Amprobe HD110C, HD160C Catalog Page

HD110C and HD160C Heavy-duty Multimeters
Built for harsh environments, these unusually rugged meters offer extra features and superior protection that keep them operating reliably in heavy-duty applications. The meter's molded plastic case is made from flame-retardant thermoplastic to help protect against fire, chemicals, grease, falls, impacts, and abrasions.
• Measures up to 1500 V DC and 1000 V AC and withstands transients up to 12 kV (CAT IV 1000 V) – unmatched by other digital multimeters
• IP 67 rated and sealed to prevent dirt, grime and moisture from entering the case and causing inaccurate readings or damaging shorts
• Tough, fire-retardant thermoplastic resists grease and chemical spills and other environmental hazards
FEATURE HD110C HD160C
True-RMS
DC Voltage 200.0 mV, 2.000 V, 20.00 V, 200.0 V, 1500 V 1000.0 mV, 10.000 V, 100.00 V, 1500.0 V
AC Volt age 200.0 mV, 2.000 V, 20.00 V, 200.0 V, 1000 V 1000.0 mV, 10.000 V, 100.00 V, 1000.0 V
Current AC/DC
Resistance
Diode
Continuity
Frequency
Capacitance
Temperature -4˚F
INCLUDED ACCESSORIES: Test leads, batteries (installed), user manual, Magne-Grip™ holder with magnetic hanging strap, K-type thermocouple, threaded alligator clips
200.0 µA, 2.000 mA, 20.00 mA,
200.0 mA, 2.000 A
Ω
, 2.000 kΩ, 20.00 kΩ, 200.0 kΩ,
200.0
2.000 M
Ω
, 20.00 M
• All sensitive components are shock-mounted for drop resistance to at least eight feet
• Magne-Grip™ holder with magnetic hanging strap frees both hands for work
• Automatic polarity indication
• Superior 10,000 count resolution with bar graph
• Bright backlight for superior visibility
• Auto power-off to save batteries plus low battery indication
100.00 µA, 1000.0 µA, 10.000 mA,
Ω
1000.0 Ω, 10.00 kΩ, 100.00 kΩ,
Ω,
1000.0 k
100.00 Hz, 1000.0 Hz, 10.000 kHz,
100.00 kHz, 1000.0 kHz, 10.000 M Hz
10.000 MΩ, 40.00 M
40.00 nF, 400.0 nF, 4.000 µF,
40.00 µF, 400.0 µF
^ 2372˚F (-20˚C ^ 1300˚C)
Ω
HD160C
TOP R ATE D
“Great product with unlimited features”
“The HD160C-IP67 is a versatile instrument that allows me to carry just one instrument instead of several. Checking out panels, resistance and performing HVAC control wiring and trouble shooting, it is a hard instrument to beat. All of the electricians on my jobs and HVAC technicians carry the one versatile tester the Amprobe HD160C-IP67!”
- HD160C customer reviews
Digital Multimeters
Why You Need a True-RMS Reading Multimeter.
Answer: True-RMS instruments are accurate on any AC waveform. There are two basic AC measuring systems. One is "average sensing, RMS indicating." This is the most common system because it is affordable and easy to manufacture. An instrument with this type of measuring system measures the average of a sine wave, and then multiplies it by 1.112, allowing the instrument to indicate RMS. This measuring system is only accurate on sine waves.
The second measuring method is called "RMS Sensing, RMS Indicating." An instrument with this type of measuring system computes the RMS value of the measured waveform (sine or otherwise). This is referred to as "True-RMS" reading. This measuring system is accurate for any waveform. When an average sensing
instrument is used on a non-sinusoidal waveform, measurement accuracy could be off as much as 50%. Since you may not know what type of AC waveform you are measuring, a True-RMS instrument should be used whenever possible.
Recommended Accessories
DL248D Deluxe Test Leads Kit
(See Page 56)
CT235A Clamp Attachment CT237B Clamp Attachment CT238A Clamp Attachment
(See Page 56)
DL248D
CT235A, CT237B, CT238A
15