Your Amprobe product will be free from defects in material and workmanship for 1 year from
the date of purchase, unless local laws require otherwise. This warranty does not cover fuses,
disposable batteries or damage from accident, neglect, misuse, alteration, contamination, or
abnormal conditions of operation or handling. Resellers are not authorized to extend any other
warranty on Amprobe’s behalf. To obtain service during the warranty period, return the product
with proof of purchase to an authorized Amprobe Test Tools Service Center or to an Amprobe
dealer or distributor. See Repair Section for details. THIS WARRANTY IS YOUR ONLY REMEDY.
ALL OTHER WARRANTIES - WHETHER EXPRESS, IMPLIED OR STAUTORY - INCLUDING IMPLIED
WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, ARE HEREBY
DISCLAIMED. MANUFACTURER SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL
OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since
some states or countries do not allow the exclusion or limitation of an implied warranty or of
incidental or consequential damages, this limitation of liability may not apply to you.
Repair
All test tools returned for warranty or non-warranty repair or for calibration should be
accompanied by the following: your name, company’s name, address, telephone number, and
proof of purchase. Additionally, please include a brief description of the problem or the service
requested and include the test leads with the meter. Non-warranty repair or replacement charges
should be remitted in the form of a check, a money order, credit card with expiration date, or a
purchase order made payable to Amprobe® Test Tools.
In-Warranty Repairs and Replacement – All Countries
Please read the warranty statement and check your battery before requesting repair. During the
warranty period any defective test tool can be returned to your Amprobe® Test Tools distributor for
an exchange for the same or like product. Please check the “Where to Buy” section on www.amprobe.
com for a list of distributors near you. Additionally, in the United States and Canada In-Warranty repair
and replacement units can also be sent to a Amprobe® Test Tools Service Center (see address below).
Non-Warranty Repairs and Replacement – US and Canada
Non-warranty repairs in the United States and Canada should be sent to a Amprobe® Test Tools
Service Center. Call Amprobe® Test Tools or inquire at your point of purchase for current repair
and replacement rates.
In USA In Canada
Amprobe Test Tools Amprobe Test Tools
Everett, WA 98203 Mississauga, ON L4Z 1X9
Tel: 877-AMPROBE (267-7623) Tel: 905-890-7600
Non-Warranty Repairs and Replacement – Europe
European non-warranty units can be replaced by your Amprobe® Test Tools distributor for a
nominal charge. Please check the “Where to Buy” section on www.amprobe.com for a list of
distributors near you.
European Correspondence Address*
Amprobe® Test Tools Europe
Beha-Amprobe GmbH
In den Engematten 14
79286 Glottertal, Germany
Tel.: +49 (0) 7684 8009 - 0
www.amprobe.eu
*(Correspondence only – no repair or replacement available from this address. European
customers please contact your distributor.)
IR-712 12:1 IR Thermometer
IR-720 20:1 IR Thermometer
IR-730 30:1 IR Thermometer
3
1110
56
14
9
12
15
13
7
8
4
Laser Aperture
1
Trigger
2
Battery Cover
3
Display
4
Laser “ON” symbol
5
Display backlight
6
Measurement lock
7
(Continuous measurement)
Temperature unit (Celsius / Fahrenheit)
8
8 seconds auto display hold
9
10
Making measurement (Pulling the trigger)
11
Battery indicator
12
Primary display
13
Secondary display
14
Emissivity (Adjustable from 0.10 to 1.00)
15
MAX, MIN, DIF, AVG temperature values
1
2
IR-712 12:1 IR Thermometer
IR-720 20:1 IR Thermometer
IR-730 30:1 IR Thermometer
CONTENTS
SYMBOL .................................................................................................................2
SAFETY INFORMATION .........................................................................................2
UNPACKING AND INSPECTION .............................................................................3
FEATURES ...............................................................................................................4
HOW THE THERMOMETERS WORK .....................................................................5
OPERATING THE THERMOMETER .........................................................................5
Temperature Measurement .............................................................................5
Locating a Hot or Cold Spot ............................................................................10
Distance and Spot Size .....................................................................................11
Field of View......................................................................................................12
Warning! Laser light. Do not stare into laser beam.
Celsius.
°C
Fahrenheit.
°F
Battery indication.
Complies with European Directives.
Do not dispose of this product as unsorted municipal waste.
Contact a qualified recycler.
SAFETY INFORMATION
The instrument complies with:
EN 61010-1 General Safety
EN 60825-1 Laser Safety
EN 61326-1 Electromagnetic Emissions and Susceptibility
2
Warning
• Do not stare into laser beam.
• Do not point laser directly at eye or indirectly off reective surfaces.
• For use by competent persons only.
• Do not point laser directly at eye or indirectly off reective surfaces.
• Replace the batteries as soon as the low-battery indicator appears.
• Verify the Tester’s operation by measuring on a known voltage source. Do
not use the thermometer if it operates abnormally.
• Do not operate the thermometer around explosive gas, vapor, or dust.
• To avoid a burn hazard or re, know that reective objects may be much
hotter than the indicated temperature reading.
• Do not leave the thermometer on or near objects of high temperature.
• If the thermometer is used in a manner not specied by this manual,
the protection provided by the thermometer may be impaired or may
result in hazardous laser radiation exposure.
Cautions
To avoid damaging the thermometer under measurement, protect them
from the following:
• EMF (electro-magnetic elds) from arc welders, induction heaters
• Static electricity
• Thermal shock (caused by large or abrupt ambient temperature changes —
allow 30 minutes for instrument to stabilize before use)
• Do not leave the thermometer on or near objects of high temperature
UNPACKING AND INSPECTION
Your shipping carton should include:
1 Thermometer (IR-712 or IR-720 or IR-730)
1 Carrying bag
1 9V battery (installed)
1 Users manual
If any of the items are damaged or missing, return the complete package to
the place of purchase for an exchange.
3
FEATURES
The Amprobe IR-712, a 12:1 spot to distance ratio infrared thermometer, offers
best in class accuracy and response time with a temperature measurement
range of 0°F to 1022°F or -18°C to 550°C. The IR-712 is specifically designed
for HVAC/R, electrical, industrial maintenance, automotive as well as quality
control and fire prevention applications.
• 12:1 Distance to Spot Ratio
• Temp Range of 0°F to 1022°F or -18°C to 550°C
• Precision accuracy and rapid response time
• Laser pointer, backlit dual LCD Display
• Auto display hold and MAX/MIN memory
• Adjustable emissivity for measuring a variety of materials
The Amprobe IR-720, a 20:1 spot to distance ratio infrared thermometer, offers
best in class accuracy and response time with a temperature measurement
range of -26°F to 1922°F or -32°C to 1050°C. The IR-720 is specifically designed
for HVAC/R, electrical, industrial maintenance, automotive as well as quality
control and fire prevention applications.
• 20:1 Distance to Spot Ratio
• Temp Range of -26°F to 1922°F or -32°C to 1050°C
• Precision accuracy and rapid response time
• Laser pointer, backlit dual LCD Display
• Auto display hold and MAX/MIN memory
• Adjustable emissivity for measuring a variety of materials
The Amprobe IR-730, a 30:1 spot to distance ratio infrared thermometer, offers
best in class accuracy and response time with a temperature measurement
range of -26°F to 2282°F or -32°C to 1250°C. The IR-730 is specifically designed
for HVAC/R, electrical, industrial maintenance, automotive as well as quality
control and fire prevention applications.
• 30:1 Distance to Spot Ratio
• Temp Range of -26°F to 1922°F or -32°C to 1050°C
4