Amprobe HD110C Specifications

Key features:
N10140
Measures 1500 VDC
CAT IV 1000 V
IP67 Rated
Magne-Grip™ holster
with magnetic hanging strap
No hassle warranty
No waiting.
No shipping charges.
Our commitment to high-quality products and customer service is demonstrated by our industry exclusive “No Hassle” warranty. In the unlikely event that an Amprobe Test Tool requires warranty service, any of our local dealers are authorized to replace it, on the spot.
Data Sheet
HD110C
Heavy-Duty Digital Multimeter
Highest voltage capability,
measuring to 1500 V dc and 1000 V ac
CAT IV 1000 V rated
Special sealing for environment
and water resistance. IP67 rated
Constructed with drop-resistant
housing and PCB mounting
Magne-Grip™ holster, frees both
hands for work
Includes high voltage test leads
with threaded alligator clips
The HD110C is designed for profes­sional use in harsh environments. The meter is unusually rugged and reliable in everyday heavy use ap­plications. The meter is made using waterproof construction to prevent dirt, grime and moisture from enter­ing the case and causing inaccurate readings or damaging shorts. Built of tough, fire-retardant thermoplastic resistant to grease and chemical spills, with all sensitive components shock-mounted for a drop resistant to at least eight feet. HD110C has an extended voltage measurement capability of 1500 V dc and 1000 V ac, unmatched by any other line of digital multimeters. The extended voltage ranges can withstand transients up to 12 kV.
HD110C
Amprobe® Test Tools
www.Amprobe.com
HD110C Technical Specifications
Data Sheet
General Specifications
Display 3-1/2 digit LCD, 1999 counts, with annunciators and menu features Polarity Indication Automatic Input overload indication 1 Low Battery Indication B; < 50 hours battery life remain, accuracy is no longer guaranteed Display Update Rate 2.5/sec, nominal Oper. Temp. 0 °C to +50 °C, (< 75 % R.H.) Storage Temp -20 °C to 60 °C, 0 to 80 % RH, battery removed Temperature coefficient 0.1 x (spec. accuracy)/°C (0 ° to 18 °C and 28° to 50 °C) all functions and ranges except for mVDC
0.3 x (spec. accuracy)/°C (0 ° to 18 °C and 28° to 50 °C) for mVDC Altitude Up to 2000 m — indoor use Fuse F 2 A/1500 V fuse (8 mm x 65 mm), I.R. 30 kA – Amprobe p/n FP700 Power Standard 9 V battery, NEDA 1604, JIS 006P,IEC 6F22 Auto Power-Down Meter powers down after approx. 30 min. of inactivity. Battery Life 250 hours typical with carbon-zinc, 500 hours typical with alkaline Dimensions, with holster
(H x W x D) 200 x 102 x 59 mm (7.9 in x 4.0 in x 2.3 in) Weight (incl. battery) 642 g (20 oz) Accessories Heavy Duty CAT IV 1000 V Test leads with threaded alligator clips (TL1500), battery (in instrument), hex
Case material Flame retardant, high-impact thermoplastic Safety Meets EN 61010-1 CAT IV 1000 V (1500 V DC max) Class II, EN 60529:IP67CAT IV 1000 V (1500 V DC max) Class II, EN 60529:IP67 EMC Meets EN 61326-1
wrench in holster, Magne-Grip flex strap and User Manual
Electrical Specifications (Accuracies at 23 °C ± 5 °C, <75 % RH non- condensing, guaranteed for one year.)
Function Range Accuracy
DC Volts
Ranges 200 mV, 2 V, 20 V, 200 V, 1500 V Resolution 0.1 mV Accuracy All ranges ±(0.1 % rdg+2 dgts) Input Impedance 10 M OL Protection 1500 V dc/1000 V ac rms Transient Protection 12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V
AC Volts (45 Hz to 2 kHz)
Ranges 200 mV, 2 V, 20 V, 200 V, 1000 V Resolution 0.1 mV Accuracy 200 mV to 200 V (45 -500 Hz) ±(0.8 % rdg+4 dgts)
200 mV to 200 V (500 Hz-2 kHz) ±(1.5 % rdg+5 dgts) 1000 V (50-60 Hz) ±(0.8 % rdg+4 dgts) 1000 V (60-500 Hz) ±(1.5 % rdg+5 dgts)
Input Impedance 10 M OL Protection 1500 V dc/1000 V ac rms Transient Protection 12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V
DC Current
Ranges 200 µA, 2 mA, 20 mA, 200 mA, 2 A Resolution 0.1 µA Accuracy 200 µA to 20 mA ±(0.5 % rdg+2 dgts)
200 mA to 2 A ±(1.0 % rdg+2 dgts)
product. This product should not be used in installations where transients exceed 12 kV.
product. This product should not be used in installations where transients exceed 12 kV.
Amprobe® Test Tools
Loading...
+ 2 hidden pages