A. O. Smith BTP-540A User Manual

®
Commercial Gas Water Heaters
LOW NOx POWER BURNER MODELS
BTP(V)-540A
FEATURES
BTP and BTPV commercial water heaters offer precise power burner performance for commercial applications, plus the flexibility of conventional atmospheric venting, sidewall venting or direct venting. To help ensure optimum performance, A. O. Smith provides a FREE professional start-up that is required on the BTP and BTPV models.
BTP models designed for conventional atmospheric vertical venting.
Barometric draft regulating damper provided. Order Vent Kit Part # 9500007350.
BTPV models designed for horizontal atmospheric sidewall venting or direct venting,
using optional vent kits.
For sidewall venting order Vent Kit Part # 9500007229. For direct venting order Vent Kit Part # 9910001005.
LOW NOx POWER GAS BURNER (NATURAL GAS ONLY)
Pre-mix design with internal Flue Gas Recirculation (FGR) Safety features include internal blocked flue sensor, separate pilot
system, internal thermal cutoff and anti-flashback barrier
FULLY AUTOMATIC CONTROLS
Including safety shut-off, high-temperature limit control Dual thermostat, adjustable from 120º F to 180º F
DRAFT EQUALIZING COMBUSTION CHAMBER
Patented dome system ensures optimum flue loading and efficient heat
transfer by balancing pressure inside combustion chamber
ASME TANK CONSTRUCTION ON ALL MODELS
Rated working pressure: 160 PSI
through
BTP(V)-740A
CSA CERTIFIED AND ASME RATED T&P RELIEF VALVE
GLASSLINED TANK WITH MULTIPLE ANODE RODS
For optimum protection against tank corrosion
FLAME INSPECTION PORTHANDHOLE CLEANOUT
For easy cleanout of sediment from tank bottom
HIGH ALTITUDE INSTALLATION
Adjustable air intake damper easily reset for high-altitude installation by
authorized start-up agent
CODES AND STANDARDS
Meets the thermal efficiency and standby loss requirements of the U.S.
Department of Energy and current edition of ASHRAE/IESNA 90.1
Complies with SCAQMD Rule 1146.2 and other air quality management districts with
similar requirements for low NOx emissions. The BTPV 540 and 650 meet the requirements of
SCAQMD 1146.2 of 14 ng/j or 20ppm and other districts having the same requirements. The BTPV 740 meets code requirements for Texas and other areas of California requiring 30ppm.
WARRANTY
Factory Start-Up is required for activating warranty and assuring maximum operating performance. Contact your local sales representative or Authorized Start-Up Agent to arrange a FREE Certifi ed Start-Up.
Three-year limited tank warranty
For complete warranty information, consult written warranty shipped with water heater,or contact A. O. Smith
Revised October 2012
GAS-FIRED
Low Lead Content
CAPACITY, INPUT AND RECOVERY
MODEL
NUMBER
BTU
INPUT
PER
HOUR
Gallons
or
Litres
TANK
SIZE
FIRST
HOUR
RATING
100°F
RISE
®
RECOVERY-GALLONS
PER HOUR AT
100°F
TEMPERATURE
GPH
or
40°F
4°C
100°F 140°F
56° C
LPH
Commercial Gas Water Heaters
8” WC Minimal Gas Supply Pressure Required For
RISE
78°C
All Models!
BTP 540A
BTPV 540A
BTP 650A
BTPV 650A
BTP 740A
BTPV 740A
Based on 80% Thermal Efficiency. To compensate for effects of high altitude above 2,000’, recovery ratings should be reduced approximately 4% for every 1,000 feet above sea level. Current Draw (120V,60Hz, 1 Phase): 6.0 Amps
US. Gallons 85 583 GPH 1309 523 374
540,000
Litres 321.7 2206.7 LPH 4954.6 1979.6 1415.6
US. Gallons 85 690 GPH 1579 630 450
650,000
Litres 321.7 261 1 .7 LPH 5976.5 2384.6 1703.3
US. Gallons 85 778 GPH 1794 718 512
740,000
Litres 321.7 2944.7 LPH 6790.3 2717.6 1937.9
DIMENSIONS AND WEIGHT - ALL MODELS
Inches or CM
Inches 80-3/4 73 32-1/4 9 26-1/2 26-1/2 93 29-1/2 48-1/2 1” 950 Lbs.
*D dimension is for atmospheric vent size (BTP models). **E dimension is for direct and sidewall vent size (BTPV models). ***Minimum gas supply pipe is 1-1/2”. See Reference Manual, Table 7 for gas supply pipe size. BTPV heaters are available in Natural gas only.
ABCDE F GH 1
CM 205.1 185.4 81.9 22.9 67.3 67.3 236.2 74.9 123.2 - 43 1.8 Kg
DIMENSIONS
GAS
CONN.***
SHIPPING
WEIGHT
SUGGESTED SPECIFICATION
Water heater(s) shall be A. O. Smith Model ________________or equal, with maximum storage capacity of 85 gallons, an input rating of _________BTU/Hr., a recovery rating of ___ GPH at 100º F temperature rise, and minimum thermal efficiency of 80%. Heater(s) shall meet the thermal efficiency and standby loss require­ments of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1, comply with SCAQMD Rule 1146.2 (BTPV 540 and 650 only) and other air quality management districts with similar requirements for s. In addition, heater(s) shall: 1) Include a powered gas burner, redundant main gas valves, gas pressure regulator and flame inspection port. 2) Include a e. and be so marked for a maximum working pressure of 160 PSI. 5) Have a glass-lined steel tank with multiple anodes for corrosion protection, and polyurethane foam insulation. 6) Tank shall have a 3-year limited warranty against corrosion as outlined in the written warranty. Venting: BTP heater(s) shall be supplied with a Barometric Draft Regulator for conventional atmospheric venting. BTPV heater(s) shall be supplied with an optional vent kit allowing for horizontal sidewall venting or direct venting. Burner and Controls: Burner(s) shall be pre-mix design, with internal FGR and thermal cut off, separate spark pilot ignition system, integral blocked flue sensor, glass view port, main gas regulator, automatic gas valve, manual test cock and manual gas shutoff. Burner(s) must be factory-installed, tested and started by an A. O. Smith Authorized BTP Start-up Agent before being placed into operation.
For Technical Information and Automated Fax Service, call 800-527-1953. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
Revised October 2012
www.hotwater.com
Page 2 of 2