Thank you for choosing Air Guard. Please read the following safety information carefully
before operating the machine. This information includes important safeguards about
installation, usage, and maintenance. Pay attention to all warning labels and instructions
in this manual and printed on the machine.
l Keep this device dry.
l Always connect to a grounded circuit to avoid risk of electrocution.
l Before connecting the machine to power, always check the voltage indicate on the machine
matches to your local AC voltage. Do not use the machine if AC power voltage does not match.
l Disconnect the machine from AC power before servicing and when not in use.
l If the supply cord is damaged, contact your local dealer for replacement.
l This product is for indoor use only! Do not expose to rain or moisture. If fluid is spilled,
disconnect AC power and clean with a damp cloth. If fluid is spilled onto electronic parts,
immediately unplug the machine and contact your local dealer for advice.
l No user serviceable and modifiable parts inside. Never try to repair this product, an
unauthorized technician may lead the machine to damage or malfunction.
l For adult use only. Children being supervised not to play with the machine. Never leave the
machine running unattended.
l The machine is not to be used by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge.
l Installed in a well ventilated area. Provide at least 50 cm space around the machine.
l Never add flammable liquid of any kind to the machine.
l Make sure there are no flammable materials close to the machine while operating.
l Only use Air Guard Antibacterial Solution. Other solution may lead to heater clog and
malfunction.
l If the machine fails to work, unplug the machine and stop operation immediately. Contact
your local dealer for advice.
l Before transporting the machine, make sure the fluid tank is completely drained.
3
l Air Guard Antibacterial Solution may present health risks if swallowed. Do not drink Air Guard
L 728 mm
W 428 mm
H 719 mm
solution. Store it securely. In case of eye contact or if solution is swallowed immediately look
for medical advice.
Unpacking and Inspection
Immediately upon receiving the antibacterial vaporizer, carefully unpack the carton, check the
content to ensure that all parts are present and have been received in good condition. If any parts
appear damaged or mishandled from shipping, notify the shipper immediately and retain the
packing material for inspection.
What is included: 1 x AG-3000 Antibacterial Vaporizer
2 x Power Cord (One for Fog Machine, the other for Fan)
2 x Fluid Tank
1 x User Manual
Product Dimensions
4
Product Overview
Breaker / Fuse
XLR 3-Pin / XLR 5-Pin DMX Connector
Neutrik PowerCon
Power Switch
Tank Capacity:5 liters
LCD control panel
Fog Output Nozzle
Multi-angle Fan
9 Positions are Available
5
Setting Up
Button
Function
[MENU]
Scroll through setting menu
[UP]/[TIMER]
[DOWN]/[VOLUME]
Up/Activate Timer fucntion
Down/Activate Volume function
[STOP]
Deactivate Timer/ Volume function.
Or to select and memorize the setting.
Hold 3 seconds to start self-cleaning process and shut down the machine
[MENU]
Scroll through setting menu
AG-3000
High / Low Output Mode
Step 1: Place the machine on a flat surface and in a suitably large area with at least 50 cm open
space at each side of the machine and 2 meters for the output direction of the machine.
Step 2: Fill the fluid tank with Air Guard fluid.
Step 3: Connect the machine to suitably rated power supply. To determine the power requirement
for the machine refer to the label on the back of the machine.
Always connect the machine to a protected circuit and ensure it is properly
grounded to avoid risk of electrocution.
Step 4: Turn on the machine by connecting the power cord. Heat-up takes approximatley 8 minutes.
Once the machine has reached operating temperature, the LCD screen will display “Ready To Fog”.
Now the machine is ready for operation.
Step 5: To start making fog, press the VOLUME button on the control panel.
Step 6: To turn off the machine, hold the STOP button for 3 seconds; the machine will automatically
run a self-cleaning process and shut down after the self-cleaning process is done.
Control Panel Operation
The machine can be operated with the onboard digital control interface.
6
Control Menu
Timer Duration
XXX Sec
Timer Output
XXX %
Fan Speed
XXX %
DMX-512
Address: XXX
Run Last Setting
XX
Air Pump Sensor
XX
Operation Mode
XXXX
Volume Output
XXX %
Timer Interval
XXX Sec
Select High Output or Low Output Mode
Set interval time at Timer mode from 1 to 300 seconds
Interval can be turned OFF. When “OFF” is selected, there is no interval time.
Once the duration time is up, machine stops fogging automatically.
Set duration time at Timer mode from 1 to 300 seconds
Set output volume at Timer mode
When machine is in Low Output mode, the volume can be set from 1 to
100%. When machine is in High Output mode, the volume can be
set from 20 to 100%
Set output volume at Volume mode
When machine is in Low Output mode, the volume can be set from 1 to
100%. When machine is in High Output mode, the volume can be
set from 20 to 100%, or set at continuous output
Set fan speed from 20 to 100% or to turn off Fan
Set DMX address from 1 to 510
Turn On/Off Air P ump Se nsor
Turn On/Off run last setting function
7
DMX Connector Pin Assignment
Pin
Function
1
Ground
2
Data-
3
Data+
4
N/A
5
N/A
Channel
Value
Function
1
0-127
LowOutputMode
128-255
HighOutputMode
2
0-5
OutputOff
6-255
Output21-100%
3
0-5
Fan speed at 20%
6-255
Fan speed 21-100%
The machine provides a 3- or 5-pin XLR connector for DMX connection. The diagram below indicates
pin assignment information.
DMX Operation
Making the DMX Connection – Connect the machine to a DMX controller or to one of the machines
in the DMX chain. The machine uses a 3-pin or 5-pin XLR connector for DMX connection, the
connector is located on the front of the machine.
Address Setup – Use control menu to set DMX address. The machine occupies 3 control channels.
The starting address is defined as the first channel from which the machine will respond to the
controller. Always double check to make sure there are no overlapping channles in order to control
the machine correctly.
DMX Channel Function
8
Fluid
Use Air Guard FLD / FLV Antibacterial Solution for AG-3000.
The machine is tested and calibrated with this fluid to
achieve the best output performance. Warranty will be
voided if any other type of liquid is used, improper use of
liquid may lead to machine failure and malfunction.
Service and Maintenance
․ Do not allow the machine and fluid to become contaminated.
․ Regularly fill distilled water to fluid tank and run the machine to clean the system. After
cleaning, refill Air Guard fluids into fluid tank and make sure machine can produce fog
properly.
․ It is recommended to run the machine on a monthly basis in order to achieve best
performance and output condition.
․ Excessive dust, liquid and dirt built up will degrade performance and cause overheating.
Breaker Reset
Disconnect AC power before resetting the breaker. Only replace fuse with same type