
USB cable: Used to connect UPS to computer/laptop for PCBE monitoring
RS232 cable
Utility power cable
Output cable (2x)
Utility power cable (3x)
NOTE: The model and serial numbers are located on a small, rear panel label.

Optional Accessories

Refer to the APC by Schneider Electric Web site, www.apc.com, for available accessories.
Smart-UPS On-Line SRC1KI/2KI, SRC1KI-AR/2KI-AR4
Page 5

Specifications

Environmental specifications
NOTICE
RISK OF EQUIPMENT DAMAGE
• UPS must be used indoors only.
• The installation location should be sturdy to withstand the weight of the UPS.
• Do not operate UPS where there is excessive dust or where the temperature or humidity are outside specified limits.
Failure to follow these instructions can result in equipment damage.
Temperature Operating 0° to 40°C at rated load
40° to 50°C linearly derated to 80% of maximum load capacity
Storage -20° to 50°C
Elevation Operating 0 - 1,000 m: normal
operation 1,000 - 3,000 m: The load reduces @ 1% at an increased height of every 100 m > 3,000 m: UPS will not work
Storage 0 - 15,000 m
Humidity 0 to 95% relative humidity,
non-condensing
This unit is intended for indoor use only. Select a location sturdy enough to handle the weight. Do not operate UPS where there is excessive dust or where the temperature or humidity are outside specified limits.
Note: Charge the battery modules every six months during storage.
Smart-UPS On-Line SRC1KI/2KI, SRC1KI-AR/2KI-AR
5
Page 6
Physical specifications
The UPS is heavy.
< 18 kg (< 40 lb) 18 - 32 kg (40 - 70lb)
Follow lifting guidelines.
UPS model SRC1KI / SRC1KI-AR SRC2KI / SRC2KI-AR
Dimensions with packaging Width x Height x Depth
Dimensions without packaging Width x Height x Depth
Weight with packaging
Weight without packaging
230 mm (9.05 in) x 355 mm (14 in) x 510 mm (20.1 in)
220 mm (8.66 in) x 145 mm (5.7 in) x 400 mm (15.75 in)
12.4 kg 19.8 kg
10.7 kg 18 kg
230 mm (9.05 in) x 355 mm (14 in) x 590 mm (23.2 in)
220 mm (8.66 in) x 145 mm (5.7 in) x 504 mm (19.8 in)
Input specifications
UPS model
Nominal input voltage 230 Vac
Input frequency 40 - 70 Hz
Input cable 10 A, 1.5 m
SRC1KI / SRC1KI-AR SRC2KI / SRC2KI-AR
Input voltage range (100% load)
Input voltage range (50% load) 140 Vac - 295 Vac
Input power factor (100% resistive load)
Input protection Thermal circuit breaker
Smart-UPS On-Line SRC1KI/2KI, SRC1KI-AR/2KI-AR6
190 Vac - 295 Vac
0.99 in Green mode
0.93 in Normal mode
Page 7
Output specifications
UPS model
Output power capacity max. 1000 VA / 800 W 2000 VA / 1600 W
Nominal output voltage 230 Vac
Other programmable voltages 220 Vac, 230 Vac and 240 Vac
Efficiency at rated load 88% max.
Output voltage regulation ± 1% static
Output voltage distortion • 3% max. for full linear load,
Output frequency battery mode 50/60 Hz ± 0.5%
Output frequency AC mode 50/60 Hz ± 3 Hz
Crest factor 3:1
Waveform Sinewave
Bypass Internal bypass
SRC1KI / SRC1KI-AR SRC2KI / SRC2KI-AR
• 6% max. for full RCD load (100% VA, 0.8 PF)
• 15% for the last 60 seconds of the backup time (with full load only for the internal battery)
Battery
UPS model
Configuration Internal battery
Type Sealed maintenance free (SMF) 12 V, 9 Ah
Battery bank voltage 24 V 48 V
Smart-UPS On-Line SRC1KI/2KI, SRC1KI-AR/2KI-AR
SRC1KI / SRC1KI-AR SRC2KI / SRC2KI-AR
7
Page 8

Rear Panel Features

suo11
suo1196a
suo12
SRC1KI SRC2KI
95a
SRC1KI-AR / SRC2KI-AR
39a
Utility power cable connector  USB port
Input thermal circuit breaker reset
button
SmartSlot for management accessories
Battery connector
Emergency Power Off (EPO) Battery backup plus surge arrest outlets
Serial com connector  Ground screw
Smart-UPS On-Line SRC1KI/2KI, SRC1KI-AR/2KI-AR8
Page 9

Start Up

Connect the battery
Pull the battery connector handle up, and then push it into the unit.
Connect equipment and input power to the UPS
CAUTION
HAZARD OF ELECTRIC SHOCK
• All electrical work must be performed by a qualified electrician.
• Turn off all power to this equipment before working on the equipment. Practice lockout/tagout procedures.
• Do not wear jewelry when working with electrical equipment.
Failure to follow these instructions can result in minor or moderate injury.
1. Connect equipment to UPS. Avoid using extension cords.
2. Connect input utility power to the UPS.
3. Switch the utility input power on. The display panel will illuminate when utility power is available.
Start the UPS
Press the POWER ON/OFF button located on the front panel of UPS.
Cold start the UPS
Use cold start feature to supply power to connected equipment from the UPS batteries.
Press the
Press the equipment.
POWER ON/OFF button. The display panel will illuminate.
POWER ON/OFF button again to supply battery power to the connected
Smart-UPS On-Line SRC1KI/2KI, SRC1KI-AR/2KI-AR
9
Page 10
Install PowerChute™ Software
To install PowerChute Business Edition (PCBE) software, connect the supplied serial cable to the serial port on the UPS and the other end to a computer with access to the Web.
On the computer, go to www.apc.com/tools/download. Select “Software
Upgrades - PowerChute Business Edition” in the “Filter by Software/ Firmware” drop down menu. Select the appropriate operating system. Follow
directions to download the software.

Operation

Front display panel features
su0817b
UPS
ON/OFF button
POWER
Press the Press and hold the
POWER ON/OFF button to turn the UPS on.
POWER ON/OFF button until a beep is heard to turn
the UPS off. Press the
Status LED The Status LED illuminates green when the power is on. The LED
indicates two different states of output power:
POWER ON/OFF button to reset alerts.
Output off: LED blinks on and off. Press
POWER ON/OFF button to
turn the output power on.
Output on: LED illuminates green continuously.
LCD Display The display interface options are visible on this LCD screen. Press
UP/DOWN ARROW button to activate LCD, if the display is not
illuminated.
Smart-UPS On-Line SRC1KI/2KI, SRC1KI-AR/2KI-AR10
Page 11
MUTE/ESC
t
X
button
E
NTER button Press the ENTER button to enter the menu or to select a menu item/
UP/DOWN
ARROW button
Alert LED The Alert LED illuminates red when the UPS detects an error and
Press the MUTE/ESC button:
• To acknowledge audible alerts and suppress them temporarily.
To exit a sub menu and return to the main menu.
value during navigation.
Press the options and display screens.
blinks red for UPS notifications. See “Alerts and Notifications” on
UP/DOWN ARROW button to scroll through the main menu
page 20 in this manual.
Front display icons
On Line: The UPS is drawing utility power and performing double conversion to supply power to the connected equipment.
On Battery: The UPS is supplying battery backup power to the connected equipment.
ON BATT
Replace Battery: The battery is not connected securely or the battery is nearing the end of its service life and should be replaced.
Bypass: The UPS is in bypass mode, sending utility power directly to connected equipment. Bypass mode operation is the result of an internal UPS event or an overload condition. Battery operation is not available while the UPS is in bypass mode. See “Alerts and Notifications” on page 20 in this manual. This icon in combination with Green Mode icon, indicates that the UPS is in green mode operation.
System Alerts: An internal fault is detected. See “Alerts and
Faul
Notifications” on page 20 in this manual.
Overload: The equipment connected to the UPS is drawing more power than rated.
Battery Charge: The battery charge level is indicated by the number of bar sections illuminated. When all five blocks are illuminated, the battery is fully charged. Each bar represents approximately 20% of the battery charge capacity.
Load Level: The load percentage is indicated by the number of load bar sections illuminated. Each bar represents approximately 20% of the maximum load capacity.
Mute: An illuminated line through the icon indicates that the audible alert is disabled.
Smart-UPS On-Line SRC1KI/2KI, SRC1KI-AR/2KI-AR
11
Page 12
Green Mode: An illuminated icon indicates that the unit is working in Green mode. The connected equipment is receiving the utility input directly as long as the input voltage and frequency are within the configured limits.
Alert or notification: The UPS has detected an error or the UPS is in configuration mode. See “Alerts and Notifications” on page 20 in this manual.
EVENT
Event: The icon is illuminated when the user is viewing the event log.
LOG

Status Indicators

Audible Alert Condition
Continuous beeps, every half second Low Battery State - The battery is nearing its
complete discharge state. The UPS is about to shutdown.
Overload condition - The equipment connected to the UPS is drawing more power than rated.
4 beeps every 30 sec (first beep starts after 4 sec on battery)
Beeper continuously on Alert State - UPS has detected an error. See
Short beep every 2.5 sec Battery disconnected
Continuous short beeps for every half second for 1 minute, repeats every 5 hours
Two short beeps every 5 sec Event Bypass State - UPS has detected an error.
On Battery State - The UPS is supplying battery backup power to the connected equipment.
“Alerts and Notifications” on page 20 in this manual.
Bad battery (replace)
Connected equipment receives utility input power through the bypass relay.

UPS Display Parameters

Operational data displayed in the display panel is given in the table. Navigate using the
Output voltage Vac OUT, V
Output frequency Hz OUT, Hz
Input voltage Vac I N, V
UP/DOWN ARROW buttons.
Parameter Units Indicator Icons
Smart-UPS On-Line SRC1KI/2KI, SRC1KI-AR/2KI-AR12
Page 13
Parameter Units Indicator Icons
Input frequency Hz IN, Hz
Battery voltage V DC BAT, V
Ambient temperature ° C NUMBER, C
State of battery charge %BAT, %
Load level in percentage (Maximum of Watts or VA)
Load level in kVA kVA OUT, kVA
Total Ah capacity of connected battery Ah BAT, Ah
Remaining On Battery runtime Minutes BAT, Min
% OUT, %

Configuration

UPS settings
Configure UPS settings using the display interface. See “Configure UPS parameters” on page 16 to edit the parameters.
Function
Output voltage 230 Vac 220, 230,
Audible alert Enable Enable; disable UPS will mute audible alerts when set to
Bypass voltage ­Lower limit
Factory
Default
160 V 156 V, 160 V,
User Selectable
Options Description
Allows the user to select output voltage
240 Vac
164 V, 168 V, 172 V, 176 V, 180 V, 184 V, 188 V,
while the UPS is operating online.
disable or when the display panel button is pressed.
Allows the user to select voltage below which unit will not transfer to bypass, instead it will drop the load by turning output off. If unit is already in bypass, it will disconnect the bypass and drop the load.
MUTE
Bypass voltage ­Upper limit
Smart-UPS On-Line SRC1KI/2KI, SRC1KI-AR/2KI-AR
265 V 253 V, 257 V,
261 V, 265 V
Allows the user to select voltage above which the UPS will not transfer to bypass, instead it will drop the load by turning output off. If unit is already in bypass, it will disconnect the bypass and drop the load.
13
Page 14
Function
Factory
Default
User Selectable
Options Description
Green mode/ high efficiency mode
Minimum battery capacity to restart setting
Low battery state indication setting
Disabled Enable/Disable When this mode is enabled, connected
equipment receives utility input power through the bypass relay as long as input voltage is within the range of ± 24 V of configured output voltage and ± 3 Hz of configured output frequency. Inverter is turned off during this mode. If utility power input goes out of range, inverter is turned on. The load is transferred to online mode. The power to the connected equipment may be interrupted up to 10 milliseconds.
0% 0%, 15%, 30%,
45%, 60%, 75%, 90%,
UPS output will not be turned on until the battery is charged to a level such that it can provide the runtime configured by this setting. If configured to 0%, UPS output is turned on immediately after utility power returns.
2 min 2 min, 5 min,
8min, 11 min, 14 min, 17 min, 20 min, 23 min.
The UPS will emit audible alarm when the actual run time reaches the limit set by the end user. The audible alarm will emit only when the UPS is working in battery mode.
Advance display navigation
The UPS display has five main menu and two sub-menu options. Press the
ENTER button from the Home Screen to access these menu options. Use the UP/ DOWN ARROW buttons to navigate between the menu options.
Menu option Description
Show Event Log
Use this menu option to see the UPS event log. The UPS records the last 10 events and displays the codes in this log. Press the the logged events. The the Every log entry has a numeric and textual event code. At the end of the log, the word “End” will be displayed. Press the
Smart-UPS On-Line SRC1KI/2KI, SRC1KI-AR/2KI-AR14
ENTER button to see the log. Use the UP/DOWN ARROW buttons to see
UP ARROW button navigates towards old events and
DOWN ARROW button navigates to new events.
ESC button to return to the Home Screen.
Page 15
Menu option Description
Configure the UPS
Use this menu option to configure the UPS parameters. Press the ENTER button to see the configuration options. See “Configure UPS parameters” on page 16 for details. Press the
ESC button to return to the Home Screen.
Show UPS information
Use this menu option to see the UPS information. Press the Press the Press the
ENTER button to see the rating of the UPS. UP ARROW button to see the UPS firmware version. ESC button to return to the Home Screen.
User Command to bypass
Use this menu option to switch the UPS to bypass mode or bring the UPS to online mode from bypass mode. Press ENTER button:
Put: Use to switch the UPS to bypass mode of operation. Note: Power to the connected equipment will drop, if the mains
voltage is not within the threshold limits.
Out: Bring the UPS out of bypass and restore clean power to the connected equipment.
Execute Battery Self Test
Use this menu option to conduct a self test and determine the battery status. Press the
ENTER button to initiate the test.
If the test command is accepted, the UPS will initiate a self test and will start a count down on the display. Display messages are shown at the end of the test.
Test refused. The output is off or battery is not charged.
Test not passed
Test passed
Test is aborted due to internal reasons
Press the
ESC button to return to the Home Screen.
Smart-UPS On-Line SRC1KI/2KI, SRC1KI-AR/2KI-AR
15
Page 16
Configure UPS parameters
3
Follow the steps to configure parameters in the UPS:
1. Press the
2. Press the
3. Press the
4. Navigate through the parameters using the
5. Press the
ENTER button.
UP/DOWN ARROW buttons to navigate to “Set”.
ENTER button.
UP/DOWN ARROW buttons.
ENTER button to edit a parameter. Icons start flashing to indicate
the editing.
6. Press the
UP/DOWN ARROW buttons to navigate between the options
available for the selected parameter.
7. Press the
ENTER button to select the option or MUTE/ESC button to abort
the editing of current parameter. Flashing of icons stops after this.
8. Press the
9. Press the
UP/DOWN ARROW buttons to navigate between parameters.
MUTE/ESC button to exit menu navigation.

Emergency Power Off

The Emergency Power Off (EPO) option is a feature that will immediately remove power to all connected equipment. When EPO button is pushed, all connected equipment will immediately turn off and will not switch to battery power.
Adhere to all national and local electrical codes. Wiring must be performed by a qualified electrician.
The EPO switch is internally powered by the UPS for use with non-powered switches or potential free contacts.
Normally open (N/O) contacts
1. Retain the metal link between pins 1 and 2.
2. Remove the EPO connector screws beneath pins 2 and 3.
3. Connect N/O relay contacts between pins 2 and 3 of the EPO terminal block. Use 0.5 to 1 mm
2
wire.
4. Secure the EPO connector screws beneath pins 2 and 3.
If the N/O is closed, the UPS will turn off and power will be removed from the load.
Smart-UPS On-Line SRC1KI/2KI, SRC1KI-AR/2KI-AR16
1
Page 17
Normally closed (N/C) contacts
3
1. Remove the EPO connector screws beneath pins 1 and 2.
2. Remove the metal link between pins 1 and 2.
3. Connect N/C relay contacts between pins 1 and 2 of the EPO terminal block. Use 0.5 to 1 mm
2
wire.
1
4. Secure the EPO connector screws beneath pins 1 and 2.
5. Connect all pin 3 of all the EPO units together to: – apply EPO function of multiple units – turn off multiple units at the same time, using the EPO function
If the N/C is open, the UPS will turn off and power will be removed from the load.
NOTICE
EQUIPMENT DAMAGE
Do not connect the EPO interface to any circuit other than a unused circuit.
Failure to follow these instructions can result in equipment damage.
The EPO interface is a Safety Extra Low Voltage (SELV) circuit. Connect it only to other SELV circuits. The EPO interface monitors circuits that have no determined voltage potential. Such closure circuits may be provided by a switch or relay properly isolated from the utility. To avoid damage to the UPS, do not connect the EPO interface to any circuit other than a unused circuit.
Use one of the following cable types to connect the UPS to the EPO switch.
• CL2: Class 2 cable for general use.
• CL2P: Plenum cable for use in ducts, plenums, and other spaces used for environmental air.
• CL2R: Riser cable for use in a vertical run in a floor-to-floor shaft.
• CLEX: Limited use cable for use in dwellings and for use in raceways.
Smart-UPS On-Line SRC1KI/2KI, SRC1KI-AR/2KI-AR
17
Page 18

Troubleshooting

See “Rear Panel Features” on page 8 and “Front display panel features” on page 10 for the locations and graphical representations of the buttons and LEDs referred to in this table.
Problem and/or Possible Cause Solution
UPS will not turn on when utility input is available or there is no power output
The UPS is not turned on. Press the P
The UPS is not connected to utility power supply.
Input thermal circuit breaker on the UPS is tripped.
The UPS is operating on battery, while connected to the input utility power
There is high, low, or distorted input voltage or frequency.
UPS, when connected to battery, is not supplying power to the connected equipment
The UPS is not turned on. If the UPS has shutdown (the display is not on), follow the
The battery is not connected. Connect battery to the UPS. See “Start Up” on page 9 in
Low battery cut off. UPS may have discharged the battery due to utility power outage and turned the output off due to low battery condition.
Check that the power cable from the UPS to the utility power supply is securely connected at both ends. See “Start Up” on page 9 in this manual.
Press the input thermal circuit breaker reset button in the rear panel.
Connect the UPS to a different outlet on a different circuit. Test the utility input power to ensure the unit is receiving input power. If display is on, navigate and check the input voltage and frequency.
procedure “Cold start the UPS” on page 9.
this manual.
Wait for the utility power to return and charge the battery. To turn on the output power after utility power returns, press
OWER button to turn on the UPS.
POWER ON button.
UPS emits an audible beeping sound at long intervals
The UPS is operating normally when running on battery.
Alert LED is illuminated. The UPS displays an alert message and emits a constant beeping sound
The UPS has detected an error. See “Alerts and Notifications” on page 20 in this manual.
Smart-UPS On-Line SRC1KI/2KI, SRC1KI-AR/2KI-AR18
UPS has detected an error. See “Alerts and Notifications” on page 20 in this manual.
Page 19
Problem and/or Possible Cause Solution
No audible sounds from UPS even when the Alert LED is illuminated
Audible alert is disabled. Change the UPS configuration to enable audible alerts.
UPS is not providing expected backup time
The UPS battery is discharged due to a recent power outage.
The batteries require recharging after extended outages. Batteries can wear faster when put into service without proper recharging or when operated at elevated temperatures.
The battery is near the end of its service life.
If the battery is near the end of its service life, consider replacing the battery, even if the replace battery indicator is not illuminated. See “Start Up” on page 9 in this manual.
UPS is not turning off
POWER OFF button not pressed
properly.
Press and hold the POWER OFF button until the beep is heard to power off the UPS.
Utility input power is available. UPS logic power can not be turned off if utility input
power is available. To turn off the UPS, turn off utility input power and press
POWER OFF button. Release when a
beep is heard.
UPS is in Bypass mode and the LED is illuminated red
The UPS has experienced an overload condition and transferred to bypass.
Connected equipment exceeds the “maximum load” as defined in specifications on the APC Web site, www.apc.com. The alerts remain on until the overload condition is corrected. Disconnect nonessential equipment from the UPS to eliminate the overload condition. The UPS continues to supply power as long as it is in bypass mode and the circuit breaker does not trip. The UPS will not provide battery power in the event of a utility voltage interruption.
UPS detected an error and transferred to bypass.
Smart-UPS On-Line SRC1KI/2KI, SRC1KI-AR/2KI-AR
See “Alerts and Notifications” on page 20 in this manual.
19
Page 20
Problem and/or Possible Cause Solution
UPS is in Bypass mode and the LED is not illuminated red
UPS is in green mode Disable green mode if not desired.
UPS is configured to stay in the bypass mode.
UPS is in bypass mode even after over temperature alert is cleared.
Change the configuration to exit bypass mode.
Reduce the connected load to <90% to bring the UPS to online mode.

Alerts and Notifications

UPS displays a text code and a numeric code on the display when it detects an error.
Alerts
Display
code Description Solution
UPS has experienced a short circuit at the output.
UPS is experiencing an overload condition.
The UPS has detected a DC voltage error. Unit will try to auto-recover from this condition.
Check if there is any short circuit at the UPS output. Press
POWER ON/OFF button to start the UPS.
Note: The power supplied to the connected equipment is dropped when the UPS is in this condition.
Disconnect nonessential equipment from the UPS to eliminate the overload condition.
If the UPS does not recover automatically, contact APC by Schneider Electric.
Temperature of the unit is rising above the set limits.
UPS has recovered from an EPO shutdown.
UPS has detected a charger error.
Contact APC by Schneider Electric for all other alert codes.
Smart-UPS On-Line SRC1KI/2KI, SRC1KI-AR/2KI-AR20
Disconnect nonessential equipment from the UPS to reduce the UPS load. Ensure that ambient temperature is within limits. Ensure that adequate clearance is maintained.
Press the message.
Verify if there is any short circuit at the UPS battery terminal. Press
POWER ON/OFF button to clear the EPO
POWER ON/OFF button to start the UPS.
Page 21
Notifications
Display code Description Solution
Battery is not connected.
Connect battery to the UPS. See “Start Up” on page 9 in this manual.

Transport

1. Shut down and disconnect all connected equipment.
2. Disconnect the unit from mains power.
3. Disconnect all internal and external batteries (if applicable).
4. Follow the shipping instructions outlined in the Service section of this manual.

Service

If the unit requires service, do not return it to the dealer. Follow these steps:
Review the Troubleshooting section of the manual to eliminate common
1.
problems.
2. If the problem persists, contact APC by Schneider Electric Customer
Support through the APC by Schneider Electric web site, www.apc.com.
a. Note the model number and serial number and the date of purchase. The
model and serial numbers are located on the rear panel of the unit and are available through the LCD display on select models.
b. Call Customer Support. A technician will attempt to solve the problem
over the phone. If this is not possible, the technician will issue a Returned Material Authorization Number (RMA#).
c. If the unit is under warranty, the repairs are free.
d. Service procedures and returns may vary internationally. For country
specific instructions refer to the APC by Schneider Electric web site, www.apc.com.
3. Pack the unit properly to avoid damage in transit. Never use foam beads for
packaging. Damage sustained in transit is not covered under warranty.
Note: Before shipping, always disconnect battery modules in a UPS or external battery pack.
The disconnected internal batteries may remain inside the UPS or external battery pack.
4. Write the RMA# provided by Customer Support on the outside of the
package.
5. Return the unit by insured, prepaid carrier to the address provided by
Customer Support.
Smart-UPS On-Line SRC1KI/2KI, SRC1KI-AR/2KI-AR
21
Page 22

Limited Factory Warranty

Schneider Electric IT Corporation (SEIT), warrants its products to be free from defects in materials and workmanship for a period of two (2) years from the date of purchase. The SEIT obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. Repair or replacement of a defective product or part thereof does not extend the original warranty period.
This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase. Products may be registered online at warranty.apc.com.
SEIT shall not be liable under the warranty if its testing and examination disclose that the alleged defect in the product does not exist or was caused by end user or any third person misuse, negligence, improper installation, testing, operation or use of the product contrary to SEIT recommendations of specifications. Further, SEIT shall not be liable for defects resulting from: 1) unauthorized attempts to repair or modify the product, 2) incorrect or inadequate electrical voltage or connection, 3) inappropriate on site operation conditions, 4) Acts of God, 5) exposure to the elements, or 6) theft. In no event shall SEIT have any liability under this warranty for any product where the serial number has been altered, defaced, or removed.
EXCEPT AS SET FORTH ABOVE, THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, BY OPERATION OF LAW OR OTHERWISE, APPLICABLE TO PRODUCTS SOLD, SERVICED OR FURNISHED UNDER THIS AGREEMENT OR IN CONNECTION HEREWITH.
SEIT DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY, SATISFACTION AND FITNESS FOR A PARTICULAR PURPOSE.
SEIT EXPRESS WARRANTIES WILL NOT BE ENLARGED, DIMINISHED, OR AFFECTED BY AND NO OBLIGATION OR LIABILITY WILL ARISE OUT OF, SEIT RENDERING OF TECHNICAL OR OTHER ADVICE OR SERVICE IN CONNECTION WITH THE PRODUCTS.
THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES. THE WARRANTIES SET FORTH ABOVE CONSTITUTE SEIT’S SOLE LIABILITY AND PURCHASER EXCLUSIVE REMEDY FOR ANY BREACH OF SUCH WARRANTIES. SEIT WARRANTIES EXTEND ONLY TO ORIGINAL PURCHASER AND ARE NOT EXTENDED TO ANY THIRD PARTIES.
Smart-UPS On-Line SRC1KI/2KI, SRC1KI-AR/2KI-AR22
Page 23
IN NO EVENT SHALL SEIT, ITS OFFICERS, DIRECTORS, AFFILIATES OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT, SPECIAL, CONSEQUENTIAL OR PUNITIVE DAMAGES, ARISING OUT OF THE USE, SERVICE OR INSTALLATION OF THE PRODUCTS, WHETHER SUCH DAMAGES ARISE IN CONTRACT OR TORT, IRRESPECTIVE OF FAULT, NEGLIGENCE OR STRICT LIABILITY OR WHETHER SEIT HAS BEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES. SPECIFICALLY, SEIT IS NOT LIABLE FOR ANY COSTS, SUCH AS LOST PROFITS OR REVENUE, WHETHER DIRECT OR INDIRECT, LOSS OF EQUIPMENT, LOSS OF USE OF EQUIPMENT, LOSS OF SOFTWARE, LOSS OF DATA, COSTS OF SUBSTITUANTS, CLAIMS BY THIRD PARTIES, OR OTHERWISE.
NOTHING IN THIS LIMITED WARRANTY SHALL SEEK TO EXCLUDE OR LIMIT SEIT LIABILITY FOR DEATH OR PERSONAL INJURY RESULTING FROM ITS NEGLIGENCE OR ITS FRAUDULENT MISREPRESENTATION OF TO THE EXTENT THAT IT CANNOT BE EXCLUDED OR LIMITED BY APPLICABLE LAW.
To obtain service under warranty you must obtain a Returned Material Authorization (RMA) number from customer support. Customers with warranty claims issues may access the SEIT worldwide customer support network through the APC by Schneider Electric web site: www.apc.com. Select your country from the country selection drop down menu. Open the Support tab at the top of the web page to obtain information for customer support in your region. Products must be returned with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase.
Smart-UPS On-Line SRC1KI/2KI, SRC1KI-AR/2KI-AR
23
Page 24

APC by Schneider Electric Worldwide Customer Support

Customer support for this or any other APC by Schneider Electric product is available at no charge in any of the following ways:
• Visit the APC by Schneider Electric web site to access documents in the APC by Schneider Electric Knowledge Base and to submit customer support requests.
www.apc.com (Corporate Headquarters)
Connect to localized APC by Schneider Electric web sites for specific countries, each of which provides customer support information.
www.apc.com/support/
Global support searching APC by Schneider Electric Knowledge Base and using e-support.
• Contact the APC by Schneider Electric Customer Support Center by telephone or e-mail.
– Local, country specific centers: go to www.apc.com/support/contact
for contact information.
For information on how to obtain local customer support, contact the APC by Schneider Electric representative or other distributor from whom you purchased your APC by Schneider Electric product.
© 2016 APC by Schneider Electric. APC, the APC logo, and Smart-UPS are owned by Schneider Electric Industries S.A.S., or their affiliated companies. All other trademarks are property of their respective owners.
EN 990-9938B
11/2016
Loading...