A. O. Smith HW-670 User Manual

BURKAY® HOT WATER
Hot Water Supply Boiler
SUPPLY BOILER
FEATURES
ALL NON-FERROUS WATERWAYS
All castings are made of Bronze or Brass
Brazed joints or flare union construction make the boiler immune to the effects of
thermal shock and thermal cycling
A great boiler for domestic hot water supply
EFFICIENT COPPER COIL COMBUSTION CHAMBER
The combustion chamber is a heat exchanger formed from a two passage coil of tightly
wound continuous copper tube
Water circulating through this coil surrounds the main burner and captures the
radiant heat
A wrap of insulation on the outside of the coil retains the heat captured by the
circulating water
COPPER HEAT EXCHANGER
Directly above the coil and the main burner is a compact, horizontal, copper
fin tube heat exchanger
The flue gases must pass through this efficient heat exchanger before leaving
the boiler
This unique Burkay coil and heat exchanger design provide maximum heat
transfer and proven field durability
BURKAY® BURNER MAXIMIZES EFFICIENCY
The patented Burkay burner uses primary air injection at up to 72 individual orifices
plus secondary entrainment of air
Approved for installation on combustible floors as shipped from factory.
HW-300
through
HW-670
HW - INDOOR INSTALLATION ONLY
GAS VALVES
Slow opening redundant gas valves ensure smooth light-off without flame roll-out
or pilot outage
THERMAL BALANCER
Patented pump delay system that allows boiler and pump to run simultaneously but
delays pump shut off at end of heating cycle to remove usable heat from the heat exchanger and reduce the scale forming tendencies of motionless hot water
AUTOMATIC SAFETY CONTROLS AND ELECTRONIC IGNITION
Proven pilot ignition system provides flame failure response in under one (1) second
Redundant high limit controls and gas valves assure safe shutoff in the event of
overheating or flame failure
Requires 120V 60Hz, maximum inlet gas pressure of 14” WC and activation of boiler by
external temperature control
WORKING PRESSURE
ASME approved, hydrostatically tested and certified for 160 psi
Ships with ASME 125 psi relief valve
COMPLIANCE
These models meet the thermal efficiency and standby loss requirements of the U.S.
Department of Energy and current edition ASHRAE/IESNA 90.1.
LIMITED WARRANTY OUTLINE
Consult written warranty or contact your A. O. Smith sales representative
A. O. Smith Corporation • 500 Tennessee Waltz Parkway • Ashland City, TN 37015 • 800-527-1953 Toll-free USA
www.hotwater.com
Page 1 of 2
Revised September 2014 AOSDG25600
TABLE 1. DIMENSIONS AND CAPACITY DATA
FIGURE 1. DIMENSIONS
FIGURE 1. DIMENSIONS
LOCATION OF MANUAL MAIN SHUTOFF VALVE OUTSIDE JACKET WHEN CODE REQUIRE (NOT SUPPLIED)
Hot Water Supply Boiler
DIMENSIONS IN INCHES
Overall height 65 (1651) 57-1/8 (1451) 57-1/8 (1451) 68-5/16 (1735) 68-5/16 (1735)
A
Height to Top of Jacket 43-1/4 (1099) 45-1/8 (1146) 45-1/8 (1146) 56-1/4 (1429) 56-1/4 (1429)
B
Floor to Center Line Water Outlet 36 (914) 38-3/4 (984) 38-3/4 (984) 46 (1168) 46 (1168)
C
Diameter of Jacket 25-1/4 (641) 27 (686) 27 (686) 27 (686) 27 (686)
D
Floor to Center Line Water Inlet 12 (305) 12 (305) 12 (305) 1 2 (305) 12 (305)
E
Draft Diverter Outlet Diameter 8 (203) 10 (254) 10 (254) 10 (254) 12 (305)
F
Floor to Center Line Gas Inlet 16-1/2 (419) 16-3/4 (425) 16-3/4 (425) 8 (457) 18 (457)
G
Overall Depth 29-5/8 (753) 31-1/2 (800) 31-1/2 (800) 36-1/2 (927) 36-1/2 (927)
H
Support Height 9 (229) 9 (229) 9 (229) 9 (229) 9 (229)
J
Width of Control String (approx.) 14 (356) 14 (356) 14 (356) 11 (279) 11 (279)
K
Pipe Size of Water Inlet (NPT) 1-1/4 1-1/2 1-1/2 2 2
L
Pipe Size of Water Outlet (NPT) 1-1/4 1-1/2 1-1/2 2 2
M
Pipe Size of Gas Inlet (NPT) 3/4 3/4 1 1 1
N
Control String Plus 1/2 Jacket Diameter (approx.) 26-5/8 (676) 27-1/2 (699) 27-1/2 (699) 24-1/2 (622) 24-1/2 (622)
P
Horizontal Length between Water Inlet & Outlet 5-3/8 (137) 5-1/2 (140) 5-1/2 (140) 5-3/4 (146) 5-3/4 (146)
S
Control String from Jacket 5 (127) 5 (127) 5 (127) 7 (178) 7 (178)
T
Approximate shipping weight lbs. (Kilograms) 250 (113) 301 (137) 301 (137) 381 (173) 381 (173)
NOTE: All dimensions in inches (millimeters) except pipe size which is NPT
TABLE 2. FLOW, HEAD AND TEMPERATURE RISE
MODELS
HW 300 300,000 240,000 24 8 16 3 12 2 HW 399 399,000 319,200 32 16 21 7 16 5 HW 420 420,000 336,000 34 18 22 8 21 5.5 HW 520 520,000 416,000 42 12 28 5 26 4
HW 670 Nat 660,000 528,000 53 22 35 10 26 5.5
HW 670 Prop 670,000 536,000 54 22 36 10 27 5.5
NATURAL & PROPANE (LP) GAS
BTU INPUT/OUTPUT
INPUT RATING BTU/HR
MODELS
HW-300 HW-399 HW-420 HW-520 HW-670
TEMPERATURE RISE AND PRESSURE DROP
OUTPUT RATING BTU/HR
NATURAL & PROPANE (LP) GAS
20°F RISE 30°F RISE 40°F RISE
GPM
PD-FT HEAD
GPM
PD-FT HEAD
GPM
PD-FT HEAD
EXTRA OPENING FOR THERMOMETER AND PRESSURE RELIEF VALVE HW-520 AND HW-670
TABLE 3. RECOVERY CAPACITIES
MODELS TYPE OF GAS
HW 300
HW 399
HW 420
HW 520
HW 670 Natural 660,000 193
HW 670 Propane 670,000 196
Hot Water Supply Boiler for domestic hot water purposes shall be Model(s) No. __________________ as manufactured by A. O. Smith or an approved equal. Boiler(s) shall be gas-fired, and design certified by an ANSI approved/accredited independent rating laboratory, capable of supplying _____ gph at 100°F temperature rise equipped to burn __________ gas, with input rating of _____ BTU/hr. and bearing the ASME code symbol. Boiler(s) shall be up flow type having all non­ferrous waterways, and employing a copper finned heat exchanger and a tightly wound copper coil combustion chamber with 160 psi working pressure rating. Boiler(s) shall be equipped with an electric gas valve of the step-opening type, an adjustable limit control which will break the electric circuit on temperature rise, intermittent ignition with one (1) second shutdown in the event of pilot flame failure, a gas pressure regulator properly set for the gas to be supplied, and a coil limit switch for shut off in event of excessive water temperature, a certified draft diverter and a fully illustrated instruction manual. Certified for installation on combustible flooring. Outer jacket shall be of baked enamel finish. The coil, heat exchanger and burner shall have a five year limited warranty as outlined in the written warranty.
For Technical Information and Automated Fax Service, call 800-527-1953. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
A. O. Smith Corporation • 500 Tennessee Waltz Parkway • Ashland City, TN 37015 • 800-527-1953 Toll-free USA
www.hotwater.com Revised September 2014
INPUT °F 20 40 50 60 70 80
BTU/HR kW °C (11) (22) (28) (33) (39) (44)
Natural
Propane LPH 5,506 2,753 2,202 1,835 1,573 1,377
Natural
Propane LPH 7,323 3,662 2,929 2,441 2,092 1,831
Natural
Propane LPH 7,708 3,854 3,083 2,569 2,202 1,927
Natural
Propane LPH 9,544 4,772 3,818 3,181 2,727 2,386
300,000 88
399,000 117
420,000 123
520,000 152
GPH 1,455 727 582 485 416 364
GPH 1,935 967 774 645 553 484
GPH 2,036 1,018 815 679 582 509
GPH 2,521 1,261 1,008 840 720 630
GPH 3,200 1,600 1,280 1,067 914 800
LPH 12,113 6,057 4,845 4,038 3,461 3,028
GPH 3,248 1,624 1,299 1,083 928 812
LPH 12,297 6,148 4,919 4,099 3,513 3,074
Suggested Specification
Page 2 of 2
AOSDG25600
Loading...