A.O. Smith FMDV-30, FMDV-40, FMDV-50 User Manual

COMMERCIAL-GRADE
RESIDENTIAL GAS WATER HEATERS
PROLINE® MOBILE HOME DIRECT VENT
COMMERCIAL-GRADE RESIDENTIAL
COMPLIES WITH HUD STANDARDS FOR MANUFACTURED HOUSING INSTALLATION
GAS CONTROL CONVERTIBLE FOR NATURAL AND PROPANE GAS
• For flexibility to meet the varying needs of manufactured housing installations.
SIDE-MOUNTED 3/4˝ COLD WATER INLET
• For ease of installation when cold water supply originates below the structure.
• Top mounted 3/4˝ hot water outlet.
DIRECT VENT MODELS PACKAGE WITH BOTTOM INTAKE AIR VENT
• To draw all combustion make-up air from outside the structure.
OPTIONAL DUCTED AIR INLET KIT FOR DIRECT VENT MODELS
• For use when water heater is installed over a basement.
• Provision for horizontal air inlet ducting. See instruction manual for approved venting distance by model.
GREEN CHOICE® GAS BURNER
• Patented eco-friendly design reduces NOx emissions by up to 33% and complies with Low- NOx emission requirements of less than 40 ng/J.
COREGARD™ ANODE ROD
• Our anode rods have a stainless steel core that extends the life of the anode rod allowing superior tank protection far longer than standard anode rods.
BLUE DIAMOND® GLASS COATING
• Provides superior corrosion resistance compared to industry standard glass lining.
ENHANCED-FLOW BRASS DRAIN VALVE
• Our residential water heaters have a solid brass, tamper resistant, enhanced­flow, ball type, drain valve.
• Uses a standard female hose fitting that allows for fast and easy draining during maintenance.
• Designed for easy operation, this valve includes an integral screwdriver slot that features a 1/4 turn (open/close) radius, which not only permits full straight­through water flow but also a quick and positive shut off.
CODE COMPLIANCE
• Meets UBC, CEC and HUD National Codes.
• Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IES 90.1
• Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA), as amended.
CSA CERTIFIED AND ASME RATED T&P RELIEF VALVE
MAXIMUM HYDROSTATIC WORKING PRESSURE 150 PSI
DESIGN-CERTIFIED BY CSA INTERNATIONAL
• Certified at 300 psi test pressure and 150 psi working pressure.
• Listed according to ANSI Z21.10.1-CSA
4.1 standards governing storage tank­type gas water heaters.
6-YEAR LIMITED TANK AND 6-YEAR LIMITED PARTS WARRANTY
• For complete information, consult written warranty or go to hotwater.com.
© August 2018 A. O. Smith Corporation. All rights reserved.
www.hotwater.com | 800-527-1953 Toll-Free USA | A. O. Smith Corporation | 500 Tennessee Waltz Parkway | Ashland City, TN 37015
Page 1 of 2
AOSRG47106
COMMERCIAL-GRADE
RESIDENTIAL GAS WATER HEATERS
Model
Number
FMDV-30 30 29 60 0.61 30,000 29,000 31 61 58 18 13 14-1/4 52-1/2 3 129
FMDV-40 40 38 57 0.59 32,000 29,000 33 61-3/4 58-3/4 20 13 14-1/4 52-1/4 3 153
FMDV-50 50 47 67 0.56 40,000 37,000 39 60 57 22 13 14-1/4 50 3 168
All models ship from the factory for use with natural gas, a complete propane burner is supplied for converting to propane gas. No option available for top T&P. Water connections-3/4” on all models. All models approved fro installation from sea level to 5,400 ft. elevation. Dimensions and specifications subject to change without notice, in accordance with our policy of continuous product improvement.
Kit Number MIN. MAX.
100285331 - 12” 10
100285333 18” 32” 13
100285412 32” 60” 22
100285414 36” 95” 27
Nominal Capacity
Rated
Storage
Volume
First Hour
Rating Gallon
Btu Input
Per Hour
UEF
Natural
Gas
Approx. Shipping
Weight (lbs)
Btu Input
Per Hour Propane
Recovery
@ 90°F
Rise
Gallon
Per Hour
A B C D E F
HOT WATER OUTLET CONNECTION 3/4˝ NIPPLE SUPPLIED
Dimensions in Inches
ANODE ROD
Outlet
T&P VALVE
Vent
Approx.
Shipping
Weight
(lbs)
APPROVED ROOF JACK KITS
Direct Vent mobile home water heaters must be installed using one of these approved Roof Jack Kits, which must be ordered separately. “Min.”and“Max.”dimensions indicate kit adjust-ability for varying vent distance, as shown in drawing.
A
B
F
C
COLD WATER INLET CONNECTION, 3/4˝ NIPPLE SUPPLIED
VENT KIT / 95 IN.
95˝ MAX. 36˝ MIN.
B
D
VENT KIT / 60 IN.
60˝ MAX. 32˝ MIN.
136˝ MAX. 55˝ MIN.
F
E
*
*Inlet air pipe included 3”diameter for 30 gallon and 40 gallon. 4” diameter for 50 gallon
2˝ MIN.
100˝ MAX.
40˝ MIN.
Adj. 0-30.26° MAX. PITCH 7-12
30.26°
32˝ MAX. 17˝ MIN.
VENT KIT / 32 IN.
72˝ MAX.
25˝ MIN.
VENT KIT / 12 IN.
12˝ MAX.
D
GAS CONNECTOR
1/2˝ FEMALE
52˝ MAX.
18˝ MIN.
E
23˝ MAX.
For technical information call 800-527-1953. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
© August 2018 A. O. Smith Corporation. All rights reserved.
www.hotwater.com | 800-527-1953 Toll-Free USA | A. O. Smith Corporation | 500 Tennessee Waltz Parkway | Ashland City, TN 37015
Page 2 of 2
AOSRG47106