A.O. Smith AH - 290, AHD 290, AHDS 290 User Manual

Page 1
Innovation has a name.
AH AHD AHDS
Air to water heat pump
AH - 290 / AHD 290 / AHDS 290
Air to water heatpump • Storage capacity 285 liter • Very high COP of 3,2 / 3,5 • Suitable for air temperatures between 0°C-35 °C (depending on the model) • Plug and play installation • Easy and user friendly control • Water temperature with the heat pump up to 55°C • Additional electric element of 1,5 kW standard • Water temperature with additional electric element up to 65 °C • Very silent operation • AH 290 basic version with air intake and air outlet indoors • AHD 290 with air intake and air outlet from outside the building and defrost function • AHDS 290 with additional
integrated solar heat exchanger for thermal solar applications
Page 2
AH(D)(DS)
Technical specifications
AH 290
AHD 290
Functioning parameters
Minimum air temperature °C 8 0 ­Maximum air temperature °C 35 35 -
Air flow per hour m
Max hot water temperature heatpump °C 55 55 ­Max hot water temperature heatpump + electric element °C 65 65 -
3
280 280 -
Electrical data
Main electric connection 230(-15%/+10%)/50(+/- 1Hz) Motor AC AC ­Power consumption W 560 560 ­Electric connection A 13 13 ­COP - 3,2 3,5 ­Power consumption electric element kW 1,5 1,5 ­Fan speed r.p.m. 2500 2500 -
General/Cooling info
Heat capacity kW 1,96 1,96 ­Refrigerant R 134 a R 134 a ­Refrigerant filling Kg 0,9 0,9 ­Maximum working pressure tank bar 8 8 ­Sound level (1 meter in front of the unit) dB 56 56 ­Anodes - 1 1 -
Draw-off capacity
Storage capacity l 285 285 -
Maximum temperature setting heatpump °C 55 55 ­Maximum temperature setting heatpump + electric element °C 65 65 -
T
= 10ºC / T
cold
30 min T = 28 °C l 400 400 - 60 min T = 28 °C l 430 430 - 90 min T = 28 °C l 460 460 - 120 min T = 28 °C l 490 490 - Continuous T = 28 °C l/h 60 60 - Heating-up time T= 28°C min 289 289 -
T
= 10ºC / T
cold
30 min T = 45 °C l 249 249 - 60 min T = 45 °C l 268 268 - 90 min T = 45 °C l 286 286 - 120 min T = 45 °C l 305 305 - Continuous T = 45 °C l/h 37 37 - Heating-up time T= 45°C min 465 465 -
T
= 10ºC / T
cold
30 min T = 55 °C l 256 256 - 60 min T = 55 °C l 283 283 - 90 min = 55°C l 310 310 - 120 min T = 55 °C l 337 337 - Continuous T = 55°C l/h 54 54 - Heating-up time T= 55°C min 398 398 -
= 55ºC (Heatpump function only)
set
= 55ºC (Heatpump function only)
set
= 65ºC (Heatpump + electric element)
set
Shipping data
Empty weight kg 105 105 ­Weight including packaging kg 115 115 ­Maximum weight kg 390 390 ­Width packaging mm 765 765 ­Height packaging mm 1945 1945 ­Depth packaging mm 765 765 -
AHDS 290
Page 3
AH(D)(DS)
Installation diagrams
A Cold water B Hot water C Return circulation
1 Pressure reducing valve 4 Stop valve 5 Non return valve 6 Circulation pump 9 Drain valve 11 Isolating valve 12 Temperature gauge 13 Condensate drain 14 Hot water outlets 15 Expansion relief valve 16 Expansion vessel 17 Three-way valve 18 Hot water tank 19 Float valve
At this moment the AHDS for solar applications is being fi ne-tuned by our Engineering Department. For more information, please contact our Technical Support Group.
Vented
Unvented
Vented (AHDS)
Page 4
AH(D)(DS)
Electrical diagrams
AH(D)(DS)
A Controller B Fan C Compressor D Electric element E Magnet valve (short or long circuit) F Display (integrated in the control) G Temperature sensor (T5 - solar coil) H Temperature sensor (T6 - solar coil) J Temperature sensor (T7 top of the tank) K Temperature sensor (T8 bottom of the tank) L High pressure switch M Double pole mains switch
CONNECTIONS SOLAR CONTROLLERCOMPONENTS
1 - ­2 - ­3 N Magnet valve 4 L (short or long circuit) 5 L 6 N 7 L 8 N 9 L 10 N Power supply 11 12 L 13 N 25 - ­26 - ­27 - Temperature sensor 28 - (T5 - solar coil) 29 - Temperature sensor 30 - (T6 - solar coil) 31 - Temperature sensor 32 - (T7 top of the tank) 33 - Temperature sensor 34 - (T8 bottom of the tank) 35 - ­36 - ­37 ­38 -
Electric element
Compressor
1
Fan
High pressure switch
Dimensions
AH 290
AHD 290
A Total height 1815 1840 B Unit height 1790 1790 D Diameter unit 660 660
1 Diameter air-intake - 160
G G2 Diameter air outlet - 160 H Height-air intake / air outlet 1815 1840 Hx
1 x-position air intake - 190
Hx2 x-position air outlet - 480 Hy1 y-position air intake - 200 Hy2 y-position air outlet - 470 J Height air intake / air outlet - 55 M Height cold water inlet 110 110 N Height hot water outlet 1410 1410 P Height cleanout 45 650 T Height heat exchanger inlet - ­U Height heat exchanger outlet - ­V Height circulation connection 820 820 W Height condensate outlet 1345 1345 Z Height electric element 925 925 1 Cold water connection (male) R 1” R 1” 2 Hot water connection (male) R 1” R 1” 6 Clean out opening Ø 110 Ø 110 7 Condensate outlet (male) Ø 12 Ø 12 11 Electric element - ­14 Circulation connection (female) R 1” R 1”
On all AH(D)(DS) heatpumps a warranty of 5 years on the tank will apply and 1 year on all parts.
www.aosmithinternational.com
Data subject to change INT/0808/AH/02
Terms and conditions apply, please refer to our website.
Loading...