AO Smith GPVX75LLP Instruction Manual

Page 1
®
Page 2
EASY INSTALLATION.
GREATER FLEXIBILITY.
To give contractors added installation
PROMAX POWER VENT
In addition to being easier to install, the ProMax Power Vent water heaters have been re-engineered to maximize ef ciency and deliver up to a .70 Energy Factor (EF) that meets the latest
®
ENERGY STAR
quali cations.
 exibility and possibilities with our
ProMax
®
Power Vent water heater, we
designed it with a 3-position rotatable
blower. To simplify installation, our
ProMax Power Vent models vent with
installer-friendly PVC with vent lengths
up to 180 feet. And then we located
all serviceable components within
90 degrees of the front of the unit for
easy access. The A. O. Smith ProMax
Power Vent water heater takes the
frustration out of any installation.
EASY-INSTALL FEATURES:
A versatile Power Vent design with an exclusive 3-position rotatable blower
to adapt to limited space installations.
Combined horizontal and vertical vent runs up to 125 equivalent feet
with 3˝ diameter venting (180 equivalent feet with 4˝ venting on high-input 50- and 75-gallon models).
Factory-installed, CSA-certi ed and ASME-rated T&P relief valve
and a durable, tamper-resistant brass drain valve are positioned to simplify service and installation.
OTHER OUTSTANDING FEATURES:
All models meet ENERGY STAR® requirements and may also qualify for local
utility and rebate programs.
DynaClean™ dip tube optimizes inlet water pressure to minimize cold
water regions within the tank. The self-cleaning action also reduces sediment accumulation on the bottom of the tank.
Hot-surface ignitor is more robust and reliable than standing pilot, and
reduces energy consumption.
Factory-installed built-in heat traps on the water inlet and outlet reduce the
amount of heat lost through piping.
Environmentally-friendly 2-inch-thick foam insulation reduces the amount
of heat loss and maximizes ef ciency.
Models available with 3/4˝ side connections for combination (space
heating) applications.
All models are equipped with a protected  ammable vapor (FV) sensor that
detects the presence of  ammable vapors and automatically disables the burner to prevent their ignition.
Air intake snorkel elevates the combustion air inlet to prevent  ammable
vapors from entering the sealed combustion chamber and igniting.
Eco-friendly Green Choice® gas burner reduces NOx emissions by
up to 33%.
State-of-the-art electronic gas control ensures more precise temperature
control and features an LED indicator to provide operation status and diagnostic information.
Page 3
A
A
G
6-YEAR LIMITED TANK
AN
O
N WS FO
ATIO
GASIS
O
R
ONMBUSTION C
A
A
G
EXCLUSIVE 3-POSITION ROTATABLE
BLOWER FOR HEIGHT-RESTRICTED
INSTALLATIONS
TATABLE
TRICTED
B
FRONT-MOUNTED BLOWER JUNCTION
BOX FOR EASY ACCESS
R JUNCTI
C
ACCESSIBLE ANODE ALLOWS FOR
SERVICING WITHOUT REMOVAL OF
BLOWER
R
VAL OF
D
2-INCH-THICK FOAM INSULATION
MAXIMIZES ENERGY EFFICIENCY
N
IENCY
B
E
C
D
AIR INTAKE SNORKEL PREVENTS
AIR INTAKE SN
FLAMMABLE VA
FLAMMABLE VAPORS FROM ENTERING
THE COMBUSTI
THE COMBUSTION CHAMBER
H
COMBUSTION CHAMBER DOES NOT
RE
IRE FLAME
REQUIRE FLAME ARRESTOR
G
E
EXCLUSIVE ELECTRONIC GAS
CONTROL DELIVERS PRECISE
TEMPERATURE CONTROL
E
F
DYNACLEAN
SEDIMENT BUILD-UP AND
IMPROVES ENERGY EFFICIENCY
DIP TUBE REDUCES
EDUCES
IENCY
H
F
AVAILABLE IN NATURAL GAS AND PROPANE.
VAILABLE IN NATURAL
6-YEAR LIMITED TANK AND PARTS WARRANTY.
Page 4
DIMENSIONS
.
953
COM
006
S.
200
201
MODEL
NUMBER
SERIES HEIGHT
TO TOP OF
BLOWER
HEIGHT TO
TOP OF TANK
DIAMETER OVERALL
ABCDEFGGH
GPVL 40 200 59 49 5⁄8
GPVT 40 200 68 1⁄2
GPVL 50 200 60 1⁄8
GPVT 50 200 68 1⁄8
GPVX 50L 200 61 1⁄8
GPVX 75L 200 70 5⁄8
LL DIMENSIONS IN INCHE FOR SIDE CONNECT MODELS, ADD “L” TO MODEL NUMBER, E.G. GPVT 40L. NATURAL GAS MODELS CITED ARE SERIES
LL MODELS RATED FOR INSTALLATION AT ALTITUDES UP TO 10,100 FT.
59 1⁄4
50 3⁄4
58 3⁄4
52 24 31 1⁄8
61 1⁄4
. PROPANE MODELS ARE SERIES
22 29 1⁄8
20 27 1⁄8
24 31 1⁄8
22 29 1⁄8
26 33 1⁄8
SPECIFICATIONS
MODEL
NUMBER
GALLON
CAPACITY
INPUT BTU/H
ENERGY FACTOR
FIRST HOUR
RATING
USG
DEPTH
HEIGHT
TO DRAIN
11 14 1⁄4
11 14 1⁄4
11 14 1⁄4
11 14 1⁄4
11 14 1⁄4
11 14 1⁄4
.
RECOVERY
90 °F/50 °C RISE
GPH
HEIGHT TO GAS INLET
HEIGHT TO
T&P
HEIGHT TO
UPPER SIDE
CONNECT
42 1⁄2
53 1⁄8
43 3⁄4
51 3⁄4
44 ½ 44 1⁄2
N/A N/A
53 1⁄8
N/A N/A
51 3⁄4
HEIGHT TO
LOWER SIDE
CONNECT
15 1⁄4 176
15 1⁄4 192
15 1⁄4 212
53 53 15 1⁄4 277
VENT LENGTHS
MODEL
NUMBER
MAXIMUM
VENT LENGTH (EQ. FT.)
Ø2˝ Ø3˝ Ø4˝
SHIPPING
WEIGHT
LBS.
174
198
GPVL 40 40 40,000 0.70 73 44.7
GPVT 40 40 50,000 0.70 90 55.9
GPVL 50 50 40,000 0.70 90 44.7
GPVT 50 50 50,000 0.70 96 55.9
GPVX 50L 50 62,000 0.70 110 69.3
GPVX 75L 75 72,000 0.68 155 80.4
For Technical Information and Automated Fax Service, call 800-527-1953.
A. O. Smith Corporation reserves the right to make product changes
r improvements without prior notice
GPVL 40 50’ 125´ 180´ GPVT 40 50´ 125´ 180´
GPVL 50 50´ 125´ 180´
GPVT 50 50´ 125´ 180´
GPVX 50L N/A 50´ 125´ GPVX 75L N/A 50´ 125´
A. O. SMITH
TENNESSEE WALTZ PARKWAY
ASHLAND CITY, TN 37015
-527-1
WWW.HOTWATER.
AOSRG01
Loading...