APC LE600 Owners Manual

Page 1
Thank you for purchasing APC’s Line-R Automatic Voltage Regulator! Please fill out and
Line-R
Automatic Voltage Regulator Models LE600 and LE1200
Lights when input voltage is high.
Flashes when input voltage is above rated Input Voltage Range.
Input voltage is normal.
Lights when input voltage is low.
Flashes when input voltage is below rated Input Voltage Range.
ON/OFF Power Switch/Circuit Breaker applies and removes power to/from the Line-R. This switch also functions as a circuit breaker in the event of an over-load condition.
ON/OFF
Power Switch/
Circuit Breaker
AC Outlets (4)
(connect equipment here)
Transformer
Block AC
Outlet
AC Plug
(to wall outlet)
Building Wiring
Fault Indicator
(see Plug the
Line-R into Wall
Outlet)
User Selectable Voltage Switch
(see Select Input Voltage)
2.5 cm
(1 inch)
mail the product warranty registration form, or fill out an online form at www.apc.com.
The Line-R automatically corrects brownouts (by boosting low voltage) and overvoltages (by stepping down high voltage) from the power utility service to levels that are safe for computers, as well as other sensitive equipment. APC’s Line-R provides the highest degree of protection from line voltage sags and swells, and has been designed for many years of reliable, maintenance-free service.
Applications
The Line-R is designed for use with voltage sensitive equipment such as a: computer, monitor, inkjet printer, scanner or fax. It is also designed for use with home electronics (TVs, stereos, CD players, etc.).
Appliances not suitable for use with the Line-R are items such as refrigerators, freezers, power tools, air conditioners, dehumidifiers, blenders, or any device that employs an AC motor for operation. Not for use with life sustaining equipment and any device with a power requirement exceeding the “Maximum Output Power Capacity” rating listed in the Specifications table.
Features
ON/OFF Power Switch/Circuit Breaker
The Line-R provides an ON/OFF power switch/circuit breaker which functions as the master power switch for the Line-R and all devices connected to the device. It also functions as a circuit breaker to protect the unit from being overloaded. If the circuit breaker “trips”, unplug the last device connected to the unit, turn the power switch/circuit breaker to the OFF position, place the power switch/circuit breaker to the ON position.
Installation
• Placement - Please install the Line-R in a protected environment free of excessive dust,
mechanical vibration, inflammable gases and explosive or corrosive atmospheres.
Do not block the top or side air vents on the unit. Allow 1 inch (2.5 cm) minimum vent clearance.
• Select Input Voltage - The Line-R provides a three-position User Selectable Voltage
Switch for adjusting the input voltage for the region where it is being used (example: Mexico
- 127V, United States - 120V, or Jamaica - 110V). Slide the switch to select the proper voltage for your location.
• Plug the Line-R into Wall Outlet - Plug the Line-R into a grounded AC wall outlet. If the
Building Wiring Fault Indicator is lit, the building wiring presents a potential shock hazard and should be serviced by a qualified electrician before putting this device into service. The Line-R should only be used in buildings having proper grounding, with conductors protected by fuses or circuit breakers.
• Connect Your Equipment - Plug equipment into the Line-R rear-panel outlets and switch
the equipment ON. The equipment will not be powered until the Line-R is switched ON.
CAUTION: The total power consumption of all equipment plugged into the Line-R must not
exceed the ratings listed in the Specifications table below. A total load in excess of the listed ratings will cause the ON/OFF power switch/circuit breaker to “trip”.
• Switch ON the Line-R - Press the front panel ON/OFF power switch/circuit breaker to the ON (l) position. This switch may be used as the master ON/OFF switch for the device and all equipment connected to the unit.
Specifications
Characteristics Model LE600 Model LE1200
Maximum Output Power Capacity
Nominal Output Voltage 110, 120, or 127 (User Selectable)
Nominal Input Current 5 A 10 A
Input Voltage Range 80 - 130V (Selector Switch set to 110V)
Maximum Input Voltage 250V
Surge Energy 702 Joules
Output Regulation +6 to -12%
Response Time < 2 AC Cycles
Efficiency >93%
Nominal Frequency 50/60 Hz
Number of Outlets 4
Operating Temperature 32 - 104°F (0 - 40°C)
Relative Humidity 0 - 95% Non-condensing
Dimensions 4.6 x 8.4 x 5.5 inches (118 x 214 x 141 mm)
Weight 7.25 lb (3.3 kg) 9.7 lb (4.4 kg)
600 W or 600 VA 1200 W or 1200 VA
85 - 140V (Selector Switch set to 120V)
90 - 150V (Selector Switch set to 127V)
Limited Warranty
Schneider Electric IT (SEIT) warrants its products to be free from defects in materials and workmanship under normal use and service for the lifetime of the original purchaser. Its obligation under this warranty is limited to repairing or replacing, at its sole option, any such defective products. To obtain service under warranty you must obtain a Returned Material Authorization (RMA) number from SEIT or an SEIT Service Center with transportation charges prepaid and must be accompanied by a brief description of the problem and proof of date and place of purchase. This warranty applies only to the original purchaser.
APC by Schneider Electric IT Customer Support Worldwide
For country specific customer support, go to the APC by Schneider Electric Web site, www.apc.com.
© 2014 APC by Schneider Electric. APC, the APC logo, SurgeArrest and Line-R are owned by Schneider
Electric Industries S.A.S., or their affiliated companies. All other trademarks are property of their respective
owners.
EN 990-1286C
07/2014
Loading...