A.O. Smith TJ-80S, TJ-80A, TJV-120M, TJV-200M, TJV-120A User Manual

Page 1
FACTORY JACKETED AND INSULATED STORAGE TANKS
Commercial Storage Tanks
MODELS
These A. O. Smith storage tanks are designed for storing potable water. Fitting locations are designed to meet the needs of normal installations plus those for the A. O. Smith Cer-Temp 80
FEATURES
A. O. Smith storage tanks are ideal for use with gas-fired copper heat exchanger equipment for storage of any potable water at temperatures up to 180°F.
GLASS LINED TANK - Alkaline borosilicate composition permanently fused to steel by firing at a temperature of 1600°F, providing years of corrosion
HEAVY GAUGE STEEL JACKET - With baked enamel finish.
THREADED OPENINGS - All tanks furnished with threaded openings for thermometer, relief valve, 2” recirculation lines, tankstat, and drain valve.
INSULATION - Storage Tanks meet or exceed R12.5 minimum thermal insulation requirements of the U. S. Department of Energy and current edition of ASHRAE/IESNA 90.1
TJ-80S, TJ-80A, TJV-120M and TJV-120A
protection
TJ-80A
energy, helps reduce standby heat loss
®
piping methods.
TJV-120A
energy, helps reduce standby heat loss
TJ-80S
energy, helps reduce standby heat loss
TJV-120M
energy, helps reduce standby heat loss
TJV-200-M - 175 GALLONS
with 200 gallons of storage.
protection
5 YEAR WARRANTY
If the tank should leak any time during the first 5 years, under the terms of the warranty, A. O. Smith will repair or replace the tank. Installation, labor, handling and local delivery are extra. For complete information, consult the written warranty.
TJ-80S, TJ-80A
TJV-120A, TJV-120M
& TJV-200M
120 Gallon Model
(FOR SELECT MODELS)
SUGGESTED SPECIFICATION
Storage tank shall be A. O. SMITH glasslined storage tank. Tank shall be ________ “ x ________ “ and have a nominal capacity of _________ gallons. Tank(s)
shall have threaded openings as shown on drawings. Interior of tank(s) shall be glasslined with an alkaline borosilicate composition which has been fused to the
steel by
be provided. Tank shall have a working pressure of _________ psi. Tank shall have a
ring at a temperature of . lass coating shall be continuous over the entire inner surface of the tank. Outer acket shall have a baked enamel
nish. Meets minimum thermal insulation re uirements of the .S. epartment of nergy and current edition of ASH A I S A . . athodic protection shall
ve year limited warranty as outlined in the written warranty.
April 2015R
AOSTT35100
Page 1 of 2
Page 2
Commercial Storage Tanks
54 7/8"
42 3/4"
32 1/4"
3/4" NPT
(ANODE)
19 1/2"
11"
9 3/4"
TJV-120M
TJ-80A
26 1/2"
3/4" NPT REAR
2" NPT
3/4" NPT
(ANODE)
1" NPT
2" NPT
2" ASME INSPECTION OPENING (PLUGGED)
2" NPT
FRONT & REAR
ASME PLATE
UNDER COVER
3/4" NPT REAR
3/4" NPT
FRONT
2" NPT
FRONT & REAR
2" ASME INSPECTION OPENING (PLUGGED)
TJ-80S
2" NPT
3/4" NPT
(ANODE)
25 1/4"
2" NPT FRONT & REAR
3/4" NPT REAR
63"
51 7/8"
47"
16"
7"
3 3/4"
3/4" NPT REAR
3/4" NPT
FRONT
2" NPT FRONT & REAR
TJV-120A
2" NPT
1" NPT
1-1/4" NPT
(ANODE)
29 3/8"
1" NPT
FRONT
2" NPT
FRONT
62"
54 1/4"
42 1/4"
15"
11"
4 1/8"
3 1/2"
3/4" NPT
FRONT
2" NPT
FRONT & REAR
2" NPT
FRONT
2" ASME INSPECTION OPENING (PLUGGED)
77"
64"
17 1/4"
12 1/4"
TJV-200M
32"
3/4" NPT
(ANODES)
2" NPT
1" NPT
3/4" NPT
2" NPT
ASME RATING PLATE AND HAND HOLE LOCATED
UNDER COVER
17 1/4"
12 1/4"
61 3/4"
50 1/2"
3/4" NPT
44 1/2"
21 1/4"
9 3/4"
28"
1" NPT
2" ASME INSPECTION OPENING (PLUGGED)
ASME PLATE
LOCATED UNDER
COVER
2" NPT FRONT
2" NPT FRONT & REAR
17 3/4"
10 3/4"
2" ASME INSPECTION OPENING (PLUGGED)
For Technical Information and Automated Fax Service, call 800-527-1953. A.O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
April 2015R
www.hotwater.com
AOSTT35100
Page 2 of 2
Loading...