Automotive Multimeter
Model AU92 is a full featured multimeter that has additional measurement for automotive servicing. It offers a built-in thermometer to measure air, surface or immersion temperatures. The meter also tests engine RPM and dwell in addition to standard multimeter features of voltage, current, resistance and continuity. Perform accurate RPM measurements for 2- and 4-stroke automotive engines using the Inductive Pickup tool. A well designed tool for your automotive testing needs.
n Performs all standard electrical test for on-car and bench troubleshooting
n Tests engine RPM and dwell n Capacitance, Frequency and
Temperature n Measures DC/AC voltage, DC/AC
current, resistance, diodes and continuity beeper, duty cycle
n Accurate RPM measurements for 2- and 4-stroke automotive engines using the inductive probe
n Locate faulty wiring and components
n Data Hold button retains display data
n Protective holster with magnetic hanging strap
n Compact size n Includes inductive pick-up probe,
carrying case, test leads, test lead extender tips, threaded alligator clips, type k temperature probe, spare fuse
AU92
(note: $500 MSLP limit)
Amprobe® Test Tools
www.Amprobe.com
AU92 Automotive Multimeter
Specifications 23 °C ± 5 °C, < 75% R.H.
Function Range Accuracy
DC VOLTS
400 mV, 4 V, 40 V, 400 V, 600 V ±(1.0% rdg + 2 dgts) Resolution: 0.1 mV Input impedance: 400 mV: >100 M; 4 V:10 M; 40 V ~ 600 V: 9.1 M Overload protection: 600VDC or AC rms
AC VOLTS
400 mV, 4 V, 40 V, 400 V, 600 V 400 mV (50 ~ 100 Hz) ±(2.0% rdg + 5 dgts) 4, 40, 400, 600 V (50 ~ 500 Hz) ±(2.0% rdg + 5 dgts) Resolution: 0.1 mV Input impedance: 400 mV: >100 M; 4 V: 10 M; 40 V ~ 600 V: 9.1 M Overload protection: 600 VDC or AC rms
DC CURRENT
400 µA, 4000 µA, 40 mA, 400 mA, 10 A 400 µA to 400 mA ranges ±(2.0% rdg + 2 dgts) 10 A range ±(3.0% rdg + 3 dgts)
10A input: 10 A for 60 seconds maximum followed by a 10 minutes cooling period
Resolution: 0.1 µA Voltage burden: 0.2 V on 400uA , 40mA ranges
2V on 4000 uA, 400 mA ranges
Input protection: 0.5 A / 500V fast blow ceramic fuse (FP520)
10 A / 500 V fast blow ceramic fuse (FP540)
AC CURRENT (50-500 Hz)
400 uA, 4000 uA, 40 mA, 400 mA, 10 A 400 uA to 400 mA ranges ±(2.5% rdg + 5 dgts) 10 A range ±(3.5% rdg + 5 dgts)
10A input: 10 A for 60 seconds maximum followed by a 10 minutes cooling period
Voltage burden: see DC Current Input protection: see DC Current
RESISTANCE
400 , 4 k, 40 k, 400 k, 4 M, 40 M Resolution: 0.1 on 400 range 400 to 400 k ranges ±(1.5% rdg + 4 dgts) 4 M range ±(2.5% rdg + 4 dgts) 40 M range ±(5.0% rdg + 5 dgts) Open circuit volts: -0.45Vdc (-1.2Vdc on 400 range) Overload protection: 600 VDC or AC RMS
FREQUENCY (Hz) (Auto ranging)
4 kHz, 40 kHz, 400 kHz Resolution: 1Hz ±(0.1% rdg + 3 dgts) Sensitivity: 10Hz ~ 400kHz: > 3.5Vrms Minimum pulse width: > 2.5us Duty cycle limits: >30% and < 70% Overload protection: 600 VDC or AC RMS