RESPONSIBLE ADULT SUPERVISION. This
pro du ct is de si gn ed to a id in th e m on ito ri ng
of yo ur child . Wh en using th e moni to r, you
must still provide the super vision necessary
for the continued safety of your child.
Monitoring of premature babies, or those
considered to be at risk, should always
be carried out under the supervision of
a health professional. This monitor is not
intended to be used as a medical monitor.
Strangulation Hazard—Children have
2.
STRANGLED in cords. Keep adapter cords
out of the reach of children (more than 3
feet (1m) away) NEVER attempt to use
of Sensor Pad if protective covering is
damaged or broken.
3. Never use extension cords with AC
adapters. ONLY use the AC adapters
provided.
4. When an AC Adapter is plugged into
an electrical outlet, DO NOT touch the
exposed end.
5. ALWAYS be sure that both the
transmitter and receiver are working
properly and are within range of each
other. Test monitor before first use,
periodically and when changing location
of the Nursery Unit.
6. ALWAYS be sure to immediately check
on baby whenever an alarm sounds.
DO NOT use monitor near water (such
7.
as bath tub, sink, etc.).
RISK OF ELECTRIC SHOCK
DO NOT EXPOSE TO RAIN OR MOISTURE
Sensor Pad without
the protective cord
covering. Check
protective cord
covering before each
use to ensure it is
securely placed
under the leg of the
crib. Discontinue use
CAUTION
DO NOT OPEN
E
N
8. Keep monitor AWAY from heat sources
(such as stoves, radiators, etc.).
9. ALWAYS place both the Nursery Unit and
Parent Unit on a flat surface in an upright
position and allow for proper ventilation.
DO NOT place on sofas, cushions, beds,
etc. which may block ventilation.
10. This monitor uses public airwaves to
transmit signals. The Parent Unit may
pick up signals or interference from
other nursery monitors in your area. Your
monitor may even be picked up by other
households. To protect your privacy, make
sure both units are turned OFF when not in
use. If you experience interference, change
the channel on both units.
11. This product is NOT a toy. DO NOT allow
children to play with it.
12. This product contains small parts. Adult
assembly required. Exercise care when
unpacking and assembling the product
and keep small parts away from children.
13. When using the monitor, the room
temperature should be between 50°F
(10°C) and 104°F (40°C).
BATTERY WARNING
14. Use ONLY AAA RECHARGEABLE
batteries for the Parent Unit. DO NOT
mix old and new batteries. DO NOT
mix alkaline, standard or rechargeable
batteries. Insert batteries with correct
polarity. DO NOT short-circuit supply
terminals. ONLY use the recommended
batteries or equivalent (volts and size)
and the correct adapter. Remove batteries
when product is stored for long periods
of time or when batteries are exhausted.
Dispose exhausted batteries properly. DO
NOT recharge non-rechargeable batteries.
Rechargeable batteries are ONLY to be
charged under adult supervision. Keep all
batteries away from children.
instructions should be read before the
product is operated.
15.2 Keep these instructions. The safety
and operating instructions should be
retained for future reference.
15.3 Heed all warnings – All warnings on the
product and in the operating instructions
should be adhered to.
15.4 Follow all instructions – All operating
and use instructions should be followed.
15.5 Water and moisture - DO NOT use
this apparatus near water. For example,
near a bath tub, wash bowl, kitchen sink,
laundry tub, in a wet environment or near a
swimming pool and the like. Care should be
taken so that objects do not fall onto units
and that liquids are not spilled into either
unit or Sensor Pad through its openings.
15.6 Cleaning - Disconnect all units before
cleaning. DO NOT immerse in water any
part of the Nursery Unit, Parent Unit, or
Charging Cradle. Clean only with dry cloth.
DO NOT spray with cleaning products or
solvents. Wipe Sensor Pad with a cloth
moistened very slightly with an antiseptic
or mild detergent.
15.7 Ventilation - DO NOT block any
ventilation openings. Allow for proper
ventilation when units are in use. DO NOT
cover the Nursery Unit or Parent Unit with
any object such as a blanket. DO NOT place
it in a drawer or in any location which
would muffle the sound or interfere with
the normal flow of air.
15.8 Heat sources - DO NOT install near
any heat sources such as radiators, heat
registers, stoves, TVs or other apparatus
(including amplifiers) that produce heat.
Heat can damage the case or electrical
parts.
15.9 Power cord protection - Protect the
Sensor Pad cord and Adapter’s power
cord from being walked on or pinched by
furniture or other items – Power supply
co rd s sh ould b e r ou ted so th at th ey are no t
likely to b e wa lked on or pin ch ed by items
upon or against them, paying particular
attention to cords and plugs, convenience
receptacle, and the point where they exit
from the product.
15.10 Accessories - Only use attachments/
accessories specified by the manufacturer.
DO NOT place this product on an unstable
cart, stand, tripod, bracket or table. The
product may fall, causing serious injury
to a child or adult and serious damage to
the product. Use ONLY with a cart, stand,
tripod, bracket or table recommended by
the manufacturer or sold with the product.
Any mounting of the product should follow
the manufacturer’s instructions.
15.11 Unplug this appliance during lightning
storms or when not used for long periods
of time.
15.12 Servicing - DO NOT attempt to
service this product yourself as opening
or removing covers (except battery covers)
may expose you to dangerous voltage or
other hazards.
15.13 Replacement parts - When
replacement parts are required, be sure
the replacement parts specified by the
manufacturer have the same characteristic
as the original part. Unauthorized
substitution may result in fire, electric
shock or other hazards.
15.14 Usage - This baby monitor is
in ten de d as an aid . It is NOT a su bst it ute fo r
responsible and proper adult supervision
and should not be used as such. Use this
appliance ONLY for its intended use as
described in this manual.
15.15 Power Sources - Operate this
product only from the type of power
source indicated on the type plate of the
adaptor. If you are unsure of the type of
power supply to your home, consult your
dealer or local power company.
15.16 Overloading - DO NOT overload
wall outlets, extension cords or integral
convenience receptacles as this can result
in a risk of fire or electric shock.
15.17 Object and Liquid Entry - NEVER
push objects of any kind into this product
through casing slots as they may touch
dangerous voltage points or short out
parts that could result in a risk of fire or
electric shock. NEVER spill liquid of any
kind on the product.
15.18 Antenna - The antenna used for this
transmitter must be installed to provide
a separation distance of at least 7.9” (20
cm) from all persons and must not be
collocated or operating in conjunction with
any other antenna or transmitter.
15.19 Power Lines - An outside antenna
system should NOT be located in the
vicinity of overhead power lines or other
electric light or power circuit, or where it
can fall into such power lines or circuits as
contact with them may be fatal.
Strangulation Hazard—Children
15.20
have STRANGLED in cords. Keep adapter
cords out of the reach of children (more
securely placed under the leg of the crib.
Discontinue use of Sensor Pad if protective
covering is damaged or broken.
15.21 I n t er f e re n c e - T h is m o n it o r u s e s p u b l ic
airwaves to transmit signals. The Parent
Unit may pick up signals or interference
from other nursery monitors in your area.
Your monitor may even be picked up by
other households. To protect your privacy,
ma ke sure b ot h u nit s a re tur ned OF F w hen
not in use. If you experience interference,
change the channel on both units.
15.22 Vibration Source - When the monitor
is in use, DO NOT use a crib mobile or
other crib accessories that may produce
vibrations. Other sources of vibrations
may include fans, washing machines, loud
music, etc. These sources of vibration may
interfere with the performance of your
Angelcare
not sound if it continues to detect any
movement other than your baby’s. Be sure
all vibration sources are eliminated before
using the monitor.
You may experience false alarms for several
reasons. The most common reason is the
Nursery Unit has not been turned OFF after
you have removed your baby from the crib.
Another reason is the Sensor Pad has not
been placed under the mattress properly.
Be sure the Sensor Pad is on a flat, firm
surface with the printed side facing up.
The sensitivity level may also need to be
adjusted. Refer to step 5.1. Always be sure
to immediately check on baby whenever
an alarm sounds.
15.23 Sensor Pad - If the crib has a
spring or slat base, place a hard board
between the crib base and the Sensor
Pad measuring at least 13” x 13” (33 x 33
cm) and 1/4 inch (6 mm) thick. Only use
®
than 3 feet (1m) away)
NEVER attempt to use
Sensor Pad without the
protective cord
covering. Check
protective cord
covering before each
use to ensure it is
monitor and the alarm will
®
your Angelcare
sleeping environment such as a crib where
the Sensor Pad can rest on a completely
flat, firm surface.
16. IMPORTANT SAFETY INSTRUCTIONS
RELATED TO USE OF BATTERIES
16.1 Use ONLY the type and size of
batteries specified in the owner’s manual.
There is a risk of explosion if batteries are
replaced with an incorrect type.
16.2 Use ONLY AAA rechargeable
batteries and/or the AC Adapters provided
for the Parent Unit. You must use only
rechargeable batteries in the Parent Unit.
DO NOT use alkaline batteries or you will
severely damage the unit.
16.3 Charge the batteries for 15 hours prior
to first use . Be sure to have the monitor in
the OFF position during this period. ONLY
use the AC Adapters included with your
monitor.
16.4 DO NOT use these adapters with any
other equipments.
16.5 When unplugging the AC Adapter
from the Nursery Unit, be sure it is switched
to the OFF position. If it isn’t, the unit
will revert to battery mode if batteries
are installed.
16.6 DO NOT use rechargeable batteries
in the Nursery Unit. Use alkaline batteries
ONLY.
16.7 DO NOT dispose batteries in fire. They
may explode. Check with local regulations
for possible special disposal instructions.
16.8 Exercise care in handling batteries
in order not to short out the batteries
with conducting materials such as rings,
bracelets and keys. Overcharging, short
circuiting, reverse charging, mutilation, or
incineration of batteries must be avoided
to prevent one or more of the following
occurrences: release of toxic materials,
release of hydrogen and/or oxygen gas,
rise in surface temperature.
16.9 DO NOT attempt to recharge batteries
provided with or identified for use with
this product that are not intended to be
charged. The batteries may leak corrosive
electrolyte or explode.
16.10 DO NOT attempt to rejuvenate the
batteries provided with or identified for
use with this product by heating them.
Sudden release of battery electrolyte may
occur, causing burns or irritation to eyes
or skin.
16.11 If and when necessary, the batteries
must be replaced with identical new ones
or equivalent (volts and size). If a battery
to be replaced is connected with other
batteries in series, replace the other
batteries at the same time as well. DO
NOT mix old and new batteries.
16.12 Reverse polarity installation of the
batteries in the end product must be
avoided. Reverse insertion of batteries
can cause charging, and that may result
in leakage or explosion.
16.13 Remove batteries from this product
if you store the product over 30 days
because the batteries could leak and
damage the product.
16.14 Discard ‘dead’ batteries as soon as
possible since ‘dead’ batteries are more
likely to leak in a product. If a battery has
leaked or vented, it should be replaced
immediately using protective gloves.
16.15 DO NOT store this product, or the
batteries provided with or identified for
use with this product, in high-temperature
areas.
WARNING
(North America Only)
17.1 Modifications not authorized by the man-
ufacturer may void users authority to operate this device.
17.2NOTE: This equipment has been
tested and found to comply with Part 15
of the FCC Rules and the Industry Canada
licence-exempt RSS standard(s). These
limits are designed to provide reasonable
protection against harmful interference in
a residential installation. This equipment
generates, uses and can radiate radio
frequency energy and, if not installed and
used in accordance with the instructions,
may cause harmful interference to radio
communications.
17.3 However, there is no guarantee that
interference will not occur in a particular
installation. If this equipment does cause
harmful interference to radio or television
reception, which can be determined by
turning the equipment OFF and ON,
the user is encouraged to try to correct
the interference by one or more of the
following measures:
• Reorient or relocate the receiving
antenna.
• Increase the separation between
the equipment and receiver.
• Connect the equipment into an
outlet on a circuit different from that
to which the receiver is connected.
• Consult the dealer or an experienced
radio/TV technician for help.
17.4 This device complies with part 15 of
the FCC Rules and the Industry Canada
licence-exempt RSS standard(s). Operation
is su jec te d to t he fol ow ing tw o c on ditio ns:
1) This device may not cause harmful
interference, and
2) This device must accept any
interference received, including
interference that may cause undesired
operation.
FCC AND IC REGULATIONS
RF radiation exposure statement
The Nursery Unit complies with FCC RF radiation exposure limits set forth for an
uncontrolled environment. Caution: To maintain the compliance with the FCC's RF
exposure guideline, install the Nursery Unit at least 20cm from nearby baby and persons.
For body worn operation, this Parent Unit has been tested and meets the FCC RF exposure
guidelines. Use the supplied belt clip only. Use of other accessories may not ensure
compliance with FCC RF exposure guidelines.
Industry Canada
This product meets the applicable Industry Canada technical specifications.
CAN ICES-3 (B)/NMB-3(B)
One hardboard (not included)
Thickness: 1/4’ (’6 mm)
Minimum dimensions:
13’’ (33 cm) x 13’’ (33 cm)
Maximum dimensions:
equal to the mattress size
Hardboard
IMPORTANT
The hardboard must be larger
than the Sensor Pad(s) surface area.
BABY’S ROOM:
IMPORTANT
Place the crib near a supporting wall and far from air currents.
Install the Nursery Unit on a flat, stable surface facing the crib
at a distance of at least 3 feet (1 meter).
Cord cover 4:
Contains double sided
tape to securely install
beneath crib leg
Cord cover5:
Position vertically
between mattress
support and floor
Cord cover6:
Place under
the mattress
WARNING
STRANGULATION HAZARD.
Children have been STRANGLED by cords.
• Keep the AC adapter cord out of reach of children
(more than 3 feet away (1m).
• Do not put the Nursery Unit inside a crib or play yard.
• Because of the serious strangulation risk to infants and toddlers, parents and
caregivers should never place the nursery unit within 3 feet (1m) of a crib.
• NEVER use sensor pad without the cord covers. Check cord covers before each use
to ensure it is securely placed under the leg of the crib. Discontinue use of Sensor
Pad if any cord covers are damaged or broken.
• NEVER use extension cords with AC adapters. ONLY use the AC adapters provided.
This product is not a toy. Never allow children to play with it.
2.1 - SELECT A LOCATION FOR THE NURSERY UNIT
Select a location for the Nursery Unit that is
at least 36 inches (1 m) away from the crib.
2.2 SELECT THE CRIB LEG YOU WILL BE USING TO SECURE THE CORD COVERS
RECOMMENDED
1) Use the crib leg by the wall closest to the Nursery unit (fig 1). In cases where
6
5
4
3
Fig 1
2
1
the Nursery Unit is across the room, use
the leg closest to the Nursery Unit to
position the covered wire (fig 2). It is
always preferable that the covered cord
run along a wall.
OR
6
5
4
3
2
1
2.3 - INSTALL THE SENSOR PAD ON THE MATTRESS SUPPORT
3
Fig 2
1) Remove the mattress from the crib.
5
6
4
3
2
1
2) Place the Sensor Pad - printed side up
- on top of the hardboard at the center
of the crib.
3) Run the connection pin, warning label
and the first 5 cord covers down along
the backside’s of the crib leg, between
the mattress support and the inside
edge of the crib.
4
5
4) Bring the first 4 cord covers down
the floor, and keep the 5
fth
cord cover
vertically, along the backside of the crib
leg, (between the mattress and the
7) Snap together the remaining cord
covers that will run along the floor.
8) Remove any cord slack to make sure
no parts of the cord are loose.
9) Peel off the double-sided tape on the
th
cord cover and place it securely
4
under the crib leg.
10) Install the Nursery Unit on a flat, stable
surface facing the crib at a distance of
at least 36” and plug the Sensor Pad
cord into the Nursery Unit.
11) Check to make sure the Sensor Pad has
not moved from position.
12) Place the mattress back inside the crib.
The Sensor Pad functions with any size
and type of mattress except memory-foam
mattresses and hollow frame mattresses.
The hardboard maintains a constant
pressure on the Sensor Pad, enabling it to
detect the baby’s movements even when
the baby is at the edges of the crib.
WARNING
IMPORTANT
STRANGULATION HAZARD
• Remove all slack from Sensor Pad Cord.
• When lowering the mattress support
as your child grows, slide the vertical
Cord Cover (5) upward so it remains
approximately in the center between
the mattress support and the floor. Slide
the Sensor Pad Cord through the Floor
Cover to eliminate any additional slack.
2) Push and hold the Nursery Unit
left ‘wing’ button for 2 seconds.
The LCD monitor has 30 seconds
timeout to go to power saving
mode (dimmer illumination).
Press any keys to wake up.
E
N
When the Parent Unit is turned
ON and the Nursery Unit is OFF,
the Parent Unit will be searching
for connection with the Nursery
Unit. The Connection icon will scan
as the following cycle.
IMPORTANT ICONS
Temperature icon:
Indicates room temperature
Battery Level icon:
Indicates battery level
Empty
1/3 Full
2/3 Full
Full
Settings Icons: Access to settings
VOX icon: Indicates Vox function
is active (Voice activation)
ECO icon: Indicates ECO function
is active
Temperature Alarm icon: Indicates
Temperature Alarm is active
If there is a lost connection
between the 2 units
(refer to troubleshooting p.23):
• The Out-of-Range icon
will appear on the screen and
the Parent Unit will beep.
Sound icon: Indicates sound
is active
Sensor Pad icon: Indicates
the Movement Sensor is active
Pendulum icon: Indicates
the ‘TIC’ function is active
Level Bar: Indicates sound level
from Nursery Unit.
Connection icon: Indicates
the connection quality between
the Parent Unit and Nursery Unit.
monitor can be used with the pre-program factory settings
or you can also customise your settings to your preference.
NOTE: All changes
and adjustments made
in the settings mode will
not be activated unless
you confirm them by
pressing the Return icon.
A long beep will confirm
your modification.
5.1 - SENSOR PAD
TO ACTIVATE THE SENSOR PAD:
1
TO TEST THE SENSOR PAD:
12
IMPORTANT
When in settings mode, sound
transmission between Parent and
Nursery Units will be temporarily
deactivated. ONLY the movement
alarm will remain active
(if function is activated).
1) Press Sensor Pad icon to activate
or deactivate movement mode.
ONOFF
When the movement mode is OFF
the ‘TIC’ mode is automatically set OFF.
This allows you to detect the baby’s
sounds ONLY.
1) Move your hand lightly on the mattress.
2) Remove your hand from the mattress.
After 15 seconds you will hear a
‘TIC’ pre-alarm sound, and 5 seconds
later the Movement Alarm will trigger.
3) Repeat by moving your hand lightly
in all four corners of the mattress.
Ensure the Nursery Unit Movement
Indicator is still flashing.
MOVEMENT ALARM
• Alarm activates when no movement is detected by Sensor Pad for 20 seconds.
• Both the Parent Unit and Nursery Unit speakers will emit loud warning sound.
• Movement Alarm icon will show on the LCD screen.
IF THE ALARM DOES NOT SOUND
• Avoid contact with crib while Sensor Pad is in operation.
the Parent Unit to choose the desired
sensitivity level (1 to 5) OR press the
movement sensitivity icon
to choose the desired sensitivity level.
L1 being the least sensitive and L5 the
Level 1
Level 2
Level 3
3
Level 4
Level 5
TO ACTIVATE THE TIC FUNCTION:
most sensitive.
4) Press Return icon to confirm your choice
and return to normal screen.
NOTE:
If you are receiving false alarms,
adjust the sensitivity level.
NOTE:
Whilst in Setting mode, if after 30 seconds
no adjustments are made, the unit will go back
to normal and no update will be done.
This allows you to hear a ‘TIC’ sound with baby’s movements
(when the movement detection is ON)
1
NOTE:
When the Movement Mode
is set to OFF, the TIC Mode
is automatically set to OFF.
1) Press TIC icon to activate
or deactivate the ‘TIC’ function.
ONOFF
If the TIC icon is activated a regular TIC
sound will emit from Parent Unit.
IMPORTANT
• The Sensor Pad is not designed for use with adults, children or infants older
than 24 months.
• Once you are finished using the Sensor Pad, please remove it from the baby’s
crib and store it away.
At level L0 the level bar will still appear on
the screen and the icon will blink. If you press
the blinking sound icon again, it automatically
activates the Mute function. The Bar will disappear
and a cross will appear in the icon screen. To
DEACTIVATE, press the sound icon again. (Refer to
6.6 for more information on Mute mode).
Raise volume
level (+)
Lower volume
level (-)
Level 0
Level 1
Level 2
Level 3
Level 4
Level 5
TO LOWER VOLUME LEVEL TO L0
Press the
(-) button
to select the
L0 level
(see step 6.6)
TO TEST THE SOUND:
Ask someone to speak into the Nursery
Unit or place the unit near a radio to ensure
that sound is being picked up.
IMPORTANT
To avoid feedback (whistling), keep
both units at least 3 m apart (10 ft).
PUT IN TALK BACK MODE
Press and hold
the Talk Back
button to speak
to your baby.
IF YOU HEAR NO SOUND:
• Check that both units are switched on.
• Check that both units are plugged
into a working electrical outlet.
• Check the batteries in both units
(replace or recharge them as necessary
per unit).
• Bring the Parent Unit closer to the
Nursery Unit.
5.2 - BATTERIES
HOW TO CHECK THE BATTERIES:
Unplug the AC Adapters from both units.
• If the green light on the Nursery Unit does not show, replace the batteries.
• If the Parent Unit and its screen do not light up, recharge the batteries.
HOW TO CHARGE THE BATTERIES IN THE PARENT UNIT:
Leave the Parent Unit in the Charging Cradle
1/3 full2/3 fullfull
to fully charge the unit. Although the batteries
at 1/3 capacity works normally, we recommend
that you fully recharge them.
PARENT UNIT BATTERY ALARM
• Alarm activates when batteries need to be recharged.
• Parent Unit will emit a beep sound every 20 seconds.
ÉTAPE 6 - TO ACTIVATE AND DEACTIVATE ADDITIONAL FUNCTIONS
MULTIFUNCTIONAL
The Angelcare
according to your needs.
®
monitor is multifunctional. It can be use in different combinations
SOUND & MOVEMENT:
Allows you to detect the baby’s
MOVEMENT & SOUND while using both
Parent Unit and Sensor Pad.
12
Slide the Nursery Unit Connecting
switch to 1 to detect sound
and movement.
MOVEMENT ONLY:
Allows you to detect the baby’s MOVEMENT ONLY
without the Parent Unit. This combination can be useful
when the baby is in the same room as the parents.
112
Slide the Nursery Unit Connecting switch
to 2 to detect MOVEMENT ONLY. If the
Parent Unit is turned on, the Parent Unit
will only display the Out-of-Range icon.
SOUND ONLY:
Allows you to detect the baby’s SOUND ONLY without
the Sensor Pad. This combination can be useful if you
don’t want to use the Sensor Pad or if your baby is older
than 24 months (maximum age to use the Sensor Pad).
2
Slide the Nursery Unit Connecting switch to 1
to detect sound ONLY (Sensor Pad function
needs to be deactivated on the Parent Unit then
unplugged from the Nursery Unit).
NOTE:
To safely store just make sure to remove the Sensor Pad and cords
from the crib – disconnect sensor cord plug from the nursery unit
and safely store away in box for future use.
The Angelcare® monitor can be used with the pre-program factory settings
or you can also customise your settings to your preference.
NOTE: All changes
and adjustments made
in the settings mode will
not be activated unless
you confirm them by
pressing the Return icon.
A long beep will confirm
your modification.
IMPORTANT
When in settings mode, the sound
transmission between the Parent
and Nursery Unit will be temporarily
deactivated. ONLY the movement
alarm will remain active
(if function is already activated).
6.1 - VOICE ACTIVATION (VOX) OR CONTINUOUS SOUND MODE
Allows you to select your option on how you monitor sound:
VOX (voice activation picks up sound based on the selected sensitivity level settings) or
Continuous (sound monitoring is continuously on, picking up all sounds).
1
1) Press the VOX icon to activate
or deactivate the VOX function.
E
N
VOX ON
(VOX)
VOX OFF
(Continuous)
NOTE:
By deactivating VOX, the Continuous sound
TO ADJUST THE VOX SENSITIVITY:
setting is ON.
Allows you to determine the sound level needed to trigger sound transmission
to the Parent Unit.
1
2
4
1) Press the Settings icon to access
setting mode.
2) Press the VOX Sensitivity icon.
The icon will blink.
3) Use the (+) or (-) on the right side
of the Parent Unit to choose the desired
sensitivity level (1 to 4)
OR
press vox sensitivity icon to choose
Level 1
Level 2
3
Level 3
Level 4
the desired level.
4) Press Return icon to confirm your choice
and return to normal screen.
6.2 - ECO MODE
Allows you to reduce the electro-smog
and save battery life. Please note that while
in ECO mode the range will be reduced.
TO ACTIVATE ECO MODE:
1
3
1) Press the Settings icon to access
the setting mode.
2) Press the ECO icon to activate
or deactivate the ECO function.
ONOFF
2
3) Press the Return icon to confirm your
choice and return to normal screen.
The ECO icon will
appear next to the
Connection icon when
the function is active.
Allows you to select your preferred alarm mode for the Parent Unit.
1
3
1) Press the Setting icon to access
setting mode.
2) Press the Alarm icon , current alarm
mode
icon will blink. Then press again to select
the alarm mode as the display changes
2
for various modes.
3) Press the Return icon to confirm your
choice and return to normal screen.
Sound alarm only
Sound alarm
and vibration
Vibration only:
When the movement alarm is triggered, the Parent Unit will vibrate
and a sound alarm will be heard on the Nursery Unit.
When the Parent Unit is on
the charger, the sound alarm will
replace the vibration mode.
IMPORTANT
When in setting mode no sound or alarms will transmit to the Parent Unit,
except the movement alarm (if this function was already activated).
6.5 - HOLD
E
N
Allows you to put your Angelcare Monitor on HOLD.
1
1) Press the Settings icon to access
the setting mode.
2) Press the Hold icon
OR
Press the Nursery Unit Hold button
for 4 seconds.
2
3) Press the Hold icon for 4 seconds or
the Nursery Unit Hold button again
to return to normal operation.
2
NOTE:
When on HOLD, the Nursery Unit Power Light will
blink. The Parent Unit will emit beeps and/or vibrate
every 20 seconds to remind you that monitor is on
hold, depending on the type of alarm chosen.
IMPORTANT
When your monitor is on hold, the movement feature and Movement alarm are disabled.
• Ensure that you fully charge your batteries for 15hrs before their first use.
• To maintain maximum battery life it is recommended that you fully discharge
your batteries periodically. Battery performance can be diminished by leaving
the batteries constantly charging on the charging cradle. If your parent unit is not
in use, please turn it off.
• Inadequate battery power can impair the performance of your monitor. If you are not
happy with the performance of your Parent Unit/Monitor please replace the
rechargeable batteries (2 x NiMH Rechargeable Batteries).
• It is advisable to change the batteries every 6 months.
LOSS OF CONNECTIVITY
In the case of loss of connectivity, the first step is to bring the Parent Unit and Nursery Unit
closer together and make sure that both units are ON to restore the connection. If there is
still no connection and no out of range warning after the above has been done, then and
only then should the re-connection procedure below be done.
E
N
12
NOTE:
Make sure the Nursery
Unit Connecting switch
3 4
5
on the back of the unit
is in the position 1.
12
Re-connection procedure:
1) Turn on the Parent Unit and hold the
Talk button down for 2 seconds until
the Nursery Unit icon shows at the
center of the screen.
2) By pressing the Nursery Unit Icon
button the Parent Unit will be set in
to connectivity mode (the icon will
flash).
After 1 minute of non-operation, the Parent
Unit will exit the connectivity mode and you
will need to start this process again.
3) Press the Power button to turn on
the Nursery Unit. The Power LED
will light.
4) Then press the Power button 4 times
within 30 seconds. The Power LED will
blink. The connection procedure should
be completed within 10 seconds.
5) When the Parent Unit and Nursery
Unit are connected, H1 (or H2)
will be displayed on the Parent Unit
and then be followed by the normal
mode screen.
NOTE:
By doing the re-connection procedure you
will reset the monitoring system back to
original presets.
• Verify the connection between Sensor Pad and Nursery Unit.
Unplug and reconnect the cord.
• Make sure there is no bedding between mattress and Sensor Pad.
• If the crib has a spring or slat base, place a hardboard between the crib base
and the Sensor Pad measuring at least 13” x 13” (33x33 cm) and 1/4” (6 mm) thick.
• Make sure Sensor Pad is positioned as described under the setup requirements.
Sensor Pad Sensitivity level may need to be adjusted, refer to step 5.1.
ALARM WILL NOT SOUND
• Avoid contact with the crib when the monitor is ON.
• Place crib near a solid supporting wall to avoid Sensor Pad from detecting movement
from outside the crib.
• You may need to decrease the sensitivity, refer to step 5.1.
• Turn OFF crib mobile, fans, loud music or anything else that may cause vibration.
NO SOUND IS BEING TRANSMITTED
• Ensure that both units are switched ON.
• If there is no power to any unit check/replace the batteries, recharge the Parent Unit
& check the AC Adaptors are working. Change electrical outlets if required.
• Check on the Parent Unit screen to see if the monitor is in MUTE mode instead of ON
mode. Refer to step 6.6. and increase volume level.
• Bring the Parent Unit and Nursery Unit closer together.
NURSERY UNIT POWER ON INDICATOR (GREEN LIGHT) DOES NOT LIGHT UP
• Check the connections or change to another electrical outlet.
• Push and hold the left ‘wing’ for 2 seconds to turn the Nursery Unit ON.
WEAK RECEPTION
• Bring the units closer together.
• Change the position of one or both units.
• Place the units on a flat surface away from baby’s reach.
• Replace the batteries or recharge the Parent Unit.
STATIC, DISTORTION, INTERFERENCES
(FROM OTHER MONITORS, WIRELESS PHONES, WALKIE-TALKIES, ETC...)
• Rotate the Parent Unit or move it away from source of interference.
FEEDBACK (LOUD NOISES EMITTED FROM THE PARENT UNIT)
• Move the units farther apart (at least 10 feet apart/3 meters).
• Decrease volume on the Parent Unit.
THE PARENT UNIT SCREEN IS BLACK (PARENT UNIT IS OFF)
• Turn the Parent Unit back ON by pushing and holding the Power button.
• Replace the batteries or recharge the Parent Unit.
LIMITED WARRANTY
Angelcare® warrants to the original owner of this product that Angelcare® rechargeable
TOUCHSCREEN MOVEMENT & SOUND MONITOR (model AC701) is free from any material
and workmanship defects, for a period of one (1) year (Rechargeable batteries
not included) from the date of the original purchase. If this monitoring system fails to
function properly when used as directed under normal conditions within the one year
period, Angelcare
®
will either repair or replace the product, at our discretion, free of
charge. Please contact your distributor.
The product must be accompanied by a proof of purchase, either a bill of sale or other
proof that the monitoring system is within the warranty period. Angelcare
®
will bear the
cost of repairing or replacing the product and shipping it back to you.
This warranty does not apply to a product which has been damaged as a result of
improper maintenance, an accident, improper voltage supply or any other form of
misuse. The warranty is also void if the owner repairs or modifies the product in any
way. Angelcare
®
is not liable for any incidental or consequential damages with regard
to this product. The warranty also excludes any liability other than what is stated above.
No other warranty is given.
LEGAL RIGHTS VARY FROM COUNTRY TO COUNTRY. SOME COUNTRIES DO NOT
ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL
DAMAGES, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU.
WE ARE NOT IN ANY WAY RESPONSIBLE FOR ANY OUTCOME RESULTING
FROM THE USE OF THIS PRODUCT.
IMPORTANT!
®
This Angelcare
monitor is a personal care product. Please do not return this product
to the store. If you have questions or need help, please call your distributor before
returning this product.
E
N
REGISTER ANGELCARE PRODUCTS
Register your Angelcare® monitor and other
Angelcare
®
products on our website:
www.angelcarebaby.com
ANGELCARE MONITORS INC.
9975, avenue De Catania, Local B
Brossard, Québec, Canada
J4Z 3V6