Anton-Bauer HyTRON 140, HyTron 100, HyTRON 50 User Manual

4 (1)
Anton-Bauer HyTRON 140, HyTron 100, HyTRON 50 User Manual

®

BATTERY SYSTEM

HyTRON140

HyTRON100

HyTRON50

OWNER’S MANUAL

TABLE OF CONTENTS

 

IMPORTANT ....................................................................................

2

INTRODUCTION..............................................................................

3

FEATURES ......................................................................................

4

HIGH VOLTAGE DESIGN ...............................................................

5

CHARGING WITH LOGIC SERIES® INTERACTIVE®

 

CHARGERS .....................................................................................

7

OVER-DISCHARGED BATTERIES ................................................

8

LIQUID CRYSTAL DISPLAY (LCD)...........................................

8

RealTime® DISPLAY INDICATIONS.........................................

10

PREVENTATIVE MAINTENANCE ................................................

11

GUIDELINES FOR OPTIMUM PERFORMANCE AND

 

MAXIMUM LIFE..............................................................................

12

SERVICE........................................................................................

15

SPECIFICATIONS .........................................................................

15

Warranty - InterActive 2000™ HyTRON™ Battery......................

15

IMPORTANT

The InterActive 2000 HyTRON battery represents the latest in video battery technology. Nickel Metal Hydride (NiMH) is similar to NiCad batteries in most characteristics. However, NiMH has more sensitive charging and discharging parameters and requires a longer charge time for optimum performance. The charge time is approximately 2-6 hours, depending on battery and charger combination.

Hytron batteries are specifically designed to be charged with current

InterActive or InterActive 2000 chargers with SOFTWARE

REVISION 3.4 OR HIGHER. Old model Interactive

MP4D Quad, Lifesaver Dual, ABC800 cannot charge these batteries.

DO NOT attempt to charge on any charger not manufactured by Anton/Bauer. Contact the Anton/Bauer® Customer Support Group at (203) 925-4991 if any questions of applicability exist.

1

INTRODUCTION

The development of the new InterActive 2000 HyTRON battery system has been made possible by recent advancements in a cell technology originally designed for the mobile computing industry. These nickel metal hydride cells provide the highest energy density cell available. The high performance of the new batteries is assured through the incorporation of the pioneering InterActive technology of the Anton/Bauer Digital system. Each battery is equipped with an on board “fuel computer” which monitors energy put into and taken out of each HyTRON battery, as well as critical operating characteristics and conditions. This data is communicated to the InterActive charger to ensure safe and optimize reliable performance.

In addition, remaining battery capacity information is available to the operator by means of an LCD display on each battery and in the viewfinder of the most popular broadcast and professional camcorders. The patented interface from the Digital battery to the camera viewfinder is factory standard equipment in over 30 camera/camcorder models from five leading manufacturers.

HyTRON is compatible with existing Anton/Bauer Logic Series InterActive chargers already in the field, as well as the InterActive 2000 PowerCharger line. Anton/Bauer Logic Series InterActive chargers were designed in anticipation of new cell technologies, so chargers in the field require only a single chip update to effectively address this new battery system, as well as the standard ProPac® and TrimPac® battery products. This upward and downward compatibility uniquely allows Anton/Bauer to introduce new high performance cell technology seamlessly into existing battery inventories. The new HyTRON battery will automatically identify itself to the InterActive charger, activating the specialized charge routines necessary to effectively utilize this new technology.

2

FEATURES

1.Microprocessor Fuel Computer - Accurately monitors the energy put into and taken out of the battery. This data is processed with sophisticated programs that take into account battery age, self discharge, charge/discharge rate, cell imbalance and previously experienced charge/discharge cycles. The HyTRON battery constantly “learns” its precise state of charge and remaining capacity. This data is automatically transmitted to an InterActive charger.

2.Integral ‘LCD’ - Accurately displays the percentage of remaining battery capacity at all times.

3.Viewfinder Fuel Gauge Display - The HyTRON battery was developed in cooperation with all the major equipment manufacturers including Sony, Ikegami, Panasonic, JVC, BTS, and Hitachi. Virtually all new cameras and camcorders available feature Anton/Bauer compatible InterActive systems that connect with the HyTRON battery “Fuel Computer” and display an accurate “Fuel Gauge” of remaining battery capacity in the viewfinder. Reference your camera/camcorders owners’ manual for proper menu settings.

4.Battery Management Data - the built-in two level LCD in the Logic Series InterActive PowerChargers provides access to vital performance and historical data such as present available battery capacity, calibrated battery capacity, battery serial number, date of manufacture, and number of charge/discharge cycles. This data, which is vital to creating an effective battery management and maintenance program, can also be automatically accessed with a printer when using a PowerCharger or MP4-D.

5.High Voltage Design - The 14.4 volt design of the HyTRON battery complies precisely with equipment manufacturers’ specifications, eliminating all the problems that cripple 12 volt batteries.

3

6.Impac® Case design - The computer designed high impact case eliminates conventional stress points. This feature protects the cells from impact that would damage or destroy conventional batteries.

7.Gold Mount® Interface - The solid metal mounting studs assure a smooth, precise mounting for the life of the battery. The Logic Series connector assembly features multiple gold plated, self aligning contacts and is compatible with all existing Anton/Bauer camera mounts and accessories.

8.Individual Computer Testing - Like all professional Anton/Bauer batteries, the InterActive 2000 HyTRON battery has been individually computer tested. For assurance of optimum capacity, voltage and overall quality, a computer print-out is enclosed.