Residential Gas Water Heaters
®
CLOSED COMBUSTION
POWER DIRECT VENT
POWER DIRECT VENT DESIGN
ProMax Power Direct Vent residential gas models are equipped with FVIR
technology to meet Phase III of the ANSI Z210.1 - 4.1 CSA standards for the
resistance to flammable vapor ignition and resistance to lint, dust and oil
accumulation tests.
The two-pipe closed-combustion system draws all make-up air from
outside the home, eliminating problems caused by insufficient indoor
ventilation.
The system permits combined horizontal and vertical venting and air intake
runs up to 45 feet (including one 90º elbow) using 3” Schedule 40 PVC,
CPVC or ABS pipe for installation versatility.
®
INTELLI-VENT™* GAS CONTROL
Models are equipped with silicon nitride hot surface ignitor and advanced
electronics for precise control of water temperature and simplified system
diagnostics.
FACTORY INSTALLED HEAT TRAP NIPPLES
Standard on all models.
QUIET, MODULAR BLOWER
Equipped with 110/120 volt electrical system (rating 3 amps or less), 6-foot cord,
standard 3-prong male connector.
DYNACLEAN™ DIFFUSER DIP TUBE
Reduces lime and sediment buildup, maximizes hot water output.
Made from long-lasting PEX cross-linked polymer.
COREGARD™ ANODE ROD
Aluminum anode with stainless steel core protects tank against corrosion longer than
ordinary mild steel anodes.
GREEN CHOICE® GAS BURNER
Patents “Eco-Friendly” design reduces NOx emissions by up to 33%,
complies with NOx requirements of less than 40 ng/j
DURABLE TAMPER-RESISTANT BRASS DRAIN VALVE
®
A. O. SMITH BLUE DIAMOND
Provides superior corrosion resistance compared to industry-standard glass lining.
GLASS COATING
CSA CERTIFIED AND ASME RATED T&P RELIEF VALVE
CODE COMPLIANCE: UBC, SBCC, CABO, HUD, BOCA NATIONAL CODES,
ASHRAE/IESNA 90.1 CURRENT EDITION AND 2004 NAECA STANDARDS
DESIGN-CERTIFIED BY CSA INTERNATIONAL
According to ANSI Z21.10.1 - CSA 4.1 standards governing storage-type waterheater.
6-YEAR LIMITED TANK AND PARTS WARRANTY
For complete information, consult written warranty.
®
*Intelli-Vent™ is a registered trademark of the Emerson Electric Company
Revised May 2012
Low Lead Content
Page 1 of 2
AOSRG45900
POWER DIRECT VENT
Residential Gas Water Heaters
®
CLOSED COMBUSTION
MODEL
NUMBER
FIRST
HOUR
RATING
GALLONS
ENERGY
FACTOR
GAL.
CAP.
BTU
INPUT
PER HOUR
NATURAL
RECOVERY
90ºF RISE
GALLONS
†
PER HOUR
R
VALUE*
DIMENSIONS IN INCHES
A B C D E F
BLOWER
OUTLET
GPD-40 70 .60 40 40,000 41 16 57 48-1/2 21 15 8 42 3 224
GPD-50 87 .59 50 40,000 41 16 66 57-1/2 21 15 8 51 3
GPDX-50 105 .58 50 65,000 64 16 69-1/2 61 21 15 8 54-1/2 3 232
GPD-75 130 .58 75 70,000 72 16 71-1/2 61-1/2 26-1/4 15-1/2 8 54-3/4 3 300
GPDX-50 is supplied with 5’ of 3” ABS vent pipe and must be used for the first 5’ of the exhaust outlet vent system.
GPD-75 is supplied with 5’ of 3” CPVC vent pipe and must be used for the first 5’ of the exhaust outlet vent system.
Recovery capacity based on actual performance tests.
Water connections, 3/4" on all models.
†
Propane inputs/recoveries: GPD-40: 36,000BTU/37GPH
*R Value shown is “performance rated.”
IMPORTANT: VENTING AND COMBUSTION AIR REQUIREMENTS
Read and follow requirements shown in the Installation Manual for ProMax
Power Direct Vent Gas water heaters dealing with type, placement and length
of vent pipe and vent termination, as well as clearances required to provide
adequate combustion and proper ventilation.
GPD-50: 38,000BTU/39GPH
GPDX-50: 60,000BTU/59GPH
GPD-75: 65,000BTU/67GPH
®
11.5" MIN.
FROM TOP OF
HEATER TO
CENTER LINE
OF FLUE
C
E
4"
APPROX.
SHIPPING
WEIGHT
(LBS)
232
3" VENT
IMPORTANT:
SEE INSTALLATION MANUAL FOR COMBUSTION AIR AND VENTING
SYSTEM REQUIREMENTS FOR POWER DIRECT VENT WATE
HEATERS
OPTIONAL 3” PVC HORIZONTAL VENT KIT (Kit Number 9006475005)
INSTALL IN ACCORDANCE WITH LOCAL CODES.
3” DIAMETER
VENT/EXHAUST
1 3/16”
1 1/2”
3” DIAMETER PVC
INTAKE/COMBUSTION AIR
OPTIONAL CONCENTRIC VENT KIT
For Technical Information and Automated Fax Service, call 800-527-1953. A.O. Smith Corporation reserves the right to make produ ct changes or improvements without prior notice.
Revised May 2012
www.hotwater.com
4 1/2” DIAMETER
21 1/8”
39”
F
BA
1/2" GAS
CONNECTION
D
Maximum hydrostatic working pressure: 150 psi
Page 2 of 2
AOSRG45900