ANALOG DEVICES UG-146 Service Manual

Evaluation Board User Guide
ADE78xx
P1P2
P3
P4
P5 P6 P7 P8 P9
IAPIANIBP
IBN
ICP ICN
INP INN
GNDVN GNDVCP GNDVBP GNDVAP GNDVDD
FILTER
NETWORK
FILTER NETWORK
AND ATTENUATION
ADR280
OPTIONAL EXTERNAL
1.2V REFERE NCE
OPTIONAL EXTERNAL CLOCK IN
DIGITAL
ISOLATORS
LPC2368
P10
GND2VDD2
P12
MCU_GNDMCU_VDD
USB PORT
J2 J3 J4
CF3 CF2 CF1
P13
JTAG
INTERFACE
P15
CONNECTOR TO
PC COM PORT
09078-001
UG-146
One Technology Way P.O. Box 9106 Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.461.3113www.analog.com
Evaluating the ADE7878 Energy Metering IC

FEATURES

Evaluation board designed to be used with accompanying
software to implement a fully functional 3-phase energy
meter Easy connection of external transducers via screw terminals Easy modification of signal conditioning components using
PCB sockets LED indicators on the CF1, CF2, CF3, IRQ0, and IRQ1 logic
outputs Optically isolated metering components and USB-based
communication with a PC External voltage reference option available for on-chip
reference evaluation PC COM port-based firmware updates

GENERAL DESCRIPTION

The ADE7878 is a high accuracy, 3-phase electrical energy measurement IC with serial interfaces and three flexible pulse outputs. The ADE7878 incorporates seven ADCs, reference circuitry, and all signal processing required to perform total (fundamental and harmonic) active, reactive, and apparent energy measurement, fundamental active and reactive energy measurement, and rms calculations.
This user guide describes the ADE7878 evaluation kit hardware, firmware, and software functionality. The evaluation board contains an ADE7878 and a LPC2368 microcontroller (from NXP Semiconductors). The ADE7878 and its associated metering components are optically isolated from the microcontroller. The microcontroller communicates with the PC using a USB interface. Firmware updates can be loaded using one PC com port and a regular serial cable.
The ADE7878 evaluation board and this user guide, together with the ADE7878 data sheet, provide a complete evaluation platform for the ADE7878.
The evaluation board has been designed so that the ADE7878 can be evaluated in an energy meter. Using appropriate current transducers, the evaluation board can be connected to a test bench or high voltage (240 V rms) test circuit. On-board resistor divider networks provide the attenuation for the line voltages. This user guide describes how the current transducers should be connected for the best performance. The evaluation board requires two external 3.3 V power supplies and the appropriate current transducers.
PLEASE SEE THE LAST PAGE FOR AN IMPORTANT WARNING AND LEGAL TERMS AND CONDITI ONS.

EVALUATION BOARD CONNECTION DIAGRAM

Rev. 0 | Page 1 of 36
Figure 1.
Loading...