A.O. Smith ADMP - 50, ADMR - 90, ADMR - 40, ADMR - 115, ADMP - 115 User Manual

...
Innovation has a name.
ADMP / ADM / ADMR
Atmospheric commercial water heater
ADMP / ADM / ADMR - 40/50/60/80/90/115/135
An extensive range of atmospheric water heaters to suit most
larger hot water systems • Ef cient, automatic hot surface igniter
• Two access covers for comprehensive waterside tank maintenance
• External control connection • Voltage-free contact for general fault indication • Optional ancillaries: Unvented kits • Destrati cation pump kit • Powered anode • Flue fan kit • ADMP Permanent pilot ignition • Pilot proving kit available • ADM Electronic ignition
• Control, high limit and energy cut-off thermostats provide triple protection and ensure safe operation • ADMR Electronic ignition
• Flue damper to minimise standing losses • ThermoControl for easy and fl exible control / fault diagnosis • Programmable for
legionella purge cycle
ADMP / ADM / ADMR
Technical specications
ADM 40
ADM 50
ADM 60
ADM 80
ADM 90
ADM 115
ADM 135
ADMR 40
ADMR 50
ADMR 60
ADMR 80
ADMR 90
ADMR 115
Gas data natural gas 2H (G20)
Input* kW 42.2 56.5 66.4 82.5 98.3 126.6 143.4 42.2 56.5 66.4 82.5 98.3 126.6 143.4 Output kW 32.3 42.8 50.2 62.4 74.3 95.8 109.8 32.3 42.8 50.2 62.4 74.3 95.8 109.8 Inlet pressure mbar 20 20 20 20 20 20 20 20 20 20 20 20 20 20 Burner pressure mbar 8.5 8.5 8.5 8.5 8.5 8.5 11.3 8.5 8.5 8.5 8.5 8.5 8.5 11.3 Gas consumption** m
Diameter main orice mm 3.2 3.2 3.1 2.95 3.2 3.2 3.9 3.2 3.2 3.1 2.95 3.2 3.2 3.9
Max. flue gas temperature °C 180 200 200 180 180 200 185 180 200 200 180 180 200 185 Flue gas discharge kg/h 121.7 130.2 199.4 190.1 329.0 253.1 302.6 121.7 130.2 199.4 190.1 329.0 253.1 302.6
Gas data butane 3+ (G30)
Input* kW 41.6 55.3 68.2 80.7 96.1 123.5 138.4 41.6 55.3 68.2 80.7 96.1 123.5 138.4 Output kW 32.6 42.8 52.8 62.6 74.5 95.8 108.5 32.6 42.8 52.8 62.6 74.5 95.8 108.5 Inlet pressure mbar 30 30 30 30 30 30 30 30 30 30 30 30 30 30 Burner pressure mbar - - - - - - - - - - - - - ­Gas consumption** kg/h 3.0 4.0 5.0 5.9 7.0 9.0 10.1 3.0 4.0 5.0 5.9 7.0 9.0 10.1
Diameter main orice mm 1.7 1.7 1.7 1.5 1.7 1.7 2.25 1.7 1.7 1.7 1.5 1.7 1.7 2.25
Max. flue gas temperature °C 180 200 200 180 180 200 185 180 200 200 180 180 200 185 Flue gas discharge kg/h 125.9 129.4 183.9 205.3 344.9 255.6 319.6 125.9 129.4 183.9 205.3 344.9 255.6 319.6
Gas data propane 3+ (G31)
Input* kW 38.4 51.1 63.3 77.7 89.6 113.0 130.1 38.4 51.1 63.3 77.7 89.6 113.0 130.1 Output kW 30.0 39.5 48.9 60.1 69.2 87.4 101.7 30.0 39.5 48.9 60.1 69.2 87.4 101.7 Inlet pressure mbar 37 37 37 37 37 37 37 37 37 37 37 37 37 37 Burner pressure mbar - - - - - - - - - - - - - ­Gas consumption** kg/h 2.7 3.7 4.5 5.6 6.4 8.1 9.3 2.7 3.7 4.5 5.6 6.4 8.1 9.3
Diameter main orice mm 1.7 1.7 1.7 1.5 1.7 1.7 2.25 1.7 1.7 1.7 1.5 1.7 1.7 2.25
Max. flue gas temperature °C 180 200 200 180 180 200 185 180 200 200 180 180 200 185 Flue gas discharge kg/h 115.2 119.9 177.5 187.4 187.4 239.4 297.1 115.2 119.9 177.5 187.4 187.4 239.4 297.1
Draw-off capacity
Storage capacity l 309 357 298 335 278 253 252 309 357 298 335 278 253 252 Max. temperature setting °C 73 73 73 73 73 73 73 80 80 80 80 80 80 80 30 min. T=44°C l 621 766 767 914 957 1118 1240 621 766 767 914 957 1118 1240 60 min. T=44°C l 937 1183 1258 1524 1684 2054 2313 937 1183 1258 1524 1684 2054 2313 90 min. T=44°C l 1253 1601 1749 2134 2410 2990 3385 1253 1601 1749 2134 2410 2990 3385 120 min. T=44°C l 1568 2019 2240 2744 3137 3926 4458 1568 2019 2240 2744 3137 3926 4458 Continuous T=44°C l/h 631 836 982 1220 1453 1872 2145 631 836 982 1220 1453 1872 2145 Heating-up time T=44°C min. 29 26 18 16 11 8 7 29 26 18 16 11 8 7 30 min. T=50°C l 547 674 675 805 842 984 1092 547 674 675 805 842 984 1092 60 min. T=50°C l 824 1041 1107 1341 1482 1808 2035 824 1041 1107 1341 1482 1808 2035 90 min. T=50°C l 1102 1409 1539 1878 2121 2631 2979 1102 1409 1539 1878 2121 2631 2979 120 min. T=50°C l 1380 1777 1971 2415 2760 3455 3923 1380 1777 1971 2415 2760 3455 3923 Continuous T=50°C l/h 556 735 864 1073 1279 1647 1888 556 735 864 1073 1279 1647 1888 Heating-up time T=50°C min. 33 29 21 19 13 9 8 33 29 21 19 13 9 8 30 min. T=55°C l 497 612 614 732 766 895 992 497 612 614 732 766 895 992 60 min. T=55°C l 749 947 1006 1219 1347 1643 1850 749 947 1006 1219 1347 1643 1850 90 min. T=55°C l 1002 1281 1399 1707 1928 2392 2708 1002 1281 1399 1707 1928 2392 2708 120 min. T=55°C l 1255 1615 1792 2195 2509 3141 3566 1255 1615 1792 2195 2509 3141 3566 Continuous T=55°C l/h 505 669 785 976 1162 1497 1716 505 669 785 976 1162 1497 1716 Heating-up time T=55°C min. 37 32 23 21 14 10 9 37 32 23 21 14 10 9
Electrical data
Power consumption W 30 30 30 30 30 30 60 50 50 50 50 50 50 80 Power supply VAC/Hz 230 (-15 / +10%) / 50 230 (-15 / +10%) / 50 (+/- 1 Hz)
3
/h 4.0 5.4 6.3 7.9 9.4 12.1 13.7 4.0 5.4 6.3 7.9 9.4 12.1 13.7
ADMR 135
General
Anodes - 2 2 2 3 3 4 4 2 2 2 3 3 4 4 Maximum working pressure bar 8 8 Maximum weight kg 504 578 507 573 522 523 581 504 578 507 573 522 523 581
Shipping data
Weight empty kg 195 221 209 238 244 270 329 195 221 209 238 244 270 329 Weight incl. packaging kg 214 242 230 259 265 291 350 214 242 230 259 265 291 350 Width packaging mm 780 780 780 780 780 780 910 780 780 780 780 780 780 910 Height packaging mm 1930 2140 1930 2140 1975 2045 2050 1930 2140 1930 2140 1975 2045 2050 Depth packaging mm 870 870 870 870 870 870 910 870 870 870 870 870 870 910
* Gas data on gross value ** Gas consumption at 15°C and 1013.25 mbar
ADMP / ADM / ADMR
Dimensions ADM / ADMR
A 1900 2100 1900 2100 2000 2085 2085 B 1760 1960 1760 1960 1795 1870 1870 D 710 710 710 710 710 710 710 E 800 800 800 800 800 800 800 F 1100 1100 1100 1100 1105 1105 1105 G 150 150 180 180 225 225 225 H 660 660 660 660 675 675 675 J 1840 2040 1840 2040 1935 2010 2010 K 400 400 400 400 400 400 205 M 565 565 565 565 575 650 650 N 1605 1810 1605 1810 1640 1715 1715 P 730 730 730 730 740 825 855 R 500 515 500 515 525 600 595 S 1550 1760 1550 1760 1595 1660 1660
1 Cold water (external) R11/2 2 Hot water (internal) Rp11/2 3 Gas control (internal) Rp3/4 (ADM(R) 135 = Rp1) 4 Tank drain valve (internal) Rp1
1
/2 5 T&P valve (internal) 1-11.5 NPT (40-80) Rp1
1
/2 (90-135) 6 Cleaning and inspection opening Ø100
Dimensions in mm. All ADM and ADMR water heaters receive a three years warranty on the tank and one year on parts.
ADM(R) 40
ADM(R) 50
ADM(R) 60
ADM(R) 80
ADM(R) 90
ADM(R) 115
ADM(R) 135
1 Pressure reducing valve 3 T&P valve 4 Stop valve 5 Non-return valve 6 Circulation pump
7 Destrati cation pump
9 Drain valve 10 Gas cock 11 Isolating valve 12 Temperature gauge 14 Hot water outlets 15 Expansion relief valve 16 Expansion vessel 17 Three way valve 18 Water tank 19 Float valve
A Cold water B Hot water C Return circulation D Gas supply E Overfl ow pipe H Expansion vent pipe
A.O. Smith unvented system kits utilise combination valves.
An ADM/ADMP or ADMR water heater should be installed in accordance with local standards and ventilation require­ments (category B11BS).
Further installation and connection details can be found in the Installation & Commissioning Manual.
ADMP / ADM / ADMR
Installation diagrams ADM / ADMR
Vented
Unvented
ADMP / ADM / ADMR
Electrical diagram ADM
TERMINAL STRIP CONNECTIONS
Earth N Neutral L1 Phase input of controller L2 Phase input of flue gas thermostat L3 Phase output of flue gas thermostat
COMPONENTS
A Two-terminal main switch B Flue gas thermostat C Indicator LED “Error” D Indicator LED “Running” E “RESET” button F Burner control G Control thermostat H Frost thermostat J 0/1 switch of controller K Safety thermostat L High-limit thermostat M Extra error sensor N Gas control O Glow igniter P Ionisation rod
CONNECTIONS ON BURNER CONTROL
N1 Neutral Earth L’ Phase input of burner control L” Phase output to safety circuit and thermostat circuit TH Phase input of thermostat circuit GV1 Phase output to gas control MAX Phase input of safety thermostat LG Phase output to glow igniter I Ionisation signal detection NO “Normally open” port of the extra error sensor P Phase input of extra error sensor NC “Normally closed” port of the extra error sensor
F1 Fuse
ADMP / ADM / ADMR
Electrical diagram ADMR
TERMINAL STRIP CONNECTIONS
Earth N Neutral L1 Phase input of controller L2 Phase input of program­ controlled pump L3 Phase input of continuous pump L4 Phase input of extra error signal L5 Phase input of flue damper motor L6 Phase output of flue damper motor (feedback) L7 Phase input of isolating transformer (primary side) L8 Phase output of isolating transformer (secondary side)
COMPONENTS
A Controller B Gas control C Glow igniter D Ionisation rod E Extra error signal F Double-pole mains switch G Program-controlled pump H Continuous pump J Flue damper K Isolating transformer L I/0 switch control M Display/Flat cable N Extra ON mode switch O Connector for the flue gas sensor P Temperature sensor (T2 - bottom of tank) Q Temperature sensor (T1 - top of tank) R Selection resistor
CONTROLLER CONNECTIONS
J1 Connector for display to controller J2 Connector for power supply to controller J19 Connector for extra error signal and power supply to flue damper J20 Connector for gas control J21 Connector for program­ controlled pump J29 Connector for feedback from flue damper JP2 Connector for ionisation rod and glow igniter JP3 Connector for temperature sensor T2 JP4 Connector for flue gas sensor JP5 Connector for temperature sensor T1 JP6 Connector for selection resistor and feedback from micro-switch JP8 Connector for extra ON mode switch
F1 Fuse F2 Fuse
Data subject to change INT/0808/ADMR/01
Terms and conditions apply, please refer to our website.