Anton-Bauer Twin Two Position Charger User Manual

®
TWIN
SIMULTANEOUS
OWNER’S MANUAL
INTRODUCTION
The TWIN is a simultaneous Two Position charger for all Anton/Bauer® Gold Mount® Batteries. Its lightweight and small size makes it an ideal charger for travel. As a simultaneous charger each position operates independently allowing two batteries to charge at the same time (see battery charge times pg 5.).
The TWIN is fully compatible with all current and future Anton/Bauer Logic Series
®
batteries and delivers all the advancements and pro ven reliability of InterActive
charging.
®
Like all Anton/Bauer chargers, everything is automatic. Once a battery is placed on the TWIN, the charger will evaluate the battery and then execute the proper charge routine.
STANDARD FEATURES
Simultaneous Charging for all Anton/Bauer Logic Series bat teries.
Full InterActive technology including six simultaneous charge termination
systems, Balance and Rejuvenation modes, and LifeSaver
®
Maintenance mode.
Wide range mains input compatibility (90-250 VAC 50-60 Hz) automatically adapts
to any mains source worldwide.
Expanded InterActive communications with DIGITAL batteries, anticipating new
cell technologies.
Slim, ultra-lightweight design for easy portability.
This unit was packaged at the factory to arrive intact at its destination. If there is any damage to the packaging or the unit when received, please notify the carrier immediately.
SAFEGUARDS
Power Sources: This unit was designed to operate at mains voltages from
90 to 250 Volts AC, 50-60 Hz.
Risk of Electrical Shock: Refer servicing to qualified service personnel. Important: When powering charger using a generator, the generator must
produce a
sine wave or modified sine wave output, otherwise the charger may be damaged.
TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE.
1
GROUNDING/EARTHING
IMPORTANT WARNING: THIS APPARATUS MUST BE EARTHED.
To ensure safe operation, the three pin plug supplied must be inserted only into a standard three-pin power point that is effectively grounded through the normal household wiring. Extension cords used with the equipment must be three-conductor and be correctly wired to provide connection to earth ground. Improperly wired extension cords are a dangerous electrical hazard.
The fact that the equipment operates satisfactorily does not imply that the power point is properly grounded and that the installation is completely safe. If any doubt exists about the correct grounding of the power point, consult a qualified electrician.
IMPORTANT: The wires in this main lead are colored in accordance with the
following code:
Green and yellow Earth Blue Neutral Brown Live
OPERATION
Self-Test
Upon applying mains power, each TWIN will initiate a self-test mode. This mode is indicated by the LED’s on the unit. Each positio n will light the red LED followed by the green LED. Upon completion of the self-test, the green status light will light steadily, indicating that the unit is ready for operation.
Charging
As with all Anton/Bauer chargers, charging with TWIN is fully automatic. Mount any applicable battery to any open Gold Mount position on the charger and it will automatically determine the appropriate charge routine and execute it.
IMPORTANT: In order to ensure correct operation when charging the Titan Twin
should be positioned with cooling vents vertical as shown in the Figure on page 1.
Applications
The TWIN models will charge any combination of Anton/Bauer Logic Series Gold Mount batteries including models: ProPac
®
ProFormer Dionic and InterActive 2000
, Digital ProPac 13/14, Digital Compac 13/14, Digital Trimpac 13/14,
HyTRON™ batteries.
Each TWIN incorporates the exclusive Anton/Bauer InterActive communication between battery and charger, which allows the charger to identify any Anton/Bauer battery attached and determine the precise charge routine for that battery under the prevailing conditions.
®
13/14, Compac® 13/14, Trimpac® 13/14,
2