A.O. Smith AOSRG45700 User Manual

Residential Gas Water Heaters
DIRECT-VENT
ProMax® Direct-Vent Features
DIRECT-VENT DESIGN
One-pipe, dual-channel closed-combustion system draws all make-up air from outside the home, eliminating problems caused by insufficient indoor ventilation, and is FVIR compliant
Horizontal air intake and venting on all models up to 80 inches from outside wall, with no electrical power needed.
A. O. SMITH DYNACLEAN™ DIFFUSER DIP TUBE
GREEN CHOICE™ GAS BURNER
Patented “eco-friendly” design reduces NOx emissions up to 33% and complies with Southern California and Texas requirements.
PUSH BUTTON PIEZO IGNITER
Makes lighting pilot fast and easy with one hand push button spark ignition.
HEAT TRAP NIPPLES Factory installed.
DURABLE TAMPER-RESISTANT BRASS DRAIN VALVE
A. O. SMITH PERMAGLAS®GLASS COATING
Protects steel tank from rust.
FACTORY-INSTALLED TEMPERATURE & PRESSURE (T&P) RELIEF VALVE
6-YEAR LIMITED TANK & PARTS WARRANTY
For complete information, consult written warranty or A. O. Smith Water Products Company.
CODE COMPLIANCE: UBC, CEC, SBCC, CABO, HUD, BOCA NATIONAL CODES, ASHRAE/IES 90.1-1999 AND 2004 NAECA
DESIGN-CERTIFIED BY CSA INTERNATIONAL
According to ANS Z21.10.1 standards governing storage-type water heaters.
Revised April 2008
Page 1 of 2
AOSRG45700
Residential Gas Water Heaters
DIRECT-VENT
MODEL
NUMBER
FIRST HOUR
RATING
GALLONS
ENERGY FACTOR
GAL. CAP.
BTU
INPUT
PER HOUR
RECOVERY
90ºF RISE
GALLONS
PER HOUR
DIMENSIONS IN INCHES
A B C D E F
VENT
OUTLET*
APPROX.
SHIPPING
WEIGHT
(LBS)
GDV-40 73 .62 40 38,000 41 68 54-3/4 22-1/4 16 12-1/4 45-1/4 Co-Axial 167
GDV-50 87 .60 50 42,000 45 76 63-3/4 22-1/4 16 12-1/4 54 Co-Axial 185
GDVT-50 88 .59 50 50,000 55 76 64-3/4 22-1/4 16-1/4 12-1/2 55-1/2 Co-Axial 187
GDV-75 131 .59 75 55,000 60 76 65-3/4 26-1/4 16-1/4 12-1/2 55-1/2 Co-Axial 310
Recovery capacities based on actual performance tests. * Dual-channel system has 3˝ vent pipe inside 6˝ air intake pipe, for the 40 & 50 gallon models.
The 75 gallon model uses a 4” x 7” co-axial pipe. All Models Have 2” Foam Cavity. Water connection 3/4” male all models. 75 gallon water connections are 12” on center.
Important! Vent Installation and Termination Requirements
n Maximum horizontal vent distance is 80” to outside of exterior wall. n Minimum horizontal vent distance is 17” to outside of exterior wall. n Vent pipes may be trimmed (cut) for short vent installations. n For vent installation less than 30” the vent restrictor is required.
Place restrictor over the flue outlet on heater before installing the outlet vent pipe to the heater.
n Recommended installation height for the heater vent pipe should be
68” for 40 gallon models and 76” for the 50-gallon and 75-gallon models (vent height).
n Offset Vent Arrangement
1. When replacing an existing direct vent model, the new vent pipe may drop from the minimum vent height as much as 7 1/4” to exit through the existing vent opening in the exterior wall.
2. Vent may have one horizontal 90 degree turn before exiting through exterior wall (Do not combine both offset vent arrangements in one installation) (See examples in the installation manual)
n High Rise Vent Arrangement
3. When vent termination is more than 80” above the base of the heater. The horizontal vent run must be a minimum of 22” from the center of the heater to the outside exterior wall surface. (See example in the installation manual)
n Vent termination clearance hole through the exterior
wall should be approximately 7” diameter.
n Snow accumulation and drifting should be considered
when locating the termination.
n An optional wire grill vent cap protector is available
through the parts department. Part number 9006627.
n See the installation manual for complete installation
and venting requirements.
A
B
D
6” DIA. on 40 & 50 Gal. Models
7” DIA. on 75 Gal. Models
C
E
40 & 50 gal.
MIN VENT
17
MAX VENT
80
6 DIA.
F
25-1/4
25-1/4
75 gal.
29-1/2
TOP
T&P
42°
47°
EXTERIOR
WALL
DRAIN
75 gal. vent termination cap is not interchangeable with vent cap on 40 & 50 gal. models
FRONT
For Technical Information and Automated Fax Service, call 800-527-1953. A.O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
Revised April 2008
www.hotwater.com
Page 2 of 2
AOSRG45700