AMP-300 Series
Motor Maintenance TRMS Clamp Meters
The Modern Evolution of the Professional Clamp Meter
Amprobe’s AMP-300 Series True-RMS Clamp Meters offer a complete range of measuring functions for modern industrial environments, motor testing and HVAC applications.
All models feature True-RMS sensing, low pass lters and fast response processors for
quick, error-free measurements. The Amp-Tip function allows for precise measurement of current down to the tenth of an Amp, and a third input jack enables motor rotation and 3-phase sequence testing.
AMP-300 Series Features
• True-RMS
• Motor Testing Capabilities
- 3-phase sequence testing
- Inrush current monitoring during motor start-up
• HVAC Features
- Temperature measurement; User selectable °F or °C
- DC Microamps for flame sensor testing
- Capacitance measurement for start and run motor capacitors
• Amp-Tip Function
• Low Pass Filter for variable
frequency drives
• Safety Rated:
CAT III 600 V (AMP-310, AMP-320) CAT IV 600 V, CAT III 1000 V (AMP-330)
AMP-310
AC Clamp Meter HVAC
AMP-320
AC/DC Clamp Meter Electrical Motor Maintenance
AMP-330
AC/DC 1000 A Clamp Meter Industrial Motor Maintenance
©2014 Amprobe® For detailed specications and ordering go to www.Amprobe.com 6003578 BAmprobe® | [email protected] | Fluke Corporation, Everett, WA 98203 | Tel: 877-AMPROBE (267-7623)
Page 2
AMP-300 Series Product Details
True-RMS
for accurate voltage
Non-contact voltage detection (NCV)
measurements in noisy environments.
Audible continuity and diode test
Low pass lter
for current and voltage measurements on variable
Data hold, relative zero, MAX/MIN/AVG mode
frequency drives.
Large LCD backlit
Amp-Tip function
display
for precise low-current measurement of small diameter wires down to 0.1 Amp to help with electrical system troubleshooting.
Safety rated
CAT III 600 V
(AMP-310, AMP-320)
CAT IV 600 V CAT III 1000 V
(AMP-330)
AMP-300 Series Applications
• Accurate measurement of current, voltage and frequency on all
electrical systems including distorted, non-sinusoidal signals (True-RMS function) and variable frequency drives
(low pass lter).
• Capacitance measurement for start
and run motor capacitors.
• Resistance and continuity functions to verify quality of electrical connections and to check if motor and transformer coils
are working properly.
• 3-phase Motor and Phase Rotation Tests allow proper connection of a
motor to a 3-phase system. Improperly
connected motors will spin in a reverse direction, which may destroy the motor
or equipment connected to it.
• Low Pass lter allows measurement of current and voltage on variable frequency drives (motors with speed controlled by
frequency). Without this feature, the
meter would provide erroneous readings
when measuring voltage and current.
Measurements:
Model AMP-310 AMP-320 AMP-330
Safety Rating
Voltage AC Current DC Current
Frequency Resistance
Capacitance
Temperature
CAT III 600 V CAT III 600 V
Up to 600 V AC/DC Up to 600 V AC/DC Up to 1000 V AC/DC
Up to 600 A Up to 600 A Up to 1000 A
– Up to 600 A Up to 1000 A
5 to 999 Hz
0 to 60 kΩ
0.0 to 2500 µF
• • •
CAT IV 600 V
CAT III 1000 V
• DC Microamps output for measurement
of ame sensors. Test the proper operation of the ame sensor safety system in gas appliances. A broken
sensor in a gas appliance will prevent the safety valve from opening and the
appliance will not work.
• Inrush current measurement for motor start-up monitoring, allowing users to verify that the motor is receiving the required inrush current to support proper
motor start.
AMP-310
AC Clamp Meter HVAC
AMP-320 AC/DC Clamp Meter
Electrical Motor Maintenance
AMP-330 AC/DC 1000 A Clamp Meter
Industrial Motor Maintenance
©2014 Amprobe® For detailed specications and ordering go to www.Amprobe.com 6003578 BAmprobe® | [email protected] | Fluke Corporation, Everett, WA 98203 | Tel: 877-AMPROBE (267-7623)
Page 3
AMP-200 and AMP-300
Detailed Specifications
Model AMP-210 AMP-220 AMP-310 AMP-320 AMP-330
Safety Rating
Jaw Opening
AC Voltage (True-RMS)
DC Voltage
AC+DC Voltage
AC Current (True-RMS)
DC Current
AC+DC Current
Precise Low Current AC
Precise Low Current DC
Precise Low Current AC+DC
Frequency
Resistance
Capacitance
Continuity Beeper
Non-Contact Voltage
True-RMS Low Pass Filter Autoranging Relative Zero
MAX/MIN/AVG
Diode Test
Data Hold
Backlight
Auto Power Off
300 Series:
DC Microamps
Temperature*
(Type K thermocouple)
*Error does not include Type-K thermocouple errors
3-Phase and Motor Rotation Indication
Inrush Current
Peak Hold (Crest)
Work Light
AC Clamp Meter
Electrical
CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT IV 600 V, CAT III 1000 V
1.18 in (30 mm) 1.37 in (35 mm) 1.18 in (30 mm) 1.37 in (35 mm) 2.0 in (51 mm)
Range: 0 to 600.0 V
Accuracy: ±1.0% + 5LSD (50 to 60 Hz)
Range: 0 to 600.0 V
Accuracy: ±1.0% + 5LSD
–
Range: 0 to 600.0 A
Accuracy: ±1.8% + 5LSD (50 to 100 Hz)
±2.0% + 5LSD (100 to 400 Hz)
–
–
Range: 0 to 60.00 A
Accuracy: ±1.5% + 5LSD (50 to 60 Hz)
–
–
Range: 5.00 to 999.9 Hz
Accuracy: ±1.0% + 5LSD (600 V range)
Range: 50.0 to 400.0 Hz
Accuracy: ±1.0% + 5LSD (600 A range)
Range: 0.0 to 60.00 kΩ
Accuracy: ±1.0% + 5LSD
Range: 0.0 to 2500 µF
Accuracy: ±2.0% + 4LSD
10V to 1000V AC, 50/60Hz 10V to 1000V AC, 50/60Hz
• • • • •
• • • • •
• • • • •
• • • • •
• • • • •
• • • • •
• • • • •
• • • • •
• • • • •
– –
– –
– –
– –
– – – –
– – – –
AC/DC Clamp Meter
Electrical
Range: 0 to 600.0 V
Accuracy: 1.2% ± 7LSD (DC,
50 to 60 Hz)
Range: 0 to 600.0 A
Accuracy: ±2.0% + 5LSD
Range: 0 to 600.0 A
Accuracy: ±2.2% + 7LSD
(DC, 50 to 100 Hz)
±2.7% + 7LSD (100 to 400 Hz)
Range: 0 to 60.00 A
Accuracy: ±2.0% + 5LSD
Range: 0 to 60.00 A
Accuracy: ±2.0% + 5LSD
(DC, 50 to 60 Hz)
ON ≤ 10 Ω
OFF > 250 Ω
AC Clamp Meter
HVAC
AC/DC Clamp Meter
Electrical Motor
Maintenance
Range: 0 to 600.0 V
Accuracy: ±1.0% + 5LSD (50 to 60 Hz)
Range: 0 to 600.0 V
Accuracy: ±1.0% + 5LSD
Range: 0 to 600.0 V
–
Accuracy: ±1.8% + 5LSD (50 to 100 Hz)
±2.0% + 5LSD (100 to 400 Hz)
–
–
Accuracy: ±1.5% + 5LSD (50 to 60 Hz)
–
–
Range: 5.00 to 999.9 Hz
Accuracy: ±1.0% + 5LSD (600 V range)
Range: 50.0 to 400.0 Hz
Accuracy: ±1.0% + 5LSD (600 A range)
Accuracy: 1.2% ± 7LSD (DC, 50
to 60 Hz)
Range: 0 to 600.0 A
Range: 0 to 600.0 A
Accuracy: ±2.0% + 5LSD
Range: 0 to 600.0 A
Accuracy: ±2.2% + 7LSD
(DC, 50 to 100 Hz)
±2.7% + 7LSD (100 to 400 Hz)
Range: 0 to 60.00 A
Range: 0 to 60.00 A
Accuracy: ±2.0% + 5LSD
Range: 0 to 60.00 A
Accuracy: ±2.0% + 5LSD
(DC, 50 to 60 Hz)
Range: 0.0 to 60.00 kΩ
Accuracy: ±1.0% + 5LSD
Range: 0.0 to 2500 µF
Accuracy: ±2.0% + 4LSD
ON ≤ 10 Ω
OFF > 250 Ω
Range: 0.0 to 2000 µA
Accuracy: ±1.0% + 5LSD
Accuracy: -40.0 to 14.0°F (±1.0% +3.0°F), >14.0 to 99.9°F (±1.0% +1.5°F)
100 to 752°F (±1.0% +2°F), -40.0 to -10.0°C (±1.0% +1.5°C)
>-10.0 to 99.9°C (±1.0% +0.8°C), 100 to 400°C (±1.0% + 1°C)
Range: -40.0 to 752°F, -40.0 to 400°C
Rotation-R for mains supply
Rotation-M for motors
Accuracy: ±2.2% + 7LSD (DC, 40 to 100 Hz)
±1.5% + 5LSD (0.00 to 20.00 A, 40 to 100 Hz) ±2.0% + 5LSD (0.00 to 20.00 A, 100 to 400 Hz) ±3.0% + 5LSD (20.00 to 60.00 A, 40 to 100 Hz)
±3.0% + 5LSD (20.00 to 60.00 A, 100 to 400 Hz)
Accuracy: ±1.5% + 5LSD (0.00 to 20.00 A)
±2.0% + 7LSD (0.00 to 20.00 A, DC, 40 to 100 Hz)
±2.2% + 7LSD (0.00 to 20.00 A, 100 to 400 Hz)
±3.0% + 7LSD (20.00 to 60.00 A, DC, 40 to 100 Hz)
±3.0% + 7LSD (20.00 to 60.00 A, 100 to 400 Hz)
• • •
©2014 Amprobe® For detailed specications and ordering go to www.Amprobe.com 6003578 BAmprobe® | [email protected] | Fluke Corporation, Everett, WA 98203 | Tel: 877-AMPROBE (267-7623)
AC/DC 1000 A Clamp Meter
Industrial Motor Maintenance
Range: 0 to 1000 V
Accuracy: ±0.8% + 5LSD (50 to 60 Hz)
±1.5% + 5LSD (20 to 200 Hz)
±10% + 5LSD (200 to 400 Hz)
Range: 0 to 1000 V
Accuracy: ±0.8% + 5LSD
Range: 0 to 1000 V
Accuracy:
±1.0% + 7LSD (50 to 60 Hz)
±1.8% + 7LSD (DC, 40 to 200 Hz)
±12% + 7LSD (200 to 400 Hz)
Range: 0 to 1000 A
Accuracy:
±1.8% + 5LSD (40 to 100 Hz)
±2.2% + 5LSD (100 to 400 Hz)
Range: 0 to 1000 A
Accuracy: ±1.8% + 5LSD
Range: 0 to 1000 A
±2.5% + 7LSD (100 to 400 Hz)
Range: 0 to 60.00 A
Accuracy:
Range: 0 to 60.00 A
±3.0% + 5LSD (20.00 to 60.00 A)
Range: 0 to 60.00 A
Accuracy:
Range: 5.00 to 999.9 Hz
Accuracy: ±1.0% + 5LSD (1000 V range)
Range: 40.0 to 400.0 Hz
Accuracy: ±1.0% + 5LSD (1000 A range)
•
•
Page 4
AMP-200 and AMP-300
General Specifications
Model AMP-210 AMP-220 AMP-310 AMP-320 AMP-330
Display
Polarity
3-5/6 digits 6000 counts 3-5/6 digits 6000 counts 3-5/6 digits 6000 counts 3-5/6 digits 6000 counts 3-5/6 digits 6000 counts
Automatic Automatic Automatic Automatic Automatic
Update Rate
Operating Temperature
Relative Humidity
Operating Altitude
Pollution Degree
Storage Temperature
Temperature
Coefcient
Battery
EMC
Safety Compliance
Certication
5 per second nominal 5 per second nominal 5 per second nominal 5 per second nominal 5 per second nominal
32 to 104°F (0 to 40°C) 32 to 104°F (0 to 40°C)
80% at 30°C, 50% at 40°C
0 to 2000 m 0 to 2000 m
2
-4 to 140°F (-20°C to 60°C), < 80% RH
Nominal 0.15 x (specied
accuracy)/ °C @ (0°C to 18°C
or 28°C to 40°C)
Two AAA 1.5 V battery Two AAA 1.5 V battery Two AAA 1.5 V battery Two AAA 1.5 V battery Two AA 1.5 V battery
Meets EN 61326-1:2006 Meets EN 61326-1:2006 Meets EN 61326-1:2006 Meets EN 61326-1:2006 Meets EN 61326-1:2006
UL/IEC/EN 61010-1 ed. 3.0,
IEC/EN 61010-2-033 ed. 1.0,
CAN/CSA C22.2 NO. 61010-1
ed. 3.0, IEC/EN 61010-2-032 ed. 3.0 & IEC/EN 61010-031
ed. 1.1
UL (c/us) and CE UL (c/us) and CE UL (c/us) and CE UL (c/us) and CE UL (c/us) and CE
80% at 30°C, 50% at 40°C
2 2
-4 to 140°F (-20°C to 60°C), < 80% RH
Nominal 0.15 x (specied
accuracy)/ °C @ (0°C to 18°C
or 28°C to 40°C)
UL/IEC/EN 61010-1 ed. 3.0,
IEC/EN 61010-2-033 ed. 1.0,
CAN/CSA C22.2 NO. 61010-1
ed. 3.0, IEC/EN 61010-2-032 ed. 3.0 & IEC/EN 61010-031
ed. 1.1
32 to 104°F (0 to 40°C) 32 to 104°F (0 to 40°C)
80% at 30°C, 50% at 40°C 80% at 30°C, 50% at 40°C
0 to 2000 m
-4 to 140°F (-20°C to 60°C), < 80% RH
Nominal 0.15 x (specied
accuracy)/ °C @ (0°C to 18°C
or 28°C to 40°C)
UL/IEC/EN 61010-1 ed. 3.0,
IEC/EN 61010-2-033 ed. 1.0,
CAN/CSA C22.2 NO. 61010-1
ed. 3.0, IEC/EN 61010-2-032 ed. 3.0 & IEC/EN 61010-031
ed. 1.1
0 to 2000 m 0 to 2000 m
2
-4 to 140°F (-20°C to 60°C), < 80% RH
Nominal 0.15 x (specied
accuracy)/ °C @ (0°C to 18°C or
28°C to 40°C)
UL/IEC/EN 61010-1 ed. 3.0, IEC/
EN 61010-2-033 ed. 1.0, CAN/CSA
C22.2 NO. 61010-1 ed. 3.0, IEC/
EN 61010-2-032 ed. 3.0 & IEC/EN
61010-031 ed. 1.1
14 to 122°F (-10 to 50°C)
Non condensing at ≤10°C
90% at 10 to30°C 75% at 30 to 40°C 45% at 40 to 50°C
2
-4 to 140°F (-20°C to 60°C), < 80% RH
Nominal 0.10 x (specied accuracy)/ °C @ (0°C
to 18°C or 28°C to 50°C)
UL/IEC/EN 61010-1 ed. 3.0, IEC/EN 61010-2-033
ed. 1.0, CAN/CSA C22.2 NO. 61010-1 ed. 3.0,
IEC/EN 61010-2-032 ed. 3.0 & IEC/EN 61010-
031 ed. 1.1
Dimensions (L x W x H):
Weight:
8.62 x 3.03 x 1.46 in (219 x 77 x 37 mm)
208 g (0.46 lb) 254 g (0.56 lb) 208 g (0.46 lb) 254 g (0.56 lb) 420 g (0.93 lb)
8.82 x 3.03 x 1.46 in (224 x 77 x 37 mm)
Accessories
Included:
User’s Manual
Test Leads
Carrying Case
Batteries
Alligator Clip Set
Banana plug K-type Thermocouple
• • • • •
• • • • •
• • • • •
AAA (2) AAA (2) AA (2)
– –
– –
Amprobe®
[email protected] Fluke Corporation, Everett, WA 98203 Tel: 877-AMPROBE (267-7623)
For complete information about Amprobe test tools, visit www.Amprobe.com
8.62 x 3.03 x 1.46 in (219 x 77 x 37 mm)
8.82 x 3.03 x 1.46 in (224 x 77 x 37 mm)
10.16 x 3.70 x 1.73 in (258 x 94 x 44 mm)
• • •
• • •
© 2014 Amprobe | Specications subject to change without notice. Printed In U.S.A. 6003578 B