A. O. Smith GPD-40L User Manual

®
Residential Gas Water Heaters
POWER DIRECT-VENT
POWER DIRECT VENT DESIGN
n
ProMax SL Power Direct Vent residential gas models are equipped with FVIR technology to meet Phase III of the ANSI Z21.10.1 standards for the resistance to flamable vapor ignition and resistance to lint, dust and oil accumulation tests.
n
SIDE-MOUNTED RECIRCULATING TAPS
n
For installation with combination space heating/potable water heating applications (such as the ProMax XL Heat Exchanger) or any system requiring are circulating hot water loop.
INTELLI-VENT™* GAS CONTROL
n
Equipped with silicon nitride hot surface igniter and advanced electronics for precise control of water temperature and simplified system diagnostics.
®
HEAT TRAP NIPPLES
n
Standard on all models.
QUIET MODULAR BLOWER
n
With 110 /120 Volt electrical system (rating 3 amps or less), with 6-foot cord, standard 3-prong male
connector.
DYNACLEAN™ DIFFUSER DIP TUBE
n
Reduces lime and sediment buildup, maximizes hot water output. Made from long-lasting PEX cross-
linked polymer.
GREEN CHOICE® GAS BURNER
n
Patented“Eco-Friendly”design reduces NOx emissions by up to 33% and complies with requirements
of less than 40 ng/j for low NOx.
MAGNESIUM ANODE RODS
n
Provides long-lasting protection against tank corrosion.
DURABLE TAMPER-RESISTANT BRASS DRAIN VALVE
PERMAGLAS
®
GLASS COATING
CSA CERTIFIED AND ASME RATED T&P RELIEF
CODE COMPLIANCE
n
UBC, SBCC, CABO, HUD, BOCA National codes, Current edition of ASHRAE/IESNA 90.1 and 2004 NAECA
DESIGN-CERTIFIED BY CSA INTERNATIONAL
n
According to ANSI Z21.10.1 - CSA 4.1 Standards governing storage-type water heater.
6-YEAR LIMITED TANK AND PARTS WARRANTY
n
For complete information, consult written warranty.
* Intelli-Vent™ is a registered trademark of the Emerson Electric Company
Revised May 2012
Low Lead Content
Page 1 of 2
AOSRG46500
®
MODEL
FIRST
ENERGY
GALLON
BTU BTU RECOVERY
R
DIMENSIONS IN INCHES APPROX.
NUMBER
HOUR
FACTOR
CAPACITY
INPUT OUTPUT 90ºF RISE
VALUE
SHIPPING
RATING PER HOUR PER HOUR GALLONS
A B C D E F G H
WEIGHT
GALLONS NATURAL NATURAL PER HOUR (LBS.)
GPD-40L 73 .59 40 40,000 † 30,000 † 41 16 57 48-1/2 21 15 8 42 17 42 224
GPDX-50L 80 .58 50 65,000 † 47,500 † 64 16 69-1/2 61 21 15 8 54-1/2 17 54-1/2 232
GPD-75L 123 .53 75 70,000 † 53,200 † 72 16 71-1/2 61-1/2 26-1/4 15-1/2 8 54-1/2 17 54-1/2 352
GPDX-50L is supplied with 5’ of 3” ABS vent pipe and must be used for the first 5’ of the exhaust outlet vent system. GPD-75L is supplied with 5’ of 3” CPVC vent pipe and must be used for the first 5’ of the exhaust outlet vent system. Recovery capacity based on actual performance tests. Water Connections – 3/4" Male on all models. † Propane Gas – 40-Gallon:36,000 BTU input,27,360 BTU output.
50-Gallon: 60,000 BTU input, 43,800 BTU output. 75-Gallon: 65,000 BTU input, 49,400 BTU output.
IMPORTANT: VENTING AND COMBUSTION AIR REQUIREMENTS
Read and follow requirements shown in the Installation Manual for ProMax®Power Direct Vent Gas water heaters dealing with type, placement and length of vent pipe and vent termination, as well as clearances required to provide adequate combustion and proper ventilation.
OPTIONAL CIRCULATING LOOP CONNECTION ASSEMBLIES
Sold separately. Kit Number 9001522 includes two extended PEX lined nipples for side port connections. Kit Number 9002604 is same as 9001522, plus two di-electric unions and 2 brass isolation valves. For use with systems that have a check valve in the air handler or recirculating lines.
IMPORTANT: SEE INSTALLATION MANUAL FOR COMBUSTION AIR AND VENTING SYSTEM REQUIREMENTS FOR POWER DIRECT-VENT WATER HEATERS
F
E
C
D
3" VENT
4"
11.5" MIN.
FROMTOP OF
HEATER TO
CENTER LINE
OF FLUE
1/2" GAS
CONNECTION
B A
G
H
Maximum hydrostatic working pressure: 150 psi
70
105
130
.60
.58
.58
DIMENSIONS IN INCHES APPROX.
SHIPPING
WEIGHT
F
E
C
D
3" VENT
4"
11.5" MIN.
FROMTOP OF
HEATER TO
CENTER LINE
OF FLUE
1/2" GAS
CONNECTION
B A
G
H
Maximum hydrostatic working pressure: 150 psi
Residential Gas Water Heaters
POWER DIRECT-VENT
OPTIONAL 3” PVC HORIZONTAL VENT KIT
(Kit Number 9006475005)
3” DIAMETER VENT/EXHAUST
INSTALL IN ACCORDANCE WITH LOCAL CODES.
For Technical Information and Automated Fax Service, call 800-527-1953. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
Revised May 2012
1 1/2”
www.hotwater.com
1 3/16”
3” DIAMETER PVC INTAKE/COMBUSTION AIR
OPTIONAL CONCENTRIC VENT KIT
4 1/2” DIAMETER
21 1/8”
39”