Movement Sensor with Sound Monitor ..............................2
Détecteur de mouvements avec moniteur de sons..........13
Sensor de movimientos con monitor de sonidos .............25
OWNER’S MANUAL
Keep for future reference
AC601
MANUEL DE L’UTILISATEUR
À garder pour référence ultérieure
MANUAL DEL PROPIETARIO
Guarde para uso futuro
Failure to follow these warnings and the assembly instructions
could result in serious injury or death.
This product is designed to aid in the monitoring of
your child. When using the monitor, you must still provide the supervision necessary for the continued safety of your child. Always be sure that both the transmitter and receiver are working properly and are within
range of each other.
• STRANGULATION HAZARD. Keep the adapter cords
out of the reach of children. Do not use with extension
cords.
• DO NOT place the Nursery Unit or its cord within your
child’s reach. Do not put the Nursery Unit inside a crib
or playard.
• Use ONLY with 110-120 volt AC electrical outlets.
• Protect the AC adapter cords. Place them so they are
not walked on or pinched by furniture or other items.
• Allow for proper ventilation when units are in use. Do
not cover the Nursery Unit or Parent Unit with any
object such as a blanket. Do not place it in a drawer or
in any location which would muffle the sound or interfere with the normal flow of air.
The sensor pad is made of plastic and does not permit
the air to circulate. Therefore, mildew build up could
develop underneath the mattress in the sensor pad
area. We suggest rotating the mattress regularly to
prevent any mildew.
• DO NOT immerse any part of the Nursery Unit or
Parent Unit in water. Clean only with a dry cloth.
• DO NOT place unit near water and moisture. Do not
use the Nursery Unit outdoors. Do not use the Nursery
Unit near possible wet areas, such as a bathtub, shower, wash basin, sink, laundry tub, swimming pool, wet
basement, etc.
• Keep Nursery Unit away from heat sources, such as
fireplaces, radiators, stoves, and TVs or other appliances. Heat can damage the case or electrical parts.
• DO NOT OPEN THE NURSERY UNIT, PARENT UNIT
OR ADAPTERS.
No user-serviceable parts inside. Risk of electrical
shock, fire or death.
• The antenna used for this transmitter must be
installed to provide a separation distance of at least 20
cm (7.9”) from all persons and must not be co-located
or operating in conjunction with any other antenna or
transmitter.
DO NOT use these adapters with any other equipment.
Use only with the provided adapters.
• When unplugging the AC adapter from the nursery
unit, be sure it is switched to the off position. If it isn’t,
the unit will revert to battery mode if batteries are
installed.
• Always place both the Nursery Unit and Parents’ Unit
on a flat surface in an upright position and allow for
proper ventilation.
• Avoid damage to the Sensor Pad cord and to the
adapter cords. Route cords so that they are not likely to
be walked on or pinched by items placed on or against
them.
• Route sensor pad cord only below crib mattress and
out of reach of children.
• Use ONLY AAA (LR03) batteries (included) and/or the
AC adapters provided for the Parents’ Units.
• During long periods of non-use remove all batteries
from their compartments and unplug the AC adapters.
• This monitor uses public airwaves to transmit signals. The Parents’ Unit may pick up signals or interference from other nursery monitors in your area. Your
monitor may even be picked up by other households.
To protect your privacy, make sure both units are
turned off when not in use. If you experience
interference, change the channel on both units.
WARNING: This product is not a toy.
• Do not use the Nursery Unit if:
• The adapter cords or plugs have been damaged.
• The unit has been exposed to liquids.
• Unit has been dropped or is damaged.
2
• This monitor is perfectly safe. The Sensor Pad and
its cord are entirely passive. They carry no electrical
current and do not radiate any form of energy. The
Nursery Unit emits only very low power radio signals
through its antenna. These signals do not present a
safety hazard.
• When the monitor is in use, do not use a crib mobile
or other crib accessories that may produce vibrations. Other sources of vibrations may include fans,
washing machines, loud music, etc. These sources of
vibration may interfere with the performance of your
Angelcare® monitor and the alarm will not sound if it
continues to detect any movement other than your
baby’s. Be sure all vibration sources are eliminated
before using the monitor.
Modifications not authorized by the manufacturer may
void users authority to operate this device.
NOTE: This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed
and used inaccordance with the instructions, may
cause harmful interference to radio communications.
• You may experience false alarms for several reasons. The most common reason is the Nursery Unit
has not been turned off after you have removed your
baby from the crib. Another reason is the Sensor Pad
has not been placed under the mattress properly. Be
sure the Sensor Pad is on a flat, firm surface with the
turquoise side facing up. The sensitivity level may
also need to be adjusted. Refer to the Movement
Sensitivity Adjustment section on Page 7.
• Always be sure to immediately check on baby
whenever an alarm sounds.
• Your monitor can be used in any crib that is stationary and designed to safely hold a baby. If your crib
has a spring or slat base you will need to place a
piece of Masonite board under the Sensor Pad. This
support must be at least 13 inches long on all four
sides and 1/4 inch thick. Only use your Angelcare®
monitor in a stationary sleeping environment such as
a crib where the Sensor Pad can rest on a completely flat, firm surface.
• CLEANING. Disconnect all units before cleaning. DO
NOT immerse in water. Use a dry cloth to keep monitor free from dust. DO NOT spray with cleaning products or solvents. Wipe sensor pad with a cloth moistened very slightly with an antiseptic or mild detergent.
However, there is no guarantee that interference will
not occur in a particular installation. If this equipment
does cause harmful interference to radio or television
reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment
and receiver.
• Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful
interference, and
(2) This device must accept any interference
received,including interference that may cause undesired operation.
3
eatures
F
P
arent Unit
Out of range (orange)
Bar graph LEDs
Sound Level / Alarm
/ Charging indicators
Channel
selection
Ch.ACh.BCh.C-
(green)
Volume / Power
-High
-Medium
-Low
-Off
Power / Low
batteries (green)
Speaker
150mA
7.5V
AC601Model:
AC adapter
DC 7.5V IN
Battery compartment
3 x AAA rechargeable
batteries (NiMH)
Installing Batteries in Parents Unit
•
TheParents Unit requires three AAA rechargeable NiMH batteries (included).
T
o insert batteries, remove the battery cover on the back of the unit and insert the batteries matching positive (+) to
•
positive (+) and negative (-) to negative (-) and replace the battery cover.
Lea
•
ve the AC adapter plugged to the Parents Unit for 15 continuous hours before using your monitor to fully charge
rechargeable batteries.)
Recharge
•
•
IMPOR
•
adapter.
The
the batteries when the Low Battery Indicator flashes and turns orange instead of green by plugging in the AC
AC adapter can also be used as an alternative operation power source.
TANT:Use only the AC adapters included with your monitor. Do not use these adapters with any other equipment.
Nursery Unit
Night light
ON/ OFF
Night light
button
Channel
selection
Ch.ACh.BCh.C-
Installing Batteries in Nursery Unit
•
The Nursery Unit requires four AAA alkaline batteries in case of AC power failure (included).
T
•
o insert batteries, remove the battery cover on the bottom of the unit and insert the batteries matching positive (+)
to positive (+) and negative (-) to negative (-) and replace the battery cover.
Insert
•
•
•
the AC adapter into the Nursery Unit and plug the adapter into an electrical outlet. Unit will run off of the AC
adapter unless there is a power outage, in which case the unit will begin using the batteries.
Replace
the batteries when the Low Battery Indicator flashes. If the batteries are not replaced, the monitor
will stop working.
IMPOR
TANT:Use only the AC adapters included with your monitor. Do not use these adapters with any other equipment.
Out of range LED (orange)
Mode select
- Sound, Movement & Tic
- Tic Off
- Sound only
Movement alarm LED (green)
Power / Low batteries (green)
Microphone
POWER ON / OFF
TicOffTic
Sound Only
Sensor
Sensor
pad
pad
Off
&Sound Movement
AAA
4x1.5V
AAA
Alarm sound speaker
Sensor pad socket
Sensitivity adjustment dial
AC601AC601Model:
ivitySensSensit
150mA
7.5V
DC 7.5V IN
Battery back up
compartment
(4 AAA alkaline batteries)
4
AC adapter
Loading...
+ 8 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.