AO-RO-RM-R
REMINERALIZER REPLACEMENT
for use with AO-US-RO-4000
FRESH FILTERS.
Fresh filters, obsessively engineered to provide you with clean water. Take a few minutes. Change your filters. Whatever your water need – enjoy the next round of clean water.
If you need help or have a question, we’ve got you covered. Give us a call at 877.333.7108.
Once the tank is drained, and the system is no
3
longer under pressure, remove the 3/8" hose from the inlet and outlet of the remineralizer by pushing and holding down the collar while removing the hose.
Insert the white 3/8" hose attached to the
5
faucet into the outlet connection of the new remineralizer by pressing the hose in until it stops.
Connect the remaining hose end (which has
6
the opposite end connected to the RO manifold outlet labeled “Faucet”) to the inlet portion of the remineralizer by pressing the hose in until it stops.
Once the tank has completely filled, inspect
8
for leaks.
If there are no leaks, flush the filter
9
cartridges by turning on the RO faucet and allowing the water to run through the filters until there is no pressure coming out of the RO faucet.
CLEAN WATER.
INSTRUCTIONS:
Remove the remineralizer from
1
the packaging.
Important:
2
• Turn off the cold water valve under the sink.
• Release the pressure from the system by turning on the filtration system faucet.
• Once there is no longer any water coming from the filtration system faucet, you will be ready to change the remineralizer.
IMPORTANT: For the first 36 hours after the initial installation, ensure you periodically inspect for leaks while the system is running and while it is turned off. If a leak occurs, shut off the water supply, open up the filter faucet to release pressure from the system and contact A. O. Smith Support 877.333.7108.
Discard the old remineralizer cartridge.
4
Turn off the filter faucet, turn on the
7
water supply and allow the RO tank to fill up completely (this may take around 2 hours).
10
Turn off the RO faucet, allow 2 hours for the pressure to build in the system. Your RO system is ready to use.
• Rated capacity: 12 months depending on contaminant levels & usage.
For use with municipally treated water only. Do not use with water that is microbiologically unsafe or of unknown water quality without adequate disinfection before or after the system.
A. O. Smith Corporation | P.O. Box 1597 Johnson City, TN 37605-1597 | 877.333.7108