The Filet Bun Steamer, producing a hot dry
steam, transforms room temperature buns into
hot moist buns lor the Filet-O-Fish™ sandwic h .
This is done on a electrically heated steam gen
erator. The buns are placed into the chamber
and steam flows around them. The steam is cre
ated from 3 measured amounts of water being
sprayed onto the steam generator surface.
WARNING
The steamer should be grounded
according to local electrical codes to
prevent the possibility of electrical
shock, it requires a grounded receptacle
with a separate electrical line, protected by
a fuse or circuit breaker of the proper rating.
Dimensions — Overall dimensions of the steame r a r e
8-1/16" (20.5 cm) high x 13-3/8" (34 cm) wide x 223/8" (57 cm) deep.
Approximate weight — Shipping weight of the unit is
50 pounds (22.5 Kg).
Hazard Communication Standard (HCS) — The
procedures in this chapter include the use of
chemical products. These chemical products
will be highlighted with bold face letters
followed by the abbreviation (HCS). See the
Hazard Communication Standard (HCS)
Manual for the appropriate Material Safety Data
Sheets) (MSDS),
1 0502811 Cover 1 Removable. Confines steam to the bun spatula
area.
2 0500315 Diffuser 1 Collects water condensation within the steam
generator. Gravity draws the water buildup back
down onto the steam generator surface,
4 2100118 Handle Guard 1 Reduces heal transfer to handle and acts as a
hand-guard.
5 2100119 Handle 1 Spatula hand-grip
6 0501555 Cover Pant- 1 Sheet metal part covering electrical controls.
7 20GK135 Solenoid Tube Kit 1 Conducts water from water solenoid valve to
steam generator surface.
8
0010572 Water Solenoid Valve 1 Electrically controlled ON/OFF valve for water.
9 001K504 Solid State Control 1 Controls solenoid opening/closing and overall
(120, 208, 220/240 VAC, 60 Hz) cycle time. Also turns on ready light and audio
001K504R Rebuilt Solid State Control: 1 signal for five seconds at end of cycle.
(120, 208, 220/240 VAC, 80 Hz) 001K505 Solid State Contra! 1 (220/240V, 50 Hz) 0G1K505R Rebuilt Solid Stale Control 1 1220/240V, 50 Hz)
10 402K181 Audio Signal Kit 1 Audio signals sounds when steam cycle has ended.
11 4010166 Start C ycle Button 1 Activates timer and initiates steaming cycle.
Mfg. Series 91Q03XX only *401K104 Start Cycle Button 1 Mfg. Series 90208XX only
PARTS IDENTIFICATION AUD FUNCTION
which holds buns while steaming,
ITEM PART NO. DESCRIPTION QTY.FUNCTION
12 1000904 Label, Control Panel 1 Identifies controls.
*1000829 Label, Control Panel 1
Mfg. Series 90208XX only
13 4010151 Power Switch (120 VAC) 1 Controls electrical po wer so the unit. Lights up
4010137 Power Switch (208, 220/240 VAC) 1
*401K103 Power Switch 1
*4010135 Power Switch (Germany) 1
14 406K323 Heater Indicator Light 1 Comes ON when heating element is heati ng.
*406K004 Heater Indicator Light 1 (208, 220/240 VAC) White
*406K001 Power-On Light 1 (120 VAC) Red
*406K002 Power-On Light 1 (208, 220/240 VAC) Red
15 4030206 Thermostat 1 Maintains and controls heat to steam generator.
16 219K001 Generator Tube Kit 1 Teflon tube which cond ucts water from brass
elbow to steam generator.
17 4010168 Transformer (120 VAC) 1 Reduces inco ming voltage.
4010169 Transformer (208, 220/240 VAC) 1
*4010145 Transformer (120 VAC) 1
*4010146 Transformer (208, 220/240 VAC) 1
18 210K104 Leg Kit (set 4) 1 Elevates unit to allow cooling air circulation.
(Includes 4 screws and 4 screw covers)
19 200K134 Inlet Tube Kit 1
200K196 Inlet Tube Kit 1 water solenoid valve.
20 0020719 Main Housing 1 Protective metal sides and creates a chassis for
She steam generator.
21 0020590 Base Plate 1 Bottom side of main housing.
22 0502171 Water Valve Bracket 1 Metal support used to secure water valve to
Steamer.
Mfg. Series 91003XX only
Mfg. Series 91003XX only
Mfg. Series 91003XX only
Mfg. Series 90208XX only
Mfg. Series 90208XX only
Mfg. Series 91003XX only
Mfg. Series 91003XX only
Mfg. Series 90208XX only
Mfg. Series 90208XX only
Mfg. Series 90208XX only
Mfg. Series 90208XX only
(365-395°F, 185-202°C)
Mfg. Series 91003XX only
Mfg Series 91003XX only
Mfg. Series 90308XX only
Mfg. Series 90208XX only
Mfg. Series 9100314 & 9100316 only
when power is ON.
Conducts water from quick disconnect body to
ITEM PART NO. DESCRIPTION QTY, FUNCTION
23 040K110 Insulation Kit 1 Reduces heat transfer to outside sheet metal.
24 0400258 Strain Relief 1 Holds power cord set to cabinet.
25 0700463 Power Cord (NEMA 5-15P) 9100312 1 Transfers electric power to the steamer.
0700451 Power Cord (NEMA 5-20P) 9100310 0700452 Power Cord (NEMA 6-20P) 9100314-9100316 0700453
International (CEE 7/7) 07004 37 Power Cord Assembly, Europe (Mennekes #ME316P6-1302)
(IEC 309, 16 Amp)
26 4060304 Terminal Block 1 Provides connection point for electrical wires.
27 0501973 Thermostat Bulb Retainer 1 Holds thermostat bulb against generator.
28 208K109 Quick Disconnect Body 1 Receptacle portion o! the water quick-disconnect,
attached to the rear of main housing.
29 403K162 High Limit Thermostat 1 Resettable saf ety switch which turns the power OFF
controlling maximum temperature.
*403K222 High Limit Thermostat 1 Safety switch which turns the power OFF to the entire
temperature {approx. 450*F/232°G).
30 0010503 Intel Hose Assembly (includes 1 Conducts wafer from pressure regulator to the
Items #32, 33, 34 & 35) steamer.
31 010K174 Steam Generator 1 Heated aluminum casting. When water is sprayed
(120 VAC) onto the surface, it turns info steam.
010K204 Steam Generator
(208, 220/240 VAC)
32 208K108 Quick Disconnect Insert 1 Attaches to quick disconnect body to allow
(Includes worm clamp) water to steamer.
33 217K108 Water Valve Kit (Consists of 1 Provides a means to shut OFF main water flow.
2 worm clamps & water valve)
34 203K108 Poly Braid Hose Kit (2 pieces) 1 Reinforced water line.
35 205K101 Tee Adapter Kit (Consists of a 1 Allows hookup of 2 inlet hose assemblies to
"Tee" lilting and 2 clamps) 1 water supply line.
36 209K106 Calibration Kit |FBS) 1 Used for water volume calibration.
(Consists of measuring cup and
24" (61 mm) teflon tube.)
37 0011090 Plate & Quick Disconnect Assy. 1 Receptacle portion of the water Quick-Disconnect,
* 0700492 Wire Set 1 Permits connection of all electrical parts.
0700351 Wire Set 1
Power Cord Assembly,
Mfg. Series 91003XXonly
Mfg. Series 90208XX only
Mfg. Series 9100314 & 9100316
(Japan)
Mfg. Series 91003XX only
Mfg. Series 90208XX only
to the Steam Generator when the thermostat is not
steamer when the thermostat is not controlling maximum
1 attached to the rear of main housing.
* NOT SHOWN
Loading...
+ 10 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.