AMPROBE ACDC-400, ACDC-400A Service Manual

ACDC-400 400A AC/DC Clamp-on Multimeter
CAT
z
600V
Form and function. This versatile clamp-on instrument incor­porates the features desired for testers in its price range.
• AC/DC Current up to 400A
• AC/DC Voltage up to 600V
• Resistance measurement
• Continuity test
• Data Hold
• MAX / MIN recording
• Backlight
• Analog bar graph
• Auto or Manual range selection
• Low battery indication
• Accommodates conductors up to 1.18" (30mm) in diameter
FEATURES RANGE & RESOLUTION* ACCURACY
DC Voltage AC Voltage
AC / DC Current
Resistance
OPTIONAL ACCESSORIES PART NUMBER
Line Splitter (Energizer) A47L 3000A AC Flexible Clamp-on Attachment ACF-3000 AK Single Input Thermocouple Temperature Attachment Alligator Clips (For test leads) VRC-320
REPLACEMENT PARTS (supplied with product) PART NUMBER
Test lead holder MTL-CAP Carrying case SV-U Test leads with set of alligator clips (alligator clips are not supplied with product) MTL-90B
400.0 mV / 4.000 / 40.00 / 400.0 / 600 V +/-(1.0% Rdg + 2 LSD)
400.0 mV ±(1.0%Rdg + 50 LSD)
4.000 / 40.00 / 400.0 / 600 V
40.00 / 400.0 A +/-(2% Rdg + 10 LSD)
400.0 Ohms, 4.000 / 40.00 / 400.0 k
4.000 / 40.00 M
+/-(1.2% Rdg + 3 LSD)
@ 50-60 Hz +/-(1% Rdg + 5 LSD)
+/-(3% Rdg + 3 LSD)
TMA-K
www.AMPROBE.com
ACDC-400 400A AC/DC Clamp-on Multimeter
SPECIFICATIONS
Safety
Comply with: EN 61010 Insulation: Class 2, double reinforced insulation Pollution: Level 2 For inside use, max height: 2000m Over voltage: CAT III 600V
General Data
Mechanical Characteristics:
Size: 205(L) x 64 (W) x 39(H)mm Weight (including battery): about 280g Jaws opening: 30mm Max conductor size: 30mm
Supply:
Batteries type: 2 batteries 1.5V LR03 AAA. Low battery indication: Symbol " " is displayed when battery
Battery life: About 25 hours. Display Characteristics: 3 _ LCD w/ maximum reading 3999 units
Sample rate: 2 times/sec.
Conversion mode: mean value
(between ground & input terminal)
level is too low.
plus decimal point signs plus backlight
20 times/sec. for analogical bargraph
ENVIRONMENTAL CONDITIONS
Climatic Conditions:
Reference temperature: 23° ± 5°C Operating temperature: 5 ÷ 40 °C Operating humidity: <80% RH Storage temperature: -10 ÷ 60 °C Storage humidity: <80% RH
EMC
This apparatus was designed in accordance with EMC standards in force and its compatibility has been tested in accordance EN61326 (1997) + A1 (1998) + A2 (2001).
ACCESSORIES
CAT
z
600V
Standard Accessories:
The accessories contained inside the packaging are the following:
• Instrument
• Test leads (MTL-90B)
• Rubber test lead holster (MTL-CAP)
• User’s manual (www.Amprobe.com)
• Carrying case (SV-U)
• Batteries
Miramar, FL 33025 • Toll Free: 800-327-5060 • Phone: 954-499-5400 • Fax: 954-499-5418 • www.Amprobe.com
www.AMPROBE.com