A. O. Smith BPD-75 User Manual

®
Commercial Gas Water Heaters
FEATURES
The BPD-75 tank-type commercial gas water heater is intended for light-duty applications such as small offi ce buildings and duplex apartment homes. The BPD-75 features a power direct-vent design, with a factory-installed blower. The blower permits sealed combustion direct-vent operation, with separate venting and air intake runs from outside the structure. The BPD-75 offers installation versatility by allowing venting and intake runs up to 50 feet, using 3” Schedule 40 PVC pipe.
The power direct-vent design also eliminates the potential for performance and safety problems caused by negative air pressure, a problem found in many commercial applica­tions with inadequate indoor ventilation.
DYNACLEAN™ II AUTOMATIC SEDIMENT-CLEANING SYSTEM
• Specially designed dip tube directs incoming cold water to create turbulence in the tank to reduce lime and sediment buildup
• Prolongs tank life, maintains high energy-effi ciency, maximizes hot water output
PERMAGLAS® GLASS-LINED TANK
• Glass lining and anode rod protect steel tank from corrosion
QUIET MODULAR BLOWER
• Built-in safety device prevents pilot or main burner operation if blower is not operating
• Blower has 110/120V electrical system, with maximum 2-amp draw
DURABLE BRASS DRAIN VALVE
CSA CERTIFIED AND ASME RATED T&P RELIEF VALVE
MAXIMUM HYDROSTATIC WORKING PRESSURE 150 PSI
80% THERMAL EFFICIENCY
MODELS
BPD-75
®
STANDARDS
• Design-certifi ed by CSA International, according to ANSI Z21.10.3 - CSA 4.3 standards governing storage-type water heaters
• Meets the thermal effi ciency and standby loss require Department of Energy and current edition of ASHRAE/IESNA 90.1
WARRANTY
• Three-year limited tank warranty
• Consult written warranty shipped with water heater or contact A. O. Smith
February 2013R
ments of the U. S.
Page 1 of 2
AOSCG11300
®
Commercial Gas Water Heaters
MODEL
NUMBER
BPD-75 Propane 75 65,000 112 148 59 42
GALLON
CAPACITY
75 70,000 117 161 64 46
BTU INPUT
PER HOUR
FIRST HOUR
RATING
100°F RISE
RECOVERY – GALLONS PER HOUR
AT °F TEMPERATURE RISE
40° 100° 140 °
DIMENSIONS AND WEIGHT
BCD FG
BPD-75 26 8542 352
(lbS.0)
SUGGESTED SPECIFICATION
Water Heater(s) shall be model BDP-75 AS MANUFACTURED BY A. O. Smith shall be of glasslined design, and gas-fi red, equipped to burn _________ gas and design certifi ed by Underwriters Laboratories under Volume III tests for commercial heaters for delivery of 180°F water, and meets the thermal effi ciency and standby loss requirements of the U. S. Department of Energy and current edition of ASHRAE/IESNA 90.1. Heaters shall have an input rating of _________ and a recovery rating of _________ GPH at a temperature rise of 100°F with a storage capacity of 75 gallons.
Unit(s) shall be direct-vent design, with an automatic blower-powered, two-pipe air intake and exhaust system communicating directly with the outside of the building. The blower shall have a safety device that will not allow the operation of the main burners unless the blower is in operation. Unit(s) shall have a combustion air passage that is internal to the outer jacket of the water heater other than the intake and exhaust connections at the top of the water heater.
Heater tank shall have a 3-year limited warranty against corrosion or sediment buildup as outlined in the written warranty. Fully illustrated instruction manual to be included.