Residential Gas Water Heaters
ENERGY SAVER MANUFACTURED HOUSING
STANDARD VENT AND DIRECT VENT MODELS
COMPLIES WITH HUD STANDARDS FOR MANUFACTURED
HOUSING INSTALLATION
■ Meets the Federal Energy Efciency Standards effective January 20, 2004,
according to the National Appliance Energy Conservation Act (NAECA) of 1992.
FLAMMABLE VAPOR IGNITION RESISTANT (FVIR) COMPLIANT
GAS CONTROL CONVERTIBLE FOR NATURAL AND PROPANE GAS
■ For exibility to meet the varying needs of Manufactured Housing installations.
SIDE-MOUNTED 3/4˝ COLD WATER INLET
■ For ease of installation when cold water supply originates below the structure.
Top mounted 3/4˝ hot water outlet.
DIRECT VENT MODELS PACKAGED WITH BOTTOM INTAKE AIR VENT
■ To draw all combustion make-up air from outside the structure.
OPTIONAL DUCTED AIR INLET KIT FOR DIRECT VENT MODELS
■ For use when water heater is installed over a basement. Provision for horizontal
air inlet ducting. See instruction manual for approved venting distance by model.
GREEN CHOICE® ECO-FRIENDLY GAS BURNER
■ Patented design reduces NOx emissions by up to 33% and complies with
less than 40 ng/j requirements for low NOx emissions.
GLASSLINED TANK
■ For long-lasting protection against corrosion.
ANODE ROD
■ Helps protect against corrosion and maximizes tank life.
CSA CERTIFIED AND ASME RATED T&P RELIEF VALVE
MAXIMUM HYDROSTATIC WORKING PRESSURE 150 PSI
DESIGN-CERTIFIED BY CSA INTERNATIONAL
6-YEAR LIMITED TANK AND 2-YEAR LIMITED PARTS WARRANTY
■ For complete information, consult written warranty.
FMV Model Shown
Revised July 2014
Page 1 of 2
AOSRG46701
Residential Gas Water Heaters
DIMENSIONS IN INCHES
DRAFT
HOOD
OUTLET
APPROX.
SHIPPING
WEIGHT
(LBS.)
MODEL
NUMBER
SERIES
FIRST
HOUR
RATING
GALLONS
ENERGY
FACTOR
GAL.
CAP.
BTU INPUT PER
HOUR NATURAL/
PROPANE
RECOVERY
90˚ RISE
GALLONS
PER HOUR
INSULATION
(INCHES)
A B C D E F
STANDARD ATMOSPHERIC VENT MODELS - See Figure 2
FMV-30 302 55 0.61 30 35,500/32,000 36 2˝ 61-1/2 58 18 13 14-1/4 52 3 or 4 129
FMV-40 302 62 0.59 40 35,500/32,000 36 2˝ 61-3/4 58-1/4 20 13 14-1/4 51-3/4 3 or 4 153
DIRECT VENT MODELS - See Figure 1
FMD-30 300 49 0.61 30 30,000/29,000 31 2˝ — 58 18 13 14-1/4 52 3 129
FMD-40 300 61 0.60 40 32,000/29,000 33 2˝ — 58-3/4 20 13 14-1/4 51-3/4 3 153
FMD-50 300 77 0.59 50 40,000/37,000 39 2˝ — 57-1/4 22 13 14-1/4 50-1/4 3 168
All models ship from factory for use with natural gas, a complete LP (propane) burner is supplied for converting to propane gas.
Approved Roof Jack Kits for Direct Vent Models
KIT NUMBER MIN. MAX. SHIP. WEIGHT
Direct Vent Manufacture Housing water heaters must be installed
using one of these approve Roof Jack Kits, which must be ordered
separately. “Min.” and “Max” dimensions indicate kit adjustability
for varying vent distance, as shown in drawing.
9002964005 — 12˝ 10
9002965005 17˝ 32˝ 13
9002966005 32˝ 60˝ 27
9002967005 49˝ 96˝ 22
VENT KIT / 96 IN.
ANODE ROD
C
T&P VALVE
96˝ MAX.
49˝ MIN.
36˝ MAX.
55˝ MIN.
VENT KIT / 60 IN.
60˝ MAX.
32˝ MIN.
2˝ MIN.
100˝ MAX.
40˝ MIN.
Adj. 0-22.6
MAX. PITCH 5-12
22.6
32˝ MAX.
17˝ MIN.
VENT KIT / 32 IN.
72˝ MAX.
25˝ MIN.
VENT KIT / 12 IN.
12˝ MAX.
52˝ MAX.
18˝ MIN.
HOT WATER OUTLET
CONNECTION 3/4˝
NIPPLE SUPPLIED
B
D
Direct Vent Models
Figure 1
F
E
G
23˝ MAX.
A
B
F
D
GAS CONNECTOR
1/2˝ FEMALE
COLD WATER INLET
FOR CONNECTION,
3/4˝ NIPPLE SUPPLIED
E
Standard Vent Models
Figure 2
For Technical Information and Automated Fax Service, call 800-527-1953. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
Revised July 2014 Page 2 of 2
www.hotwater.com AOSRG46701