ANALOG DEVICES AN-1154 Service Manual

AN-1154
APPLICATION NOTE
dp
dQ
DEAD ZONE
BLEED CURRENT P US HE S THE CHARGE PUMP O UT OF DEAD ZONE
10729-001
One Technology Way P. O. Box 9106 Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.461.3113 www.analog.com
Optimizing Phase Noise and Spur Performance of the ADF4157 and ADF4158 PLLs
Using Constant Negative Bleed

INTRODUCTION

The phase noise (PN) and integer boundary spur (IBS) performance of the ADF4157 and the ADF4158 can be improved by activating a constant negative bleed current. The biggest improvement is achieved at frequencies at, or close to, integer multiples of the phase frequency detector (PFD) frequency. It is more visible for loop bandwidths greater than 60 kHz; however, it is recommended to use constant negative bleed for all PLL loop bandwidths.
Constant negative bleed current works by adding a constant offset to the charge pump (equivalent to a phase offset in the PLL loop). This has the effect of linearizing the charge pump by moving away from the nonlinear area near the origin (sometimes referred to as the charge pump dead zone). Figure 1 illustrates this phenomenon.
Figure 1. The Effect of Bleed Current on Charge Pump
Without this constant current offset, sigma-delta quantization (dQ) noise can fold back in-band and cause excessive noise or spurs. This aliasing of sigma-delta noise in-band only happens for high resolution sigma-delta modulators (equivalent to high value of modulus) as used on the ADF4157 and ADF4158. These parts require activation of a constant negative bleed current to achieve optimal phase noise and spur performance. This current is not needed for other Fractional-N PLLs with lower value of modulus or Integer-N PLLs.
The constant negative bleed on the ADF4157 and ADF4158 is activated by setting bits DB[24:23] in Register 4 to 0b11.

THE EFFECT OF BLEED CURRENT ON PHASE NOISE AND SPURS

The use of a constant negative bleed only improves phase noise and integer boundary spurs for a certain range of charge pump currents (I can degrade. This phenomenon was measured for two PFD frequencies, 12.5 MHz and 25 MHz. Each PFD frequency was tested near two consecutive integer channels. The loop filter configuration for each PFD frequency is show in the Appendix.
). For some values of ICP, phase noise and spurs
CP

HOW MEASUREMENTS WERE RECORDED

The measurements were recorded on an EV-ADF4157SD1Z evaluation board. The loop filter was modified for each PFD frequency.
1. The loop was locked at 5800.001 MHz using a PFD
frequency of 25 MHz.
2. The charge pump current was set to the minimum value
(0.31 mA).
3. Negative bleed was disabled.
4. The phase noise at a 5 kHz offset and the integer boundary
spur at 1 kHz were recorded.
5. Negative bleed was enabled.
6. The phase noise at a 5 kHz offset and the integer boundary
spur at 1 kHz were recorded.
7. Step 3 to Step 6 were repeated for every charge pump
current setting up to 5 mA.
8. Step 2 to Step 7 were repeated with the loop locked at
5825.001 MHz.
9. The loop filter was modified for a PFD frequency of
12.5 MHz, the loop was locked at 5800.001 MHz using a PFD frequency of 12.5 MHz. Step 2 to Step 8 were repeated.
Rev. 0 | Page 1 of 8
AN-1154 Application Note
TABLE OF CONTENTS
Introduction ...................................................................................... 1
The Effect of Bleed Current on Phase Noise and Spurs .............. 1
How Measurements Were Recorded .............................................. 1
Revision History ............................................................................... 2

REVISION HISTORY

5/12—Revision 0: Initial Version
Results .................................................................................................3
Analysis of Results .............................................................................4
Conclusion..........................................................................................4
Appendix ............................................................................................5
Rev. 0 | Page 2 of 8
Application Note AN-1154
0
PN (dBc/Hz) ; IBS (dBc)
0
PN (dBc/Hz) ; IBS (dBc)
0
PN (dBc/Hz) ; IBS (dBc)
0
PN (dBc/Hz) ; IBS (dBc)

RE S U LT S

PFD Frequency = 25 MHz

Output frequency = 5800.001 MHz
RF
= 5800.001MHz; PFD = 25MHz
–10
–20
–30
–40
–50
–60
–70
–80
–90
0.31 1.31 2.31 3.31 4.31
OUT
CHARGE PUMP CURRENT (mA)
Figure 2. Phase Noise and IBS at 5800.001 MHz with
a PFD Frequency = 25 MHz
Output frequency = 5825.001 MHz
PN AT 5kHz; BLE E D OFF IBS; BLEED OFF PN AT 5kHz; BLE E D ON IBS; BLEED ON
10729-002

PFD Frequency = 12.5 MHz

Output frequency = 5800.001 MHz
RF
= 5800.001MHz; PFD = 12.5MHz
–10
–20
–30
–40
–50
–60
–70
–80
–90
0.31 1.31 2.31 3.31 4.31
OUT
PN AT 5kHz; BLE E D OFF IBS; BLEED OFF PN AT 5kHz; BLE E D ON IBS; BLEED ON
CHARGE PUMP CURRENT (mA)
Figure 4. Phase Noise and IBS at 5800.001 MHz with
a PFD Frequency = 12.5 MHz
Output frequency = 5825.001 MHz
10729-004
RF
= 5825.001MHz; PFD = 25MHz
–10
–20
–30
–40
–50
–60
–70
–80
–90
0.31 1.31 2.31 3.31 4.31
Figure 3. Phase Noise and IBS at 5825.001 MHz with
OUT
PN AT 5kHz; BLE E D OFF IBS; BLEED OFF PN AT 5kHz; BLE E D ON IBS; BLEED ON
CHARGE PUMP CURRENT (mA)
–10
–20
–30
–40
–50
–60
–70
–80
–90
0.31 1.31 2.31 3.31 4.31
10729-003
Figure 5. Phase Noise and IBS at 5825.001 MHz with
a PFD Frequency = 25 MHz
RF
= 5825.001MHz; PFD = 12.5MHz
OUT
PN AT 5kHz; BLE E D OFF IBS; BLEED OFF PN AT 5kHz; BLE E D ON IBS; BLEED ON
CHARGE PUMP CURRENT (mA)
a PFD Frequency = 12.5 MHz
10729-005
Rev. 0 | Page 3 of 8