Angelcare Monitors AC401 User Manual

AC401 manuel ENG V4.qxd 4/25/07 3:39 PM Page 1
Rechargeable Movement & Sound Monitor Moniteur de mouvements et de son rechargeable
AC401
AC401 manuel ENG V4.qxd 4/25/07 3:39 PM Page 2
TABLE OF CONTENT
Your Angelcare® Monitor components and special features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
How to operate your Angelcare®Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Testing your Angelcare®Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Maintenance of your Angelcare®Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Distributors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
YOUR ANGELCARE®MONITOR COMPONENTS
NURSERY UNIT
(TRANSMITTER)
RECHARGEABLE PARENTS
UNIT (RECEIVER) &
CHARGER
YOU WILL ALSO NEED :
4 AAA non-rechargeable batteries(not included) as back up for the nursery unit in case of power failure.
4 AAA RECHARGEABLE
BATTERIES FOR
PARENTS UNIT
2 (Two) 7.5 volt AC adapters
FEATURES
Practical soothing
night light.
Choice of voice activated or
continuous sound reception.
Convenient belt clip.
Nursery room temperature
display on the parents unit.
ALARM AND WARNING
Your Angelcare©monitor will let you know if no movement is detected by alarms, vibration and visual effects.
An alarm is triggered on the
nursery unit and the flashing
pendulum green light
stops flashing.
The practical portable parents unit keeps you informed at all time.
m is triggered on the
An alar
ents unit.
par
Vibration on the parents
unit.
The par
and the nurser
2
SENSOR PAD(S) 1 or 2
ents unit lights up
y unit icon
appears.
AC401 manuel ENG V4.qxd 4/25/07 3:39 PM Page 3
HOW TO OPERATE YOUR ANGELCARE®MONITOR
STEP 1
INSTALLATION OF THE SENSOR PAD UNDER THE MATTRESS
POSITION OF SENSOR PAD UNDER MATTRESS
I sensor pad 2 sensor pads
Sensor Pad(s) 1 or 2
Keep at
least 38 cm
(
15 inches)
a
part
Crib center Crib center
• Position the sensor pad as shown above.Make sure the printed side faces up. Do place any bedding between the mattress and the sensor pad.
• Secure the sensor pad cord to crib using a tie wrap. Run the cord on the floor to ensure it is out of the baby’s reach.
• The sensor pad must rest on a completely flat and rigid surface. Place a 6mm (1/4”) plywood to cover the full size of the crib base. Make sure the sensor pad’s cord passes underneath the mattress as shown above.
STEP 2
INSTALLATION OF THE NURSERY UNIT
Sensor pad cord socket
Adapter socket
• Connect the long sensor pad cord into the nursery unit.
• Insert 4 AAA regular batteries (not included) into nursery unit (for battery backup in case of power failure).
• Connect AC adapter to nursery unit and plug adapter into an electrical outlet in the baby’s room.
STEP 3
Sensor pad sensitivity dial
Battery compartment
INSTALLATION OF THE PARENTS UNIT
pter
pter
Charger ada
Charger ada socket
socket
• After both units are properly installed you may adjust the sensor pad sensitivity level (if necessary).
• Insert 4 AAA NIMH rechargeable batteries (included) into parents unit. NEVER use regular alkaline batteries.
• Connect AC adapter to parents unit charger and plug adapter into an electrical outlet. Let charge for 15 continuous hours before using the monitor for the first time.
STEP 4
Parents unit
pa
ON/ OFF Night
light button
wer ON/OFF
o
P
Movement
capture indicator
(Flashing)
Power ON indicator
y
tter
w ba
Lo
indicator
Microphone
Speaker
Battery compartment
HOW YO USE YOUR ANGELCARE© MONITOR
ger
Power ON/OFF
Sound volume
UP/DOWN
• Once the parents unit is fully charged (after 15 hours) turn the unit ON and turn the nursery unit ON.
If the parents unit is turned ON and the nursery unit is OFF, the parents unit will start beeping after 1 minutes. After 4 seconds, the unit will shuts itself off.
• The different available options are programmable but you can use the units right away, with the following factory settings :
- Sound, movement and tic activated
- Out of range notifica
tion OFF
- Voice activated ON
- Temperature display ON, Room temperature control OFF
- P
arents unit alarm ON,
vibration OFF
- Speaker volume at 3
- Voice sensitivity at 2
T
o avoid feedback (whistling sound), keep both units at least 3 meters
apart (10 feet).
• You can adjust the sound volume with the arrow buttons.
o turn the night light ON,
T
move the right wing button UP.
3
AC401 manuel ENG V4.qxd 4/25/07 3:39 PM Page 4
STEP 5
STEP 6
STEP 7
SCREEN AND BUTTONS
All programmable functions of your Angelcare© monitor are available through the MENU
When the desired option appears on your screen, press SELECT.
• AT ANY TIME after programming a function, if you wish to exit the menu selection, press on the EXIT button. If you wish to perform additional programming press MENU to view the next option.
TICS, SOUNDS AND MOVEMENTS
Your Angelcare© monitor gives you the possibility to chose what you wish to monitor.
- The “TIC” is a sound that tells you that your sensor pad is detecting movements.
- The “SOUND” function is activated by the baby’s voice or continuous or is transmitted
continuously (see STEP 8)
TIC SOUND MOVEMENT
- The “MOVEMENT” function is activated when movement is detected by the sensor pads.
It detects all baby’s movements and warns you when there is no movement.
A CONTINUOS BEEPING SOUND is heard when no movement is detected for 20 seconds.
If you are receiving false alarms, adjust the sensor pad sensitivity level (STEP 2).
• Press MENU, the 3 flashing icons will appear.
• Using the arrows, select each icon, and decide if you want it ON or not.
• When your selection is made press SELECT, and it will bring you to the next icon.
• Press MENU to view the next option, or EXIT if you wish to stop programming now.
OUT OF RANGE INDICATOR
Your monitor is equiped with an optional “Out of range” indicator function, which will advise you when the two units are not communicating with each other. Out of range situations can be caused by distance or by physical interferences. Range: up to 250 meters/ 820 ft (open field); between 80 meters/ 262 ft and 100 meters/328 ft (indoors).
When the units are out of range you will hear a DOUBLE BEEP every 8 seconds and the “out of range”icon will flash on the screen of the parents unit.
STEP 8
• Press MENU, the OUT OR RANGE icon and the word OFF will appear on the screen.
• Turn this function ON or OFF by using the arrows.
• Press SELECT
• Press MENU to view the next option, or EXIT if you wish to stop programming now.
MICROPHONE SENSITIVITY
The sound monitoring can be “voice activated” or “continuous”. If you choose the continuous transmission mode, you will hear your baby’s every little sounds. If you use “voice activated” you will hear sounds depending on the level of sensitivity tha
• Press MENU, the MICROPHONE and the word ON will appear on the screen.
• Leave it ON to keep it “voice activated”or OFF to be in “continuous” mode. Use the arrows to select On or OFF.
• Press SELECT.
• If you wish to use the voice activated monitoring function, Press MENU again to chose the level of sensitivity of the microphone (4 levels), using the arrows.
• Press SELECT when the desired level appears on the screen.
• Press MENU to view the next option, or EXIT if you wish to stop programming now.
t you choose.
4
AC401 manuel ENG V4.qxd 4/25/07 3:39 PM Page 5
STEP 9
STEP 10
STEP 11
ALARMS AND VIBRATION
This menu allows you to chose between the following notification options :
- Alarm only
- Vibration only
- Alarm and vibration
NOTE : The vibration mode will not work when the batteries are low or if the parents unit is on the charger.
• Press MENU and chose the desired option. The wave icon is for the vibrationmode and the ell icon is for the alarm mode.
b
• Select the desired option, using the arrows. Press SELECT.
• Press MENU to view the next option, or EXIT if you wish to stop programming now.
ROOM TEMPERATURE CONTROL
Your Angelcare© monitor can also monitor your baby’s room temperature and let you know when the temperature is to high or too low. A tripple BEEP will be heard if the temperature reaches levels out of the chosen range.
• Press MENU, the snow flake and sun icons and the word OFF will appear on the screen.
• Turn it ON or OFF using the arrows.
• Press SELECT.
• If you select to have the room temperature control ON, Press MENU.
The SNOW FLAKE icon will appear, with the temperature. Select the desired lowest
temperature with the arrows and press SELECT.
• Press MENU. The SUN icon will appear, with the temperature. Select the desired highest
temperature with the arrows and press SELECT.
• Press EXIT as this was the last available programmable function.
BATTERY MODE AND WARNINGS
w ba
Lo
Low ba
tor
indica Red light
ttery indicator
y
tter
• The monitor will revert to battery mode during a power failure only if batteries are inserted
in both units.
• It is also possible to use the Angelcare© monitor in places where electricity is not available.
• When the nursery unit’s low battery RED light is flashing, its batteries need to be replaced. On the screen of the parents unit, the battery icon flashes and the nursery unit icon appears. A short BEEP will also be heard every 15 seconds for about 30 minutes, until the unit shuts itself off.
• Parents unit should be recharged when icon is clear (will not flash) and a beep sound is heard. A short BEEP sound will be heard every 15 seconds until the unit shuts itself down.
Note: Do not use Alkaline batteries in the parents unit. IMPORTANT : If the “Out of range” function is ON, when the nursery unit shuts itself off, the
“Out of range” signal will be heard and displayed on the parents unit.
STEP 12
ADDITIONAL FUNCTIONS
•CONNECTING
• PAGING: If you want to locate the parents unit, press the top button of
CHANNEL SELECTION : If the transmission is not clear, or if you hear parasite sounds,
TEMPORARY MUTE : If you want to mute the sound for 2 minutes, press the center
THE P
you should change the channel. Press and hold the SELECT button to change the channel (with the arrows). Then press the SELECT button a
EXIT button. elapsed, press EXIT again. You can also turn the alarm off by pressing the same button (this does not a battery alarm).
ARENTS UNIT TO THE NURSERY UNIT:
If you lose the connection between the 2 units, press and hold the MENU button on the parents unit, indicator will flash. Press and hold the top button of the nursery unit to re-connect to the nurser
the nursery unit.
gain to confirm.
o reactivate the sound before the 2 minutes have
T
the "out of range"
y unit. The Tic light flashes.
pply to the the lo
5
w