A.O. Smith GCF-40, GCF-40 LP, GCF-50, GCF-50 LP, GCFL-40 Technical Documents

...
Residential Gas Water Heaters
FEATURES AUTOMATIC FLUE DAMPER
Increases efficiency as it automatically opens and closes to reduce heat loss in
the standby mode.
ENERGY STAR® QUALIFIED
ELECTRONIC GAS CONTROL
Intelligent control logic provides enhanced operating parameters and tighter
differentials for precise sensing and faster heating response to optimize performance.
DIAGNOSTICS
The electronic gas control incorporates an LED status indicator that monitors
system operation and service diagnostics.
ELECTRONIC IGNITION
Heater operates with an automatic pilot relight system that shuts off the pilot
during stand-by modes to reduce gas consumption and eliminates nuisance pilot outage issues associated with standing pilot models.
POWER REQUIREMENTS
Plugs into standard 110/120v outlet (10 foot power cord included).
DYNACLEAN™ DIFFUSER DIP TUBE
Helps reduce lime and sediment buildup, maximize hot water output. Made
from long-lasting PEX cross-linked polymer.
COREGARD™ ANODE ROD
An A. O. Smith exclusive. Anode has stainless steel core, protects tank against
corrosion longer than ordinary steel anodes.
DURABLE BRASS TAMPER-RESISTANT DRAIN VALVE
BLUE DIAMOND
Provides superior corrosion resistance to industry-standard glass lining.
®
GLASS COATING
CSA CERTIFIED AND ASME RATED T&P RELIEF VALVE
Top-mounted T&P Relief Valve available as option on all models.
CODE COMPLIANCE
Meets and exceeds NRCan energy efficiency requirements
Models are complient to the B.C. Energy Efficiency Act Standards
DESIGN-CERTIFIED BY CSA INTERNATIONAL
According to ANSI Z21.10.1 - 4.1 CSA Standards governing
storage-type water heaters.
FLAMMABLE VAPOUR IGNITION RESISTANT COMPLIANT DESIGN
8-YEAR LIMITED TANK AND 6-YEAR LIMITED PARTS WARRANTY
For complete information, consult written warranty or A. O. Smith Water Products Company.
SERIES 100
Page 1 of 2
August 2013
CANRG45250
CANRG45250_SPEC_SHEET_v01.indd 1 9/6/2013 1:07:18 PM
Residential Gas Water Heaters
RESIDENTIAL GAS MODELS - SERIES 100
BTU
PER
RECOVERY
90°F RISE GALLONS
PER HOUR
FOAM
THICKNESS
(INCHES)
DIMENSIONS IN INCHES
A B C D E F
DRAFT
HOOD
OUTLET
MODEL
NUMBER
TALL MODELS
GCF-40 100 67 .67 40 40,000 42 2 64-1/4 58-1/4 20 13 8 51-3/4 3 or 4 152
GCF-50 100 81 .67 50 40,000 42 2 63-1/2 57-1/4 22 13 8 50-1/4 3 or 4 167
SHORT MODEL
GCFL-40 100 67 .67 40 40,000 42 2 54 47-3/4 22 13 8 41 3 or 4 149
GCFL-50 100 81 .67 50 40,000 42 2 55-3/4 49-1/2 24 13 8 42-1/2 3 or 4 183
Recovery capacity based on actual performance tests. Water Connections - 3/4” on all models. External heat trap nipples are factory-installed on all models All models are ENERGY STAR® qualified. All models are certified from sea level to 10,100 ft. elevations *Propane (LP) gas - 37,000 BTU input for 50-gallon models and 36,000 BTU for 40-gallon models GCVL 50 not available for Propane
SERIES
FIRST
HOUR
RATING
GALLONS
ENERGY FACTOR
(EF)
GALLON
CAPACITY
INPUT
HOUR
NATURAL
ANODE ROD
HOT
CONNECTION
APPROX.
SHIPPING
WEIGHT
(LBS)
BC
COMPLIANT
T&P VA LVE
1/2" GAS CONNECTION
COLD CONNECTION
E
C
A
B
F
D
Maximum Hydrostatic Working Pressure: 150 PSI.
For Technical Information call 1-888-479-8324. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
August 2013 Page 2 of 2
www.hotwatercanada.ca
CANRG45250_SPEC_SHEET_v01.indd 2 9/6/2013 1:07:19 PM
CANRG45250