Date: December 20, 1999 No. 137 Rev. 2
Subject: Gas Water Heater Conversion Policy
To: All Accounts
* This supersede all previous letters and field bulletins concerning residential and commercial water heater conversion.
ULLETINULLETIN
TERTER
TER
TERTER
GAS WATER HEATER CONVERSION POLICY
All A.O. Smith Water Products Company’s residential and commercial gas water heaters are designed certified by CSA or UL,
under ANSI Standards for operation on one type of gas only, as indicated on the water heater’s model number and rating
plate.
A.O. Smith realizes that there may be certain situations where a field conversion may be necessary and in order to facilitate
such a conversion, A. O. Smith complies with CSA or UL regulations ensuring that a field conversion be appropriately and
safely completed.
An improper field conversion from one type of gas to another could cause potentially dangerous conditions that may cause an
explosion or fire resulting in property damage, bodily injury or both.
A.O. SMITH WILL ONLY ALLOW THE CONVERSION OF GAS WATER HEATERS FROM LP GAS (PROPANE) TO
NATURAL GAS. THE CONVERSION OF A GAS WATER HEATER FROM NATURAL GAS TO LP GAS (PROPANE) IS
NOT ALLOWED UNDER ANY CIRCUMSTANCES.
A.O. Smith will provide kits as demand warrants through our Parts Department, phone no.
1-800-433-2545. Prices, dimensions and specifications are subject to change without notice.
Each conversion kit is to be installed by an A.O. Smith service agent or a gas utility serviceman in accordance with
A.O. Smith’s written instructions and all codes and requirements of the authority having jurisdiction. Failure to follow
instructions could result in serious injury or property damage. The utility performing this work assumes responsibility for
this conversion.
Changing the Input on Gas Water Heaters
The only changes to the input of a gas water heater allowed are:
• Adjustments to match that shown on the rating plate of the heater. The installation instructions supplied with the
heater indicate if adjustments to input are a required procedure.
• Changes made as required to adjust the heater for proper operation at high altitude as determined by a qualified
service technician. Service manuals include the proper procedure for adjusting heaters at high altitudes.
Conversion of Gas Water Heaters
The conversion of LP gas (Propane) to Natural gas is ONLY allowed providing:
• The conversion is done as part of a gas utility’s program where propane appliances were installed anticipating the
completion of natural gas service to the area. The conversion must be done under the direct supervision of the
utility and by their service representatives.
Claims of damage or injury arising from the unauthorized conversion of any A.O. Smith water heater not design certified for
conversion will be the complete and total responsibility of the person or entity making the conversion.
If you have any questions regarding the above policy, please contact the A.O. Smith Parts Department at 1-800-433-2545 or
our Technical Information Center at 1-800-527-1953.
A.O. SMITH WATER PRODUCTS CO., INC.
5621 W. 115TH STREET • ALSIP, ILLINOIS 60803
FAX: 1-800-433-2515 • www.hotwater.com
Printed in the U.S.A. 2574 04/00 No. 137 Rev. 2
PHONE: 1-800-433-2545

PSD-1-279
RESIDENTIAL WATER HEATER PARTS liST
MODELS FSGH/PGXH-30, 40 & 50
SERIES: 240/241
FLAME
;PREADER
PART NO.
181101
29
SMA R99 MODELS ONLY
.,..:;
PRINTED IN U.S.A.
-~... -~ ~..
PART NO. 181--1
A.O. SMITH WATER PRODUCTS CO., INC.
PHONE' 1.800-433-2545 . FAX: 1-800-433-2515 . WWW.HOTWATER.COM
5621 W. 115TH STREET. ALSIP, ILLINOIS 60803
(~
March 1997

Item
1
ANODE
FSGH & 'T' Mooels PGXH & 'T' Mooels BURNER ASSEMBLY, MAIN - Natural .
2
BURNER ASSEMBLY, MAIN - Propane
3
Burner Head - Natural Burner Head - Propane Orifice, Main Burner - Natural... Orifice, Main Burner - Propane Burner Ass~bly, Pilot - Natural Burner Ass~bly, Pilot - Propane... ...
4
5
6
7
Thermocouple Tube, Main Burner- Natural Tube, Main Burner - Propane ... Tube, Pilot ... ... ... Dirt Leg Assembly- Propane DOOR
8
9
Description
FSGH/PGXH-30
240/241
43817-25
180618-44
182725
182725-1
182730
182730
181508-31
181791-50
1B2Z29.
182729-1
~
182727
182728
23925-20
181206
FSGH/PGXH-40
240/241
43817-29
180618-42
182725-15
182725-16
182730
182730
181508-31
181791-50
1S21.29.
182729-1
~
182727
182728
23925-20
181206
FSGH/PGXH-50
240/241
43817-35
180618-44
182725-4
182725-5
182730
182730
181508-31
181791-50
162Z29.
182729-1
2a§15.
182727
182728
23925-20
181206
10
Outer Inner Draft HocxJ Flue Baffle ... ... ... Flue Restrictor . Hanger, Baffle HEAT TRAP ('T' Models)
11
12
13
14
15
16
.-
18
Inlet Outlet LABEL
. Flammable Vapor Warning . Lighting & Operating . Scald Warning . T~perature . Instruction Manual Nut, Compression.. Pipe Collar... ... Spacer, Inlet Tube ... THERMOSTAT
19
20
21
22
23
24
25
26
Natural.. ... ... Propane... ...
27
Tube, Inlet.. ... VALVE
28
29
Drain Main Gas Shutoff
8MR 844
Heat Trap, Inlet Tube
16
Tube. Inlet
28
180522
180596
181082
181589
34894
181360
181068-35
181235
181139
182798
181138
182734
182732
32365
20172-14
42589-1
1B2l.9.1
1B2Z92
160907-35
26273-5
181737
181295-35
160501-35
180522
180596
181082
181589
34894
181360
181068-35
181235
181139
182798
181138
182734
182732
32365
20172-14
42589-1
1621.91
1.62.Z92
160907-35
26273-5
181737
181295-35
160501-35
180522
180596
181082
181589
34894
181360
181068-35
181235
181139
182798
181138
182734
182732
32365
20172-14
42589-1
1.62Z9.1
1B2.Z92
160907-35
42037-1
181737
181295-35
160501-35
SMRR99
BURNER ASSEMBLY, MAIN - Natural .
2
3
Burner Head Assembly Orifice, Main Burner - Natural Manual, Earthquake Instructioo Nox Flame Spreader Assembly - Natural
4
..
- - -..
182726-0
182730-1
181508-31
181809
181101
160629
182726-1
182730-1
181508-31
181809
181101
160629
182786-3
182730-1
181508-31
181809
181101
160629
SMAS06
Insert Sheet 182552 182552 182552
Manual. Earthquake Instruction 181809 181809 181809
32 Drain Valve - 50 allan on ... 26273-5 26273-5 26273-5
SMA S19
1 ANODE
FSGH & 'T' Mooels ...".."""""""""""""""'.".." 43817-25 43817-29 43817-35
PGXH & 'T' Mooels 180618-44 180618-42 180618-44
SMA K32
BURNER ASSEMBLY, MAIN - Natural
2
4
Note: Underlinoo parts are r~ommendoo stock items for emergency replacement. Consider gas used in your area only.
Orifice. Main Burner - Natural
SMA S45
1 Anode, Outlet ..."... 181125-42 181125-42
Nipple """ 38469-4 38469-4
Pi e Plu , 92650 92650
* Not illustratoo.
"T" denotes heat trap models.
182725-2
181508-32
182725-17
181508-32
182725-6
181508-32
181125-42
38469-4
92650