A.O. Smith GWV - 150, GWV - 200, GWV - 120 User Manual

Page 1
Innovation has a name.
Burkay - Genesis
Semi-Instantaneous Copper High Flow Water Heater
GWV - 120/150/200
Fully room-sealed water heater with an effi cient copper heat
exchanger for a long life • High inputs to supply the most demanding applications • Effi ciency: 81% (gross) • Compact design allows large output from small foot print • Premix burner for low NOx emissions • Suitable for natural or LP gas • Units can be fl ued with
either extensive conventional atmospheric or a room-sealed fl ue
system allowing total fl exibility of siting • ThermoControl provides easy and fl exible control/fault diagnosis • Remote control connection
• Voltage-free contact for general fault indication • Programmable for legionella purge cycle • Unvented kits available • Unit is
supplied with pump and fl ow-switch
Page 2
Burkay - Genesis
Technical specifications
GWV 120
GWV 150
Gas data natural gas 2H (G20)
Input* kW 122.2 152.1 194.3 Output kW 99.0 123.3 157.5 Inlet pressure mbar 20 20 20 Burner pressure (Full Power) mbar 2 x 8.9 2 x 9.3 2 x 8.0 Gas consumption (Full Power)** m Diameter main orifice mm 2.31 2.31 2.31 Burners - 8 10 15 Max. flue gas temperature °C 130 130 130 Flue gas discharge (Full Power) kg/h 211.3 278.7 343.8
3
/h 11.6 14.5 18.5
Gas data propane gas 3P (G31)
Input* kW 108.7 135.9 212 Output kW 90.0 112.5 175.5 Inlet pressure mbar 37 37 37 Burner pressure (Full Power) mbar 2x 13.3 2x 12.7 2x 14.5 Gas consumption (Full Power)** m Diameter main orifice mm 1.50 1.50 1.50 Burners - 8 10 15 Max. flue gas temperature °C 130 130 130 Flue gas discharge (Full Power) kg/h 208 268 369
3
/h 7.8 9.7 15.1
Draw-off capacity***
Max. temperature setting °C 85 85 85 Continuous T=44°C l/h 1935 2410 3078 Continuous T=50°C l/h 1703 2121 2709 Continuous T=55°C l/h 1548 1928 2463
Electrical data
Power consumption W 200 210 350
Power supply VAC/Hz 230 (-15/+10%) / 50 (+/- 1 Hz)
GWV 200
General
Fan rotational speed at ignition r.p.m. 1620 1500 1800 Half load fan speed r.p.m. 2040 2340 2460 Full load fan speed r.p.m. 2340 2700 2820 Pressure differential Pa 80/66 89/75 107/192 Maximum working pressure bar 8
Transport
Weight empty kg 225 250 300 Weight incl. packaging kg 250 275 325 Width packaging mm 795 795 795 Height packaging mm 1075 1075 1075 Depth packaging mm 1605 1760 2165
* Gas data on gross value ** Gas consumption at 15°C and 1013.25 mbar *** Draw-off capacities are based on the capacity of the heat exchanger A Burkay - Genesis water heater should be installed in combination with a storage tank
Page 3
Burkay - Genesis
Dimensions
Top view
Side view
GWV 120
GWV 150
GWV 200
A 835 835 835 B 350 350 350 C 910 1065 1465 D 1230 1495 1895 E 625 625 625 F 150 150 200 G 150 150 200 H 300 300 480 I 160 240 260 J 185 185 185 K 760 760 760 L 345 345 345 M 1500 1680 2100
1 Cold water R11/2 R2 R2 2 Hot water Rp1
1
/2 Rp2 Rp2 3 Gas control R1” R1” R1” 4 Tank drain valve
3
/4” 3/4” 3/4
5 Pressure valve
3
/4” 3/4” 3/4
Dimensions in mm.
All Burkay - Genesis water heaters receive a fi ve years warranty on the heat exchanger.
Page 4
Burkay - Genesis
Installation diagrams
1 Pressure reducing valve 4 Stop valve 5 Non-return valve 6 Circulation pump 9 Drain valve 10 Gas cock 11 Isolating valve 12 Temperature gauge 14 Hot water outlets 15 Expansion relief valve 16 Expansion vessel 17 Three way valve 18 Water tank 19 Float valve 23 Pressure valve
A Cold water B Hot water C Return circulation D Gas supply E Overfl ow pipe H Expansion vent pipe
A.O. Smith unvented system kits utilise combination valves.
Further installation and connection details can be found in the Installation & Commissioning Manual.
Vented
Unvented
Page 5
Burkay - Genesis
Electrical scheme
TERMINAL STRIP CONNECTIONS
Earth N Neutral L Phase input of controller L1 Phase input of system pump L2 Phase input of program-controlled pump
COMPONENTS
A Controller B Ionisation rod C Glow igniter D Gas control 1 E Gas control 2 F Display G Fan H External on/off J n/a K Error signal L n/a M Optional pump N System pump P Double-pole mains switch Q I/O switch control R Temperature sensor (T1 - inlet heat exchanger) S Dummy T Temperature sensor (T3 - Tank) U Temperature sensor (T2 - outlet heat exchanger) V Selection resistor W Air pressure switch X Flow switch
CONTROLLER CONNECTIONS
J2 Connector for power supply to controller J19 Connector for system pump J20 Connector for gas control J21 Connector for program-controlled pump and error signal J29 Connector for room-thermostat (230VAC) J33 Connector for fan control signal J36 Connector for display to controller JP2 Connector for ionisation rod and glow igniter JP3 Connector for temperature sensor T1 JP4 Connector for dummy JP5 Connector for temperatures sensors T2 and T3 JP6 Connector for selection resistor, air pressure switch JP8 Connector for extra ON mode switch JP12 Connector for flow switch
F1 Fuse F3 Fuse
Page 6
Flue systems Burkay - Genesis
Installation options
A Burkay – Genesis water heater should be installed according category B23*, C13 or C33.
C13
Parallel
GWV 120
Diameter (mm) 150 150 200
Max. length not insulated (m) 8 8 8
Max. length not insulated with
condense drain (m) 20 20 20
Max. length insulated (m) 20 20 20
Max. bends 2 2 2
* Please contact A.O. Smith when installing a Burkay - Genesis in a B23 situation.
** When applying a condensation outlet, the distance between the condensation
outlet and the unit may not exceed 8 metres.
GWV 150
GWV 200
The maximum length also applies in B23 installations with different supply and flue duct lengths.
Note: horizontal flue runs must be installed with a fall of at least 5 mm per metre towards the water heater.
C33
Flue systems Burkay - Genesis
Minimum space requirements
GWV 120
Minimal space for wall duct (mm)
V 605 605 1070
W 940 940 1485
X 1245 1245 1495
Y 1090 1090 1090
Minimal space for roof duct (mm)
V 1950 1950 2370
W 1340 1340 1375
X 2395 2395 2780
X ** 1445 1445 1830
Y 1560 1560 1945
Y ** 610 610 995
2 x Ø150 2 x Ø150 2 x Ø200
GWV 150
GWV 200
For the parts numbers of components and flue gas ducts, etc. please refer to the “Maintenance and accessories” chapter.
** Distance without concentric pipe between appliance and roof duct.
Data subject to change INT/1108/GWV/02