A. O. Smith BTR-151 User Manual

®
Commercial Gas Water Heaters
MASTER-FIT® SERIES ­COMMERCIAL GAS WATER HEATERS
BTR-151(A)
The Master-Fit® BTR-151 and BTR-201 are designed for installation in booster applications, to supply commercial dishwashers with very high temperature water, typically 180ºF. A booster water heater is generally used in conjunction with a standard water heater water delivering hot water at a lower temperature to meet the non-dishwashing needs of a restaurant or other foodservice application.
With a 32-gallon storage tank, these compact units measure only 45’’ high with a hot water outlet in the top and both top and cold water inlets in the front.
THE ELIMINATOR™SELF-CLEANING SYSTEM
• Designed to signifi cantly reduce or eliminate buildup of lime, sand and other sediment inside the tank
• Reduced sediment buildup helps Master-Fit water heaters maintain their rated energy efficiency and reduce water heating costs
• Self-cleaning system also helps prolong tank life
BUILT-IN INDUCED DRAFT BLOWER
• Produces power-induced draft of makeup air prior to burner ignition
• Provides more efficient control of heat through the flue collector
• No draft hood or barometric damper required
RATED AS CATEGORY 1 APPLIANCE
• Can be commonly vented with other Category 1 appliances, using standard metal type “B” vent
PERMAGLAS
• Exclusive process provides superior protection against corrosion
• CoreGard anode rods with stainless steel core provide additional corrosion protection
®
ULTRA COAT GLASS LINING
through
BTR-201(A)
• The Eliminator self-cleaning device operates when cold water is connected through front
INTERMITTENT ELECTRONIC IGNITION
• Eliminates standing pilot
• Includes power ON/OFF switch
• Provides flame failure response in less than one second
CSA/ASME CERTIFIED T&P RELIEF VALVE
MAXIMUM HYDROSTATIC WORKING PRESSURE 160 PSI
80% THERMAL EFFICIENCY CODES AND STANDARDS
• Design-certified by UL (Underwriters Laboratories), according to ANSI Z21.10.3 - CSA 4.3 standards governing storage-type water heaters
• Listed By UL Sanitation as complying with ANSI/NSF-5
• Meets the thermal effi ciency and standby loss requirements of the U. S. Department of Energy and current edition of ASHRAE/IESNA 90.1
• Optional ASME construction available
WARRANTY
• Three-year limited warranty against tank leaks
• For complete warranty information, consult written warranty shipped with water heater, or contact A. O. Smith
December 2012R
Page 1 of 2
AOSCG10400
®
Commercial Gas Water Heaters
CAPACITY, INPUT AND OUTPUT
BTU
MODEL
INPUT
NUMBER
HOUR
BTR-151 150,000
BTR-201 199,900
Gallons
PER
Litres
U.S.Gallons 32 167 GPH 364 242 182 145 104
Litres 121.1 632.1 LPH 1377.7 916 688.9 548.8 393.6
U.S.Gallons 32 216 GPH 485 322 241 194 139
Litres 121.1 817.6 LPH 1835.7 1218.8 912.2 734.3 526.1
TANK
or
SIZE
CAPACITY, INPUT AND OUTPUT
MODEL
NUMBER
inches 45 40
BTR-151(A)
and
BTR-201(A)
cm
ABCDE FG
114.3
101.6 70.5 81.9
FIRST
HOUR
GPH
RATING
27-3/4 32-1/4
RECOVERY-GALLONS or LITRES
PER HOUR AT DEGREE RISE
or
40°F 60°F 80°F 100°F 140°F
LPH
22°C 33°C 44°C 56°C 78°C
DIMENSIONS
15-3/4
40
5
12.7
6-1/2
16.5
1 1/2" NPI
OUTLET
B
E
F
GAS
CONN.
H
63/4
15.2
3/4
1 1/2" NPI
INLET
WATER CONN.
1-1/2
1-1/2
H
15.2cm
C
3.8cm
APPROX. SHIPPING
WEIGHT
STD/ASME
1.5
460/440
181.8
1" NPI RELIEF
VALVE OPENING
G
CLEARANCE
(IBS.)
A
D
SUGGESTED SPECIFICATION
Gas booster water heater(s) shall be A. O. Smith Master-Fit, Model Number ______________, with a 32-gallon storage capacity, an input rate of ___________ BTU/HR, ___________ gas,
and a recovery rate of _____ gallons per hour at a _____ degree Fahrenheit temperature rise, and a maximum hydrostatic working pressure of 160 psi. Unit(s) shall have a fan-assisted
combustion system, providing a power-induced draft of makeup air prior to burner ignition. Unit(s) shall be equipped with intermittent electronic ignition with power on/off
switch, which shall provide fl ame failure response in less than one second. The burner for the unit(s) shall be easily removable. Unit(s) shall be equipped with a CSA Certifi ed and
ASME Rated T&P relief valve, and a 2-3/4’ x 3-3/4’ tank inspection port. The water heater tank shall be glasslined and protected against premature failure in the following
ways: 1. Against electrolytic corrosion by multiple, factory-installed anode rods 2. Against failure due to overheating caused by the buildup of scale, fi lm and other sediment
by a self-cleaning device, positioned inside the tank so that it directs the fl
suspension and exhausted from the water heater on that or successive hot water draws. Unit(s) shall be UL listed to comply with ANSI/NSF-5 for Sanitation. Unit(s) shall
meet the thermal effi ciency and standby loss requirements of the U. S. Department of Energy and current edition of ASHRAE/IESNA 90.1, and be design certifi ed
by UL (Underwriters Laboratories), according to ANSI Z21.10.3 - CSA 4.3 standards governing storage-type water heaters.
For Technical Information and Automated Fax Service, call 800-527-1953. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
December 2012R
www.hotwater.com
ow of inlet water in such a way that microscopic particles of precipitated solids shall be kept in
Page 2 of 2
AOSCG10400
Loading...