![](/html/09/0918/0918c732263613fcfe7d927cf81937cff64c2d21ee116577ddbd48f19150bd61/bg1.png)
WARNING!
at least 20 centimeters must be maintained between radiating antennas
and the body of the user or nearby persons in order to meet the FCC RF
exposure guidelines.
While this device is in operation, a separation distance of
Appendix A : Installation Checklist
The following checklist provides a summary of the procedures for installing a MR703D system:
Step Ite m/ Ac ti on Description
1
2
3
4
5
6
7
8
9
10
11
*
MR703D Site Drawing
Equipment List: Quantity:
MR703D
AC Power Outlet
Coverage Antenna*
Donor A ntenna
50-ohm Donor Antenna Cable
50-ohm Do nor Jumper*
50-ohm Coverage Antenna Cable
Installation tools:
Cable connector Tools*
Multimeter
Handset with Power Indicator
Run Cable
Attach Connectors*
Verify “Donor and
CoverageAntennas ” locations are
consistant with RF exposure warning
(see above and below).
Record Serial Numbers and Locations
on site Drawing.
Mount the Equipment
Connect the 50-ohm Cables as shown
on the Site Plan
Supply AC Power, and commission
the System.
Check Power Levels
As Required
Master copy of the site plan noting the MR703D location and
serial number, and the location of the indoor coverage
antenna(s)). This should characterize the design parameters
for the system including cable paths and lengths.
Crimper, knife, etc.
To ensure no cable shorts.
To verify coverage after commissioning.
Install Cable in the site.
Measure across center pin and outer shell (ground) to ensure
no short.
Be sure to record the antennas location status for future
reference.
Note: this is to aid the Mikom Technical Support Specialists,
should you need their assistance.
Including indoor coverage antennas for metal case models.
Use caution when connecting semi-flexible cables to the
mounted MR703D and antennas. Excessive force on antenna
or MR703D connectors will result in serious equipment
damage.
Check the MR703D status as described in previous section .
Check power indication of handheld mobile at various
locations within the coverage area.
♦
WARNING!
at least 20 centimeters must be maintained between radiating antennas
and the body of the user or nearby persons in order to meet the FCC RF
exposure guidelines.
Appendix A : Installation Checklist:MR703D Users Guide Manual 149678 (m0041a3a, 5\00) Page A-1
While this device is in operation, a separation distance of