Amprobe HD160C Specifications

Key features:
N10140
Measures 1500 VDC
CAT IV 1000 V
IP67 Rated
Temperature, Frequency
& Capacitance
Magne-Grip™ holster
with magnetic hanging strap
No hassle warranty
No waiting.
Data Sheet
HD160C
Heavy-Duty Digital Multimeter
Rugged autoranging meter with true-rms
Highest voltage capability,
measuring to 1500 Vdc and 1000 Vac
CAT IV 1000 V rated
Special sealing for environment
and water resistance. IP67 rated
Constructed with drop-resistant
housing and PCB mounting
Measures capacitance,
temperature and frequency
Superior 10,000 count resolution
with bar graph
Magne-Grip™ holster, frees both
hands for work
Includes high voltage test leads
with threaded alligator clips
Temperature measurement built-in
Frequency and capacitance
Digi-Glo™ bright backlight
No shipping charges.
Our commitment to high-quality products and customer service is demonstrated by our industry exclusive “No Hassle” warranty. In the unlikely event that an Amprobe Test Tool requires warranty service, any of our local dealers are authorized to replace it, on the spot.
Amprobe® Test Tools
The HD160C is designed for profes­sional use in harsh environments. The meter is unusually rugged and reliable in everyday heavy use ap­plications. The meter is made using waterproof construction to prevent dirt, grime and moisture from enter­ing the case and causing inaccurate readings or damaging shorts. Built of tough, fire-retardant thermoplastic resistant to grease and chemical spills, with all sensi­tive components shock-mounted for a drop resistance to at least eight feet. Model HD160C has an extended voltage measurement capability of 1500 V dc and 1000 V ac, unmatched by any other line of digital multime­ters. The extended voltage ranges can withstand transients up to 12 kV.
HD160C
www.Amprobe.com
HD160C Technical Specifications
Data Sheet
General Specifications
Display 4 digit LCD, 9999 counts, with annunciators, menu features and 41 segment bargraph. Polarity Indication Automatic Input overload indication OL, -OL.
Low Battery Indication B; less than 50 hours battery life remain, accuracy is no longer guaranteed Display Update Rate 2/sec, nominal; 20/sec for bargraph. Oper. Temp. 0 °C to +50 °C @ 0 to 75 % R.H. Storage Temp. -20 °C to 60 °C @ 0 to 80 % RH, battery removed Altitude 2000 meters - indoor use Temperature coefficient 0.1 x (spec. accuracy)/°C (0 °C to 18 °C and 28 °C to 50 °C) Fuse F 2 A/1500 V fuse (8 mm x 65 mm), I.R. 30 kA – Amprobe p/n FP700 Power Standard 9 -volt batter y, NEDA 1604, JIS 006P, IEC 6F22 Auto Power-Down Meter powers down after approximately 30 minutes of inactivity. Not in Min/Max function. Battery Life (typical) 150 hours, alkaline. Backlight usage consumes extra power and will decrease battery life significantly.
Dimensions, without holster (H x W x D) 200 x 102 x 59 mm (7.9 in x 4.0 in x 2.3 in)
Weight (incl. battery) 642 g (22 oz) Accessories Heavy Duty CAT IV 1000 V Test leads with threaded alligator clips (TL1500), battery (installed), hex
Case material Reinforced, high-impact, fire retardant thermoplastic Safety Meets EN 61010-1 CAT IV 1000 V (1500 V DC max) Class II, EN 60529:IP67CAT IV 1000 V (1500 V DC max) Class II, EN 60529:IP67 EMC Meets EN 61326-1
Backlight auto-off after approx. 60 seconds.
wrench (inside holster), Holster with Magne-Grip strap, Type K thermocouple probe (TP255), Tempera­ture Adaptor (TA-1A) and User Manual.
Electrical Specifications (Accuracy at 23 °C ± 5 °C, <75 % RH, guaranteed for one year.)
Function Range Accuracy
DC Volts
Ranges 1000 mV, 10 V, 100 V, 1500 V Resolution 0.1 mV in 1000 mV range Accuracy ±(0.1 % rdg + 5 dgt) Input Impedance 10 M CMRR >120 dB up to 1500 V dc NMRR >60 dB at 50 or 60 Hz OL Protection 1500 V dc or 1000 V ac rms. Transient protection 12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000
AC Volts True rms
Ranges 1000 mV, 10 V, 100 V, 1000 V Resolution 0.1 mV in 1000 mV range Accuracy 1000 mV (45 Hz to 400 Hz) ± (1.2 % rdg + 10 dgt)
10 V, 100 V (45 Hz to 500 Hz) ± (1.2 % rdg + 10 dgt) 10 V, 100 V (500 Hz to 2 kHz) ± (2.0 % rdg + 10 dgt) 1000 V (45 Hz to 1 kHz) ± (2.0 % rdg + 10 dgt)
Input Impedance 10 M Conversion type True rms, ac coupled 5 % to 100 % of range Crest factor 3 OL Protection 1500 V dc or 1000 V ac rms Transient protection 12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V
V/1500V dc product. This product should not be used in installations where transients exceed 12 kV.
product. This product should not be used in installations where transients exceed 12 kV
Amprobe® Test Tools
Loading...
+ 2 hidden pages