A.O. Smith GPD-50, GPD-40 LP, GPD-75 LP, GPDL-40, GPD-50 LP Technical Documents

...
Residential Gas Water Heaters
DIRECT VENT
Features
DIRECT VENT DESIGN
One-pipe, dual-channel closed system draws all make-up air from outside the home, eliminating problems caused by insufficient indoor ventilation and is FVIR compliant.
Horizontal air intake and venting on all models up to 80 inches from outside wall with no electrical power needed.
INTELLIGENT CONTROL LOGIC
The internal microprocessor provides enhanced operating parameters and tighter differentials for precise sensing and faster heating response to optimize performance
DYNACLEAN™ DIFFUSER DIP TUBE
SELF-POWERED ELECTRONIC GAS VALVE
Uses a thermopile to generate the power needed to operate the electronic gas control without requiring an external power source.
®
DIAGNOSTICS
The electonic gas control incorporates and LED status indicator that monitors system operation and service diagnostics.
PUSH BUTTON PIEZO IGNITOR
Makes lighting pilot fast and easy with one hand push button spark ignition.
HEAT TRAP NIPPLES
Factory-installed.
DURABLE TAMPER-RESISTANT BRASS DRAIN VALVE
PERMAGLAS
Provides corrosion resistance.
®
GLASS COATING
CSA CERTIFIED AND ASME RATED T&P RELIEF VALVE
8-YEAR LIMITED TANK & 6-YEAR PARTS WARRANTY
For complete information, consult written warranty
Series 200/201
May 2013
Page 1 of 2
CANRG45701
Residential Gas Water Heaters
DIRECT VENT
MODEL
NUMBER
SERIES
HOUR
RATING
ENERGY FACTOR
GAL. CAP.
GALLONS
FIRST
GDV-40
GDVT-50
GDV-75
200 73 0.60 37 38,000 37 68 54-3/4 22-1/4 16 12-1/4 45-1/4 Co-Axial 167
200 88 0.58 50 50,0005576 64-3/4 22-1/4 16-1/4 12-1/2 55-1/2 Co-Axial
200 131 0.57 75 55,000 60 76 65-3/4 26-1/416-1/4 12-1/2 55-1/2 Co-Axial 310
Recovery capacities based on actual performance tests. * Dual-channel system has 3˝ vent pipe inside 6˝ air intake pipe, for the 40 & 50–gallon models.
The 75 gallon model uses a 4” x 7” co-axial pipe. All Models Have 2” Foam Cavity. Water connection 3/4” male all models. 75 gallon water connections are 12” on center. ** Allow 25 1/4¨ for 40 and 50–gallon models and 29 1/2¨ for 75–gallon models for front–to–back dimensions for air intake at the rear of the heater. Propane units are Series 201 All models are certified from sea level to 7,700 ft. elevations.
INPUT
BTU
PER HOUR
RECOVERY@
90ºF RISE
GALLONS
PER HOUR
Important! Vent Installation and Termination Requirements
Maximum horizontal vent distance is 80” to outside of exterior wall.
Minimum horizontal vent distance is 17” to outside of exterior wall.
Vent pipes may be trimmed (cut) for short vent installations.
For vent installation less than 30” the vent restrictor is required.
Place restrictor over the flue outlet on heater before installing the outlet
vent pipe to the heater.
Recommended installation height for the heater vent pipe should be
68” for 40 gallon models and 76” for the 50-gallon and 75-gallon
models (vent height).
Offset Vent Arrangement
1. When replacing an existing direct vent model, the new vent pipe may drop from the minimum vent height as much as 7 1/4” to exit through the existing vent opening in the exterior wall.
2. Vent may have one horizontal 90 degree turn before exiting through exterior wall (Do not combine both offset vent arrangements in one installation) (See examples in the installation manual)
High Rise Vent Arrangement
3. When vent termination is more than 80” above the base of the heater. The horizontal vent run must be a minimum of 22” from the center of the heater to the outside exterior wall surface. (See example in the installation manual)
Vent termination clearance hole through the exterior wall should be approximately 7” diameter. Snow accumulation and drifting should be considered when locating the termination. An optional wire grill vent cap protector is available through the parts department. Part number 9006627005. See the installation manual for complete installation and venting requirements.
A
B
DIMENSIONS IN INCHES
A B C** D E F
40 & 50 gal.
25-1/4
25-1/4
75 gal.
29-1/2
MIN VENT
17
MAX VENT
80
6” DIA. on 40 & 50 Gal. Models
7” DIA. on 75 Gal. Models
6 DIA.
C
F
D
FRONT
E
VENT
OUTLET*
TOP
T&P
42°
47°
EXTERIOR
WALL
APPROX.
SHIPPING
WEIGHT
(LBS)
187
DRAIN
75 gal. vent termination cap is not interchangeable with vent cap on 40 & 50 gal. models
For Technical Information, call 1-888-479-8324. A.O. Smith Corporation reserves the right to make produ ct changes or improvements without prior notice.
May 2013
www.hotwatercanada.ca