For safety, the Back-UPS ES is shipped with one battery wire disconnected. The UPS will not operate until the wire is connected to the touch-safe
battery terminal. NOTE: Small sparks may occur during battery connection. This is normal.
Turn the Back-UPS ES over and press in the
123
release tab. Slide the plastic battery cover
off of the Back-UPS.
Connect
Equipment
Connect the battery wire firmly to the
battery terminal.
Place the Back-UPS ES to avoid:
- Direct sunlight
- Excessive heat
- Excessive humidity or contact with fluids
Battery Back-up +Surge Protection
These outlets are powered whenever the Back-UPS ES is
switched ON. During a power outage or other utility problems
(brownouts, over-voltages), these outlets will be powered for a
limited time by the Back-UPS ES. Plug your computer,
monitor, and other peripheral devices into these outlets.
Plug the Back-UPS ES power cord directly into a wall outlet; not into a surge
protector or power strip.
Connect Modem / Phone / DSL / Fax
The Back-UPS protects a single line (2-wire) phone (including Digital Subscriber Line DSL), Home Phoneline Networking Association (HPNA) type equipment, modem, or fax
machines from surges when connected through the UPS as shown in the drawing below.
Insert the battery back into the compartment.
Slide the plastic battery cover until the release
tab locks into place.
Surge Protection
These outlets provide full-time protection from surges even if the
Back-UPS ES is switched OFF. Plug your printer, fax machine,
scanner, or other peripherals that do not need battery power into
these outlets.
Turn on the Unit
Press the ON/OFF switch to turn on the unit.
3
A single short beep and the green “Power On” indicator
confirms the Back-UPS ES is on and ready to provide
protection.
The Back-UPS ES should charge for at least 16 hours to
ensure sufficient runtime. The unit is being charged whenever
it is connected to utility power, whether the unit is turned ON
or OFF.
If the red Building Wiring Fault indicator (located on the end
near the power cord) is lit, your building wiring presents a
shock hazard that should be corrected by a qualified
electrician.
Transfer Voltage and
Sensitivity Adjustment
4
(Optional)
In situations where the Back-UPS, or connected equipment, is too
sensitive to the input voltage, it may be necessary to adjust the
transfer voltage. To adjust the transfer voltage:
1. Plug the Back-UPS into the utility power source. The Backwill be in “Standby mode” (no indicators are lit).
2. Press the ON/OFF push button fully in for 10 seconds. The
Online LED will begin glowing in a cyclical order: GREENAMBER-RED, indicating it is going into “Program mode”.
3. The Back-UPS will then indicate the current
sensitivity, as shown in the Transfer Voltage and Sensitivity Adjustment table below.
4. To select the LOW sensitivity setting, press the ON/OFF
push button until the LED begins
flashing GREEN.
5. To select the MEDIUM sensitivity setting, press the ON/
OFF push button until the LED begins flashing RED.
6. To select the HIGH sensitivity setting, press the ON/OFF
push button until the LED begins
flashing AMBER.
7. To exit Programming mode, once sensitivity is set, wait
approximately 5 seconds, and all of the LED indicators will
be off (unlit).
Status Indicators
The Back-UPS ES indicates operating status using a combination of visual and audible
indicators. Use the following table to identify the status of the Back-UPS ES.
On Battery - UPS is
supplying battery power to
the load connected to the
Battery outlets.
Low Battery Warning UPS is supplying battery
power to the load
connected to the battery
outlets, and the battery is
near exhaustion.
Replace Battery - The
battery is disconnected.
The battery is in need of
charging, or is at the end of
its usual life and must be
replaced.
Overload Shutdown During On Battery
operation a battery power
supplied outlet overload
was detected.
Sleep Mode - During On
Battery operation the
battery power has been
completely exhausted and
the UPS is waiting for utility
power to return to normal.
Building Wiring Fault Your building wiring
presents a shock hazard
that should be corrected by
a licensed electrician.
Indicators
Flashing
Green
Flashing
Red FlashingMEDIUM
Amber
Flashing
Sensitivity Setting
(factory default)
Power On pushbutton
- ON (lit)
Power On pushbutton
- ON (off during beep)
Power On indicator is
flashing
Replace Battery
indicator is Flashing
Power On and Replace
Battery indicators -
flashing (alternating)
NoneConstant toneUPS is turned off with the
NoneBeeping once every 4
Building Wiring Fault
LED (red) - ON
Input Voltage Range
(For Utility Operation)
LOW88-142Input voltage is extremely low or
HIGH96-136Connected equipment is
NoneNot applicable.
Beeping 4 times every
30 seconds
Rapid beeping (every
1/2 second)
Constant tone
Constant tone
seconds
NoneUPS is unplugged, or UPS
92-139Back-UPS frequently goes on
UPS transfers back to
Power On operation, or
when UPS is turned off.
UPS transfers back to
normal operation, or when
UPS is turned off.
UPS is turned off with the
power switch.
power switch.
Utility power is restored, or
if utility power is not
restored within 32 seconds,
or the UPS is turned off.
is plugged into a properly
wired outlet.
When to Use
high.
Not recommended for computer
loads.
battery.
sensitive to voltage
fluctuations.
Troubleshooting
ProblemProbable CauseSolution
Back-UPS ES will not turn
on.
The battery is disconnected, and either power is
unavailable at the wall outlet, or utility power is
having a “brownout” or an “over voltage”
Connect the battery (see Connect Battery) and ensure power is available at the wall outlet. If
battery is connected and power is unavailable, the unit can be “cold started” (operated on
battery power) by holding the power button down until two beeps are heard.
condition.
No power available at the
Surge Protection outlets.
Surge Protection outlets were overloaded.Reduce the amount of equipment plugged into the Surge Protection outlets.
Utility power not available at the wall outlet. Ensure the fuse or circuit breaker for the outlet is not tripped, and that the wall switch
controlling the outlet (if any) is in the ON position.
Back-UPS is on, but
Battery is disconnected. Connect the battery (see Connect Battery diagram).
Replace Battery indicator
flashes, and unit emits a
constant tone.
Connected equipment
loses power.
Equipment is connected to the “Surge Protection”
outlets.
The Back-UPS ES is overloaded.
PowerChute Personal Edition software has
Ensure the equipment you want to stay powered during a power failure is plugged into the
“Battery Backup plus Surge Protection” outlets and NOT the “Surge Protection Only” outlets.
Make sure the equipment plugged into the outlets of the unit are not overloading itscapacity. Try
removing some of the equipment and see if the problem continues.
The Back-UPS ES is operating normally.
performed a shutdown due to a power failure.
The Back-UPS ES has exhausted its available
battery power.
The Back-UPS ES can only operate on battery power for a limited amount of time. The unit
will eventually turn off when the available battery power has been used. Allow the unit to
recharge for 16 hours before expecting maximum runtime.
Connected equipment does not accept the stepapproximated sine waveform from the Back-UPS
The output waveform is designed for computers and computer-related equipment. It is not
designed for use with motor-type equipment.
ES.
The Back-UPS ES may require service.Contact APC Technical Support for further troubleshooting.
The Power On indicator is
lit and the Back-UPS ES
beeps four times every 30
The Back-UPS ES is On Battery.The Back-UPS ES is operating normally, and using battery power. Once On Battery, you may
want to save your current work, power down your equipment, and turn the unit OFF. Once
normal power is restored, you may turn the unit back ON, and power your equipment.
seconds.
The Power On indicator
flashes and the Back-UPS
beeps twice per second at
the same time.
Building Wiring Fault
indicator is lit.
Battery capacity is low (about 2 minutes of use
remaining).
Your building wiring presents a shock hazard.
Using the Back-UPS with this condition will void
The Back-UPS ES is about to shut off due to a low battery charge condition! When the unit
beeps twice every second, the battery has about 2 minutes of power remaining. Immediately
power down your computer ,and turn the unit OFF. When normal power returns, the unit will
recharge the battery.
Call a qualified electrician for service.
the warranty.
Inadequate runtime.The battery is not fully charged.Allow the unit to charge by leaving it plugged into the wall at least 16 hours.
Battery is near the end of useful life.As a battery ages, the amount of runtime available will decrease. You can replace the battery
by ordering one at www.apc.com. Batteries also age prematurely if the Back-UPS ES is
placed near excessive heat.
No phone/fax/DSL signal
from the Back-UPS.
Internet connection lost
during power outage.
Data line from the ISP or wall outlet is connected
to the wrong jack on the Back-UPS.
Make sure the data line from the wall outlet is connected to the jack labeled “Wall Outlet”.
Modem lost AC power. Plug the modem’s AC power cord into one of the “Battery Back-up Plus Surge Protection
Total Amperage (6 outlets)8 Amps (including UPS output)
Voltage - On Battery115 Vrms +
Frequency - On Battery60 Hz +
Transfer Time6 ms typical, 10 ms maximum
All other trademarks are property of their respective owners.
AC Surge ProtectionFull time, 340 joules
Phone/fax/DSL Surge
Protection
EMI/RFI FilterFull time
AC InputResettable circuit breaker
Average Life3 - 5 years depending on the number of discharge cycles
Size10.6 in (H) x 6.3 in (W) x 3.5 in (D)
Operating Temperature
Storage Temperature
Operating Relative Humidity0 to 95% non-condensing
Operating Elevation0 to 10,000 ft (0 to 3,000m)
Safety ApprovalsTUV C-US certified; UL 1778 standard per CSA
EMC ComplianceNotice: This device complies with part 68 and part 15 of
standard C22.2 No. 107.3, FCC part 68 &
the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful
interference, and (2) This device must accept any
interference received, including interference that may
cause undesired operation.
“On the bottom of this equipment is a label that contains,
among other information, the FCC registration number
and ringer equivalence number (REN) for this equipment.
If requested, this information must be provided to the
telephone company.”
8% (step-approximated sine wave)
Single line (2-wire)
and environmental temperature
(26.9 cm x 16 cm x 8.8 cm)
o
+32
F to 104oF (0oC to 40oC)
o
F to 113oF (-15oC to 45oC)
+5
FCC part 15 Class B, NOM certified
3
1 Hz
Order Replacement Battery
Replace with an APC qualified battery. Replacement batteries can be ordered from
www.apc.com (valid credit card required). The replacement battery part number for
this Back-UPS 350 is RBC 35.
Warranty
The standard warranty is 3 years from the date of purchase. APC’s standard
procedure is to replace the original unit with a factory reconditioned unit. Customers
who must have the original unit back due to assigned asset tags and set depreciation
schedules must declare such a need at first contact with APC Technical Support. APC
will ship the replacement unit once the defective unit is received by the repair
department or cross-ship upon the provision of a valid credit card number. The
customer pays for shipping to APC, and APC pays ground freight transportation costs
back to the customer.
Service
Please DO NOT RETURN Back-UPS ES to the place of purchase under any
circumstances.
1. Consult the Troubleshooting section to eliminate common problems.
2. Verify the battery is connected (see Connect Battery) and that the Circuit Breaker is
not tripped (see Troubleshooting section).
If you still have problems or questions, please contact APC via the internet or at one of
the phone numbers listed below.
3. Before contacting APC, please be sure to record the date purchased, UPS model,
and serial number (on bottom of unit).
4. Be prepared to troubleshoot the problem over the telephone with a Technical
Support Representative. If this is not successful, the representative will issue a Return
Material Authorization Number (RMA#) and a shipping address.
5. Pack the unit in its original packaging. If the original packaging is not available, ask
APC Technical Support about obtaining a new set. Pack the unit properly to avoid
damage in transit. Never use foam beads for packaging. Damage sustained in transit is
not covered under warranty (insuring the package for full value is recommended).
6. Write the RMA# on the outside of the package.
7. Return the unit by insured carrier to the address given to you by APC Technical
Support.
APC Contact Information
Online Technical Support:http://support.apc.com
http://www.apc.com/support
esupport@apcc.com
Web Site:www.apc.com
USA/Canada:1.800.800.4272
Mexico:+52.292.0253 / 52.292.0255
Brazil:+0800.12.72.1
Worldwide:+1.401.789.5735
Back-UPS
®
ES 350G
Guía de usuario
1
2
3
Conexión de la batería
Encendido de la unidad
Protección contra sobrevoltajes
Estos tomacorrientes proporcionan una protección completa
contra sobrevoltajes incluso si el Back-UPS ES se encuentra
apagado. Enchufe en estos tomacorrientes la impresora, máquina
de fax, escáner u otros periféricos que no necesiten energía de la
batería.
Energía de la batería +Protección
contra sobretensiones
Estos tomacorrientes estarán alimentados siempre que el
Back-UPS ES se encuentre encendido. Durante un corte de
energía u otros problemas relacionados con la alimentación
eléctrica (bajas de tensión, sobrevoltajes, etc.), el Back-UPS
ES proporcionará energía a los tomacorrientes durante un
tiempo limitado. Enchufe en estos tomacorrientes el ordenador,
monitor y otros periféricos.
Presione el botón de ENCENDIDO/APAGADO para
encender la unidad.
Un solo pitido corto y el indicador verde “Power On”
confirman que el Back-UPS ES se encuentra encendido y
listo para proporcionar protección.
Se deberá cargar el Back-UPS ES durante al menos 16
horas para asegurar un tiempo de funcionamiento adecuado.
La unidad realizará la carga de la batería siempre que se
encuentre enchufada a la energía eléctrica,
independientemente de si se encuentra encendida o
apagada.
Si se enciende el indicador “Building Wiring Fault” (ubicado
en el extremo que está cerca del cable de alimentación), la
edificación presenta un peligro de descarga eléctrica que
deberá ser resuelto por un electricista matriculado.
w w w
.apc.com
®
El Back-UPS ES indica el estado de funcionamiento utilizando una combinación de
indicadores visuales y sonoros. Utilice la siguiente tabla para identificar el estado del
Back-UPS ES.
EstadoIndicación visualAlarma sonora
La alarma se apaga
cuando
En línea - El UPS está
suministrando energía
eléctrica adaptada a la carga.
Indicador “Power On” –
ENCENDIDO (iluminado)
Ninguno.No corresponde.
Funcionando con la batería
- El UPS está suministrando
energía de la batería a la
cargas que se encuentra
enchufada en los
tomacorrientes de la batería.
Indicador “Power On” ENCENDIDO (apagado
durante los pitidos)
4 pitidos cada 30
segundos.
El UPS regresa al
funcionamiento con energía
eléctrica o cuando el UPS se
apaga.
Advertencia de batería baja
- El UPS está suministrando
energía de la batería a la
carga enchufada a los
tomacorrientes de la batería y
la batería está a punto de
agotarse.
Parpadeo del indicador
“Power On”.
Pitidos rápidos (cada
medio segundo).
El UPS regresa al
funcionamiento normal o
cuando el UPS se apaga.
Reemplazar batería - La
batería está desconectada.
Se debe cargar la batería o
ésta llegó al final de su vida
útil y deberá ser
reemplazada.
Parpadeo de indicador
“Replace Battery”.
Indicadores “Power On” y
“Replace Battery” parpadeando (de forma
alternada)
Tono constante.
Tono constante.
Se apagó el UPS con el
interruptor de encendido/
apagado.
Apagado por sobrecarga Durante el funcionamiento
con la batería, se detectó una
sobrecarga en un
tomacorriente al que se le
está proporcionado energía
de la batería.
Ninguno.Tono constante.Se apagó el UPS con el
interruptor de encendido/
apagado.
Modo de espera - Durante el
funcionamiento con la
batería, la carga de la batería
se agotó por completo y el
UPS está esperando que le
energía eléctrica regrese a la
normalidad.
Ninguno.Pitidos cada 4 segundos. Regrese la energía eléctrica,
cuando la energía eléctrica no
haya regresado al cabo de 32
segundos o cuando se
apague el UPS.
Falla en el cableado de la
edificación - El cableado de
la edificación presenta un
peligro de descarga eléctrica
que deberá ser resuelto por
un electricista matriculado.
Indicador LED “Building
Wiring Fault” (Falla en el
cableado de la
edificación) (rojo) ENCENDIDO.
Ninguno.Se desenchufe el UPS o
cuando se enchufe el UPS a
un tomacorriente de pared
con un cableado correcto.
Indicadores de estado
Por razones de seguridad, se envía el Back-UPS ES con un cable de la batería desconectado. La UPS no funcionará hasta que se conecte el cable al
terminal de la batería seguro al tacto. NOTA: Es posible que se produzcan algunas chispas durante la conexión de la batería. Esto es normal.
Voltee el Back-UPS ES y presione el pestillo
de liberación. Deslice hacia fuera la tapa de
plástico de compartimiento de la batería.
Coloque nuevamente la batería en el
compartimiento. Deslice la tapa de plástico del
compartimiento de la batería hasta que el
Conecte el cable de la batería de
forma firme al terminal de la batería.
123
Conexión de dispositivos
Conexión de módem / teléfono / DSL / fax
El Back-UPS ES brinda protección contra sobrevoltajes a teléfonos de una sola línea (2
alambres) (incluida la Línea de Suscripción Digital – DSL, por sus siglas en inglés),
equipos HPNA (Alianza de Redes de Líneas Telefónicas Domésticas), módems o
máquinas de fax cuando se encuentran enchufados a través del UPS como se muestra
en la ilustración que aparece abajo.
No exponga el Back-UPS ES a las siguientes condiciones:
- Luz solar directa
- Calor excesivo
- Humedad excesiva o contacto con fluidos
Enchufe el Back-UPS ES directamente en un tomacorriente de pared y no en un
protector contra sobretensiones ni múltiple.
4
Ajuste de voltaje y
sensibilidad de la
transferencia (opcional)
Cuando el Back-UPS ES o los equipos enchufados sean
demasiado sensibles al voltaje de entrada, es posible que sea
necesario ajustar el voltaje de transferencia. Para ajustar el voltaje
de transferencia:
1. Enchufe el Back-UPS ES a la fuente de energía eléctrica. El
Back-UPS ES ingresará en el “modo de espera” (no se
encenderá ningún indicador).
2. Mantenga presionado el botón de ENCENDIDO/APAGADO
durante 10 segundos. El indicador LED comenzará a
parpadear en un orden cíclico: VERDE-ÁMBAR-ROJO, lo
que indica que el Back-UPS ES ingresará en el “modo de
programación”.
3. El Back-UPS ES indicará la sensibilidad actual, como
muestra la tabla Ajuste de voltaje y sensibilidad de la transferencia que aparece más adelante.
4. Para seleccionar la configuración de sensibilidad BAJA,
presione el botón de ENCENDIDO/APAGADO hasta que el
indicador LED comience a parpadear de color VERDE.
5. Para seleccionar la configuración de sensibilidad MEDIA,
presione el botón de ENCENDIDO/APAGADO hasta que el
indicador LED comience a parpadear de color ROJO.
6. Para seleccionar la configuración de sensibilidad ALTA,
presione el botón de ENCENDIDO/APAGADO hasta que el
indicador LED comience a parpadear de color ÁMBAR.
7. Para salir de modo de programación, una vez que se haya
establecido la sensibilidad, espere aproximadamente 5
segundos y todos los indicadores LED se apagarán.
Indicadores
LED
parpadeando
de color
Configuración de
sensibilidad
Rango del voltaje de
entrada (para el
funcionamiento con
energía eléctrica)
Se recomienda utilizar esta
configuración cuando
Verde
parpadeando
BAJA88-142El voltaje de entrada es
extremadamente bajo o alto. No
recomendado para cargas
pertenecientes a computadoras.
Rojo
parpadeando
MEDIA
(configuración por
defecto de
fábrica)
92-139El Back-UPS ES funciona de
forma frecuente con la batería.
Ámbar
parpadeando
ALTA96-136Los equipos conectados son
sensibles a las fluctuaciones en
el voltaje.
Resolución de problemas
Información de contacto de APC
Soporte técnico en línea:http://support.apc.com
http://www.apc.com/support
esupport@apcc.com
Sitio Web:www.apc.com
Estados Unidos/Canadá:1.800.800.4272
México:+52.292.0253 / 52.292.0255
Brasil:+0800.12.72.1
Internacional:+1.401.789.5735
Servicio técnico
Por favor, NO DEVUELVA el Back-UPS ES al lugar de compra bajo ninguna
circunstancia.
1. Consulte la sección Resolución de problemas para descartar los problemas
comunes.
2. Verifique que la batería se encuentre conectada (consulte Conexión de la batería) y
que el disyuntor no se haya disparado (consulte la sección Resolución de problemas).
Si el problema persiste o tiene alguna duda, póngase en contacto con APC a través de
Internet o uno de los números telefónicos que aparecen abajo.
3. Antes de ponerse en contacto con APC, asegúrese de registrar la fecha de compra,
modelo del UPS y número de serie (ubicado en la parte inferior del producto).
4. Esté preparado para resolver el problema por teléfono con la ayuda de un
representante de soporte técnico. Si no se puede resolver el problema, el
representante emitirá un Número de Autorización de Devolución de Producto (RMA,
por sus siglas en inglés).
5. Empaque la unidad en su embalaje original. Si no cuenta con el embalaje original,
comuníquese con el Departamento de Soporte Técnico de APC para obtener
información acerca de cómo obtener uno nuevo. Empaque la unidad de forma
correcta para evitar daños durante el envío. Nunca utilice partículas de espuma como
material de embalaje. Los daños sufridos durante el envío no se encuentran cubiertos
por la garantía. (Se recomienda asegurar la unidad por su valor de reposición).
6. Escriba el RMA en la parte exterior del embalaje.
7. Envíe la unidad a través de una empresa transportista asegurada a la dirección
proporcionada por el Departamento de Soporte Técnico de APC.
Garantía
La garantía estándar es de 3 años desde la fecha de compra. El procedimiento
estándar de APC consiste en reemplazar la unidad original por una unidad
reacondicionada de fábrica. Los clientes que necesiten disponer de la unidad original
debido a clasificaciones de inventario asignadas y programas de depreciación de
activo deberán declarar tales condiciones cuando se comuniquen por primera vez con
el Departamento de Soporte Técnico de APC. APC enviará la unidad de reemplazo
una vez que la unidad defectuosa haya sido recibida por el departamento de
reparación o realizará un envío simultáneo contra la recepción de un número de
tarjeta de crédito válido. El cliente abonará el envío de la unidad a APC, en tanto que
APC abonará los costos de transporte por tierra a la dirección del cliente.
Cómo solicitar una batería de reemplazo
Reemplace la batería por una batería aprobada por APC. Se puede solicitar las
baterías de reemplazo desde www.apc.com (se requiere una tarjeta de crédito válida).
El número de pieza de la batería de reemplazo para este Back-UPS ES es RBC 35.
Especificaciones
Modelo BE350G
EntradaVoltaje120 Vrms nominales
Frecuencia 60 Hz ± 3
Transferencia en baja tensión 92 Vrms, normal
Transferencia en sobretensión139 Vrms, normal
SalidaCapacidad del UPS (3
tomacorrientes)
350 VA; 200 W
Amperaje total (6
tomacorrientes)
8 Amperes (incluyendo la salida del UPS)
Voltaje – Funcionamiento con la
batería
115 Vrms ± 8% (onda sinusoidal aproximada por escalones)
Frecuencia – Funcionamiento
con la batería
60 Hz ± 1 Hz
Tiempo de transferencia6 ms normal, 10 ms máximo
Protección y
filtro
Protección contra
sobretensiones de CA
Permanente, 340 julios
Protecciones contra
sobretensiones del teléfono/fax/
DSL
Línea única (2 alambres)
Filtro EMI/RFIPermanente
Entrada CADisyuntor reiniciable
BateríaTipoSellada, de plomo ácido y no requiere mantenimiento
Vida útil3 - 5 años dependiendo de la cantidad de ciclos de descarga y
temperatura ambiente
Dimensiones
físicas
Peso neto8,6 libras (3,9 kg)
Tamaño10,6 pulgadas (Alto) x 6,3 pulgadas (Ancho) x 3,5 pulgadas
(Profundidad)
(26,9 cm x 16 cm x 8,8 cm)
Temperatura de funcionamiento +32ºF a 104ºF (0ºC a 40ºC)
Temperatura de
almacenamiento
+5ºF a 113ºF (-15ºC a 45ºC)
Temperatura de funcionamiento
relativa
0 a 95% sin condensación
Altitud de funcionamiento0 a 10.000 pies (0 a 3.000 metros)
Seguridad y
avisos
regulatorios
Aprobaciones de seguridadCertificado por TUV C-US, listado por la norma UL 1778,
certificado por CSA según la norma CSA C22.2 Núm. 107,3,
certificado por la parte 68 y 15 de la FCC y certificado por la
norma NOM.
Cumplimiento de compatibilidad
electromagnética
Aviso: Este dispositivo cumple con la parte 68 y 15 de las
reglas de la FCC. El funcionamiento se encuentra sujeto a
las siguientes dos condiciones: (1) Este dispositivo no
causará interferencia dañina y (2) este dispositivo debe
aceptar cualquier interferencia recibida, incluyendo una
interferencia que podría causar un funcionamiento no
deseado.
“En la parte inferior de este equipo se encuentra una etiqueta
que contiene, entre otra información, el número de registro
de la FCC y el número de equivalencia de timbre (REN, por
sus siglas en inglés) de este equipo. Se deberá proporcionar
esta información a la compañía telefónica si es solicitada”.
El Back-UPS ES no enciende. La batería está desconectada, el tomacorriente de
No existe alimentación
eléctrica en los
tomacorrientes de
protección contra
sobretensiones.
El Back-UPS ES está
encendido, pero el indicador
“Replace Battery” parpadea y
la unidad emite un tono
constante.
Los equipos enchufados
pierden energía.
pared no proporciona energía eléctrica o la energía
eléctrica proporcionada posee una condición de “baja
tensión” o “sobretensión”.
Sobrecarga en los tomacorrientes de protección contra
sobretensiones.
El tomacorriente de pared no proporciona energía
eléctrica.
La batería está desconectada. Conecte la batería (consulte el diagrama de la sección Conexión de la batería).
Lo equipos está enchufados a los tomacorrientes de
protección contra sobretensiones.
Sobrecarga del Back-UPS ES. Asegúrese de que los equipos enchufados a estos tomacorrientes de la unidad no estén sobrecargando
Conecte la batería (consulte Conexión de la batería) y asegúrese de que el tomacorriente de pared
proporcione energía eléctrica. Si la batería se encuentra conectada y no existe energía eléctrica
disponible, se puede realizar un “encendido en frío” (utilizando la energía de la batería) presionado el
botón de encendido/apagado hasta escuchar dos pitidos.
Reduzca la cantidad de equipos enchufados en los tomacorrientes de protección contra sobrevoltajes.
Asegúrese de que no se haya disparado el fusible o disyuntor del tomacorriente de pared y que el
interruptor de pared que controla al tomacorriente de pared (si existiese alguno) se encuentre encendido.
Asegúrese de que los equipos que desea que permanezcan encendidos durante una falla en la energía
eléctrica se encuentre enchufados en los tomacorrientes “Battery Backup + Surge Protection” (Energía
de la batería + protección contra sobretensiones) y NO en los tomacorrientes de sólo “Surge Protection”
(Protección contra sobretensiones).
su capacidad. Intente extraer algunos equipos y compruebe si persiste el problema.
El indicador “Power On” se
encuentra encendido y el
Back-UPS ES emite cuatro
pitidos cada 30 segundos.
El indicador “Power On”
parpadea y el Back-UPS ES
emite al mismo tiempo 2
pitidos por segundo.
El indicador “Building Wiring
Fault” se encuentra
encendido.
Tiempo de funcionamiento
inadecuado.
No existe señal de teléfono/
fax/DSL desde el Back-UPS
ES.
Pérdida de la conexión a
Internet durante un corte de
energía.
El software PowerChute Personal Edition llevó a cabo
un proceso de apagado debido a una falla en la energía
eléctrica.
El Back-UPS ES agotó la energía de la batería
disponible.
El equipo enchufado no acepta la forma de onda
sinusoidal aproximada por escalones del Back-UPS
ES.
Es posible que el Back-UPS ES deba ser reparado. Contáctese con el Departamento de Soporte Técnico de APC para solicitar ayuda adicional acerca de la
El Back-UPS ES está funcionando con la batería.El Back-UPS ES está funcionando de forma normal y utilizando la energía de la batería. Una vez que la
Carga de la batería baja (aproximadamente 2 minutos
de uso restantes).
El cableado de la edificación presenta un peligro de
descarga. La utilización del Back-UPS ES en estas
condiciones anulará la garantía.
La batería no posee una carga completa. Espere que la unidad se cargue dejándola enchufada al tomacorriente de pared durante al menos 16
La batería se está acercando al final de su vida útil. A medida que la batería envejece, se irá reduciendo el tiempo de funcionamiento disponible. Puede
Se conectó la línea de datos del proveedor de Internet o
del conector de pared en un conector incorrecto del
Back-UPS ES.
El módem no posee alimentación CA. Enchufe el cable de alimentación CA del módem en uno de los tomacorrientes “Battery Back-up + Surge
El Back-UPS ES funciona de forma normal.
El Back-UPS ES sólo funciona con la energía de la batería durante una cantidad de tiempo limitada. La
unidad se apagará cuando se haya utilizado toda la energía de la batería disponible. Espere que la
unidad se recargue durante 16 horas para que pueda alcanzar el tiempo de funcionamiento máximo.
La forma de onda de salida se encuentra diseñada para ordenadores y equipos relacionados con los
ordenadores. No se encuentra diseñada para su utilización con equipos con motor.
resolución de problemas.
unidad esté funcionando con la batería, guarde el trabajo actual, apague los equipos y luego apague la
unidad. Una vez que haya regresado la energía eléctrica normal, encienda la unidad y luego encienda
los equipos.
¡El Back-UPS ES está a punto de apagarse debido a la poca carga de la batería! Cuando la unidad emita
dos pititos por segundo, la batería posee aproximadamente 2 minutos restantes de energía. Apague de
inmediato el ordenador y luego apague la unidad. Cuando regrese la energía eléctrica normal, la unidad
se encargará de recargar la batería.
Póngase en contacto con un electricista calificado para efectuar la reparación.
horas.
reemplazar la batería solicitando una en www.apc.com. Las baterías también envejecen prematuramente
si el Back-UPS ES se encuentra colocado cerca de una fuente de calor excesivo.
Asegúrese de que la línea de datos del proveedor del tomacorriente de pared se encuentre enchufada en
el conector “Wall Outlet” (“Salida de pared”).
Protection outlets”.
Back-UPS
®
ES 350G
Guide de l’utilisateur
1
2
3
Branchement de la batterie
l’équipement
Allumez l’appareil.
Protection contre les surtensions
Ces prises de sortie offrent une protection continue contre les
surtensions même lorsque le Back-UPS ES est éteint (« OFF »).
Branchez votre imprimante, votre fax, votre scanneur ou vos autres
appareils n’ayant pas besoin de la batterie de sauvegarde sur ces
prises.
Batterie de sauvegarde +Protection
contre les surtensions
Ces prises de sortie sont sous tension dès que le Back-UPS ES
est allumé (« ON »). Pendant une panne de courant ou en cas
d’un autre problème (baisses de tension, surtensions), ces
prises seront alimentées pendant une certaine période par le
Back-UPS ES. Branchez votre ordinateur, votre moniteur et vos
autres appareils externes sur ces prises.
Appuyez sur le bouton ON/OFF pour allumer l’appareil.
Vous entendrez un bip puis l'indicateur « Sous tension »
s'affichera, indiquant que le Back-UPS ES est allumé et prêt à
protéger les appareils.
Le Back-UPS ES doit être rechargé pendant au moins 16
heures pour un fonctionnement optimal. L’appareil se recharge
automatiquement lorsqu'il est branché sur une prise de courant
secteur, qu'il soit allumé (« ON ») ou éteint (« OFF »).
Si l’indicateur « Problème de câblage du bâtiment » (situé près
du cordon d’alimentation) s’allume, cela indique que votre
bâtiment présente un risque d’électrocution et que ce problème
doit être rectifié par un électricien qualifié.
w w w
.apc.com
®
Le Back-UPS ES indique l’état de fonctionnement à l’aide d’une combinaison
d’indicateurs visuels et sonores. Utilisez le tableau suivant pour identifier l’état du BackUPS ES.
EtatIndicateur visuelAlarme sonoreArrêt de l’alarme
Sous tension - le UPS fournit
une alimentation secteur
contrôlée aux appareils.
Bouton de mise en
marche – ALLUMÉ
(allumé)
AucunSans objet.
Avec batt eri e - le UPS fournit
une alimentation batterie aux
appareils branchés sur les
prises Batterie.
Bouton de mise en
marche – ALLUMÉ
(éteint pendant les bips)
Un bip 4 fois toutes les
30 secondes.
Le UPS retourne au mode
Sous tension, ou lorsque le
UPS est éteint.
Avertissement batterie faible
- le UPS fournit une
alimentation batterie aux
appareils branchés sur les
prises Batterie et la batterie est
presque vide.
L’indicateur Marche
clignote
Bip rapide (toutes les
demi secondes)
Le UPS retourne au mode
Sous tension, ou lorsque le
UPS est éteint.
Remplacer la batterie - La
batterie est débranchée.
La batterie a besoin d’être
chargée ou a atteint la fin de
sa durée de vie et doit être
remplacée.
L’indicateur Remplacer
la batterie clignote
Les indicateurs Marche
et Remplacer la batterie
clignotent
(alternativement)
Tonalité constante
Tonalité constante
L’UPS est éteint avec le
bouton d’alimentation.
Arrêt surcharge - En mode de
fonctionnement Avec batterie,
une des prises de sortie est
surchargée.
AucunTonalité constanteL’UPS est éteint avec le
bouton d’alimentation.
Mode Sommeil - En mode de
fonctionnement Avec batterie,
la batterie est presque vide et
l’UPS atteint que l’alimentation
secteur soit rétablie.
AucunUn bip toutes les 4
secondes
L’alimentation secteur a été
rétablie ou l’alimentation
secteur n’a pas été rétablie
en moins de 32 secondes
ou le UPS est éteint.
Problème de câblage du
bâtiment - Le câblage dans
votre bâtiment présente un
risque d’électrocution et ce
problème doit être rectifié par
un électricien qualifié.
Voyant DEL de
problème de câblage de
bâtiment (rouge) ALLUMÉ
AucunL’UPS est débranché ou
l'UPS est branché sur une
prise de courant qui marche
normalement.
Indicateurs d’état
Pour des raisons de sécurité, le Back-UPS ES est fourni avec une batterie dont l’un des fils est débranché. Le UPS ne marchera pas dans cet état ; vous
devez brancher le fil sur la borne correspondante de la batterie avant de pouvoir l’utiliser. REMARQUE : Des petites étincelles peuvent apparaître
lorsque vous branchez la batterie. Ceci est normal.
Retournez le Back-UPS ES et appuyez sur
l’onglet d’ouverture. Faites glisser le couvercle
en plastique de la batterie du Back-UPS.
Remettez la batterie dans le compartiment.
Remettez le couvercle en plastique de la
batterie pour fermer le compartiment.
Branchez fermement le fil sur la
borne de la batterie.
123
Brancher
Branchez un modem / un téléphone / une ligne d’accès numérique (DSL) / un fax
Le Back-UPS permet aussi de protéger une ligne téléphonique à 2 fils (y-compris une ligne
d’accès numérique – DSL), un appareil d’association Home-PNA (HPNA), un modem ou un
fax contre les surtensions lorsque l’appareil est branché sur le UPS comme indiqué dans le
dessins ci-dessous.
Posez le Back-UPS ES dans un endroit à l’abri :
- du soleil.
- de la chaleur excessive.
- de l’humidité excessive ou de tout contact avec des fluides.
Branchez directement le cordon d’alimentation du Back-UPS ES sur une prise de
courant, et non sur un suppresseur de surtension ou sur une rallonge électrique.
4
Réglage de la tension de
transfert et de la
sensibilité (Optionnel)
Dans certains cas où le Back-UPS, ou l’appareil connecté, est trop
sensible à la tension d’entrée, il peut être nécessaire de régler la
tension de trasnfert. Pour régler la tension de transfert :
1. Branchez le Back-UPS sur une source de courant. Le BackUPS sera en "Mode Veille" (les indicateurs sont tous
éteints).
2. Appuyez sur le bouton-poussoir ON/OFF pendant 10
secondes. Le voyant DEL en ligne s’allume et change dans
l’ordre suivant : VERT- ORANGE-ROUGE, indiquant qu’il va
en “Mode Programme”.
3. Le Back-UPS affichera ensuite
la sensibilité actuelle, comme indiquée dans le tableau
Réglage de la tension de transfert et de la sensibilité cidessous.
4. Pour sélectionner le réglage de sensibilité FAIBLE, appuyez
sur le bouton ON/OFF jusqu’à ce que le voyant DEL
clignote en VERT.
5. Pour sélectionner le réglage de sensibilité MOYENNE,
appuyez sur le bouton ON/OFF jusqu’à ce que le voyant
DEL clignote en ROUGE.
6. Pour sélectionner le réglage de sensibilité HAUTE, appuyez
sur le bouton ON/OFF jusqu’à ce que le voyant DEL
clignote en ORANGE.
7. Pour quitter le Mode Programme, une fois que la sensibilité
a été réglée, attendez environ 5 secondes ; tous les voyant
DEL s’éteindront.
Indicateurs
clignotent
Réglage de la
sensibilité
Gamme de tension
d’entrée (utilisation avec
utilitaire)
Quand les utiliser
Vert
Clignotant
FAIBLE88-142Tension d’entrée très faible ou haute.
Pas recommandé pour les charges
d’ordinateur.
Rouge
clignotant
MOYEN
(par défaut)
92-139Le Back-UPS va fréquemment à la
batterie.
Orange
clignotant
HAUT96-136L’appareil connecté est sensible aux
fluctuations de tension.
Guide de dépannage
Informations de contact de APC
Support technique en ligne:http://support.apc.com
http://www.apc.com/support
esupport@apcc.com
Site Web:www.apc.com
USA/Canada:1.800.800.4272
Mexique:+52.292.0253 / 52.292.0255
Brésil:+0800.12.72.1
Reste du monde:+1.401.789.5735
Entretien
NE PAS RETOURNER le Back-UPS ES à l’endroit où vous l’avez acheté.
1. Consultez la section Guide de dépannage pour résoudre les problèmes les plus fréquents.
2. Vérifiez que la batterie est correctement branchée (voir Branchement de la batterie) et que le
disjoncteur n’est pas déclenché (voir la section Guide de dépannage).
Si vous avez toujours des questions ou des problèmes, contactez APC via Internet ou l’un des
numéros de téléphone indiqués ci-dessous.
3. Avant de contacter APC, assurez-vous que vous avez avec vous la date d'achat, le modèle
de l'UPS et le numéro de série (situé sous l'appareil).
4. Soyez prêt à essayer de résoudre le problème par téléphone en parlant avec un représentant
du Support technique. Si le problème ne peut pas être résolu, le représentant vous donnera un
numéro RMA (numéro d’autorisation de retour de marchandise) et une adresse.
5. Emballez l’appareil, en utilisant la boîte originale. Si vous n’avez plus la boîte originale,
demandez au Support technique de APC de vous en fournir une nouvelle. Emballez
correctement l’appareil pour qu’il ne subisse aucun dommage pendant le transport. N’utilisez
jamais de la mousse pour l'emballage. Les dommages survenus pendant le transport ne seront
pas couverts par la garantie (il est recommandé de garantir le paquet pour la valeur totale).
6. Ecrivez le numéro RMA# sur le coté de la boîte.
7. Renvoyez l’appareil par une compagnie de transport avec assurance à l’adresse qui vous a
été donnée par le Support technique de APC.
Garantie
La garantie standard est pour une période de 3 ans à partir de la date d’achat de l’appareil. La
procédure standard de APC est de remplacer l’appareil original par un appareil réparé/remis à
neuf en usine. Les clients qui désirent recevoir le même appareil pour des raisons de taux de
moins-values et un plan d’amortissement doivent informer le Support technique de APC
pendant le premier contact. APC renverra l’appareil de remplacement une fois que l'appareil
défectueux a été reçu par le département des réparations ou peut l'envoyer avant de le recevoir
si vous utilisez une carte de crédit comme garantie. Le client doit payer les frais d'envoi vers
APC ; APC paiera les frais de transport pour renvoyer l'appareil au client.
Commander une batterie de
Utilisez seulement une batterie de APC. Les batteries de remplacement peuvent être
commandées sur www.apc.com (paiement par carte de crédit). Le numéro de pièce de la
batterie de remplacement pour ce Back-UPS est : RBC 35.
Caractéristiques techniques
Modèle BE350G
EntréeTension120 Vrms nominal
Fréquence 60 Hz ± 3
Transfert de baisse de tension92 Vrms, typique
Transfert de surtension139 Vrms, typique
SortieCapacité UPS (3 prises)350 VA; 200 W
Intensité totale (6 prises)8 Amps (y-compris la sortie UPS)
Tension - Avec batterie115 Vrms ± 8% (courant à ondes sinusoïdales)
Fréquence – Avec batterie60 Hz ± 1 Hz
Temps de transfert6 ms typique, 10 ms maximum
Protection et
filtre
Protection contre les
surtensions c.a.
Plein temps, 340 joules
Protection contre les
surtensions pour téléphone/
fax/DSL
Une ligne (2-fils)
Filtre EMI/RFIPlein temps
Entrée c.a.Disjoncteur réglable
BatterieTypeEtanche au plomb, sans entretien nécessaire
Durée de vie moyenne 3 à 5 ans, en fonction du nombre de cycles de
chargement/déchargement et de la température ambiante
Caractéristique
s physiques
Poids net8,6 livres (3,9 kg)
Taille10,6 pouce (H) x 6,3 pouce (L) x 3,5 pouce (D)
(26,9 cm x 16 cm x 8,8 cm)
Température d’utilisation+32ºF à 104ºF (0ºC à 40ºC)
Température de stockage+5ºF à 113ºF (-15ºC à 45ºC)
Humidité d’utilisation0 à 95% sans condensation
Altitude d’utilisation0 à 10 000 pieds (0 à 3 000m)
Normes et
régulations
Agréments de sécuritéCertifié TUV C-US ; standard UL 1778 par standard CSA
C22.2 No. 107,3, FCC partie 68 & FCC partie 15 Classe
B, certifié NOM
Conformité EMCRemarque : Cet appareil est conforme à la section 68 et
à la section 15 du règlement de la FCC. L’utilisation de
cet appareil est soumise aux deux conditions suivantes :
(1) Cet appareil ne doit pas causer d’interférences
nuisibles et (2) cet appareil doit être capable d’accepter
toutes les interférences éventuelles, y-compris les
interférences pouvant provoquer un fonctionnement
inattendu.
Sur le dessous de l’appareil, une étiquette est placée qui
stipule, entre autre, le numéro d’enregistrement FCC et
le numéro équivalent en sonnerie (REN) pour cet
appareil. Vous devez fournir, sur demande, ces
informations à votre opérateur téléphonique.
Les prises de protection
contre les surtensions ne
marchent pas.
Le Back-UPS est allumé mais
l’indicateur « Remplacer la
batterie » clignote et une
tonalité constante est émise.
Les appareils branchés
perdent de la puissance.
La batterie est débranchée et l’alimentation de la
prise de courant n’est pas disponible, ou
l’alimentation secteur a une ‘baisse de tension’ ou
une ‘surtension’.
Les prises de protection contre les surtensions sont
Branchez la batterie (voir Branchement de la batterie) et assurez-vous que la prise de courant
mural marche correctement. Si la batterie est branchée et que l'alimentation ne marche pas,
l'appareil peut être 'démarré à froid' (marche avec la batterie) en appuyant sur le bouton
d'alimentation jusqu’à ce que vous entendiez deux bips.
Réduisez le nombre d’appareils branchés sur les prises « Protection contre les surtensions ».
surchargées.
L'alimentation secteur de la prise de courant n'est
pas disponible.
Assurez-vous que le fusible ou le disjoncteur de la prise n’est pas déclenché, et que l’interrupteur
mural de la prise (s’il y en a un) est en position ON (ALLUMÉ).
La batterie est débranchée. Branchez la batterie (voir le schéma Branchement de la batterie).
L’appareil est branché sur les prises « Protection
contre les surtensions ».
Assurez-vous que l’appareil qui doit rester allumé pendant une panne de courant est branché sur
la prise « Batterie de sauvegarde plus protection contre les surtensions » au lieu des prises
« Protection contre les surtensions ».
Le Back-UPS ES est surchargé.Assurez-vous que les appareils branchés sur les prises de l’appareil ne dépassent pas sa
capacité. Essayez de débrancher des appareils pour voir si le problème continue.
L’indicateur
« Sous tension » est allumé et
le Back-UPS ES bip 4 fois
toutes les 30 secondes.
L’indicateur « Sous tension »
clignote et le Back-UPS ES bip
2 fois par secondes.
L'indicateur « Problème de
câblage de bâtiment » est
allumé.
Durée de fonctionnement
insuffisante.
Aucun signal de téléphone/
fax/DSL venant du Back-UPS.
Connexion Internet coupée
pendant une panne de
courant.
Le logiciel PowerChute Personal Edition a arrêté le
Le Back-UPS ES marche normalement.
système à cause d'une panne de courant.
La batterie du Back-UPS ES est vide.Le Back-UPS ES peut seulement marcher avec la batterie pendant une certaine période.
L'appareil s'éteindra après une certaine période, lorsque la batterie est déchargée. Laissez
l’appareil se recharger pendant 16 heures pour un fonctionnement optimal.
L’appareil connecté n’accepte pas le courant à
ondes sinusoïdales du Back-UPS ES.
Le courant à ondes sinusoïdales est conçu pour les ordinateurs et les appareils associés. Il n’est
pas conçu pour les appareils à moteur.
Le Back-UPS ES a besoin d’être réparé.Contactez le Support technique de APC pour plus d’informations de dépannage.
Le Back-UPS ES est en mode « Avec batterie ».Le Back-UPS ES marche normalement et utilise la batterie. Une fois en mode « Avec batterie »,
vous pouvez sauvegarder vos fichiers, éteindre votre ordinateur et éteindre l’appareil (« OFF »).
Une fois que le courant normal a été restauré, vous pouvez rallumer l’appareil (« ON ») et votre
ordinateur.
La capacité de la batterie est faible (seulement 2
minutes d’utilisation restantes).
Le Back-UPS ES va s’éteindre car la batterie est presque vide ! Lorsque l’appareil bip 2 fois par
secondes, il ne reste qu’environ 2 minutes de puissance. Eteignez immédiatement votre
ordinateur puis éteignez l’appareil (« OFF »). Lorsque le courant est rétabli, la batterie de
l’appareil se rechargera.
Le câblage de votre bâtiment présente un danger
Contactez un électricien qualifié pour une réparation.
d'électrocution. Si c’est le cas, l’utilisation du BackUPS ES annulera la garantie.
La batterie n’est pas complètement rechargée.Laissez l’appareil branché sur la prise pendant au moins 16 heures pour recharger la batterie.
La batterie est presque à la fin de sa durée de vie.Plus la batterie vieillie, plus la durée de fonctionnement diminue. Vous pouvez remplacer la
batterie en commandant une nouvelle sur www.apc.com. Les batteries vieillissent aussi plus
rapidement lorsque le Back-UPS ES est installé dans des endroits excessivement chauds.
La ligne de données de l’ISP ou la prise murale est
branchée sur la mauvaise prise du Back-UPS.
Assurez-vous que la ligne de données de la prise murale est branchée sur la prise « Prise murale ».
L'alimentation du modem a été coupée. Branchez le cordon d’alimentation du modem sur l’une des prises « Batterie de sauvegarde plus
protection contre les surtensions ».